{"product_id":"rm35lm33mw","title":"RM35LM33MW Schneider","description":"\u003cp\u003eThis Harmony RM35-LM relay allows monitoring of level control in 3-phase networks. This modular multi function 3-phase liquid level control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eHarmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eLevel control relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eLevel control relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay name\u003c\/td\u003e\n\u003ctd\u003eRM35L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay monitored parameters\u003c\/td\u003e\n\u003ctd\u003eDetection by resistive probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003etime delay\u003c\/td\u003e\n\u003ctd\u003eAdjustable 0.1...5 s, +\/- 10 % Tt- time delay upon fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching capacity in VA\u003c\/td\u003e\n\u003ctd\u003e1250 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e10 mA 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum switching current\u003c\/td\u003e\n\u003ctd\u003e5 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epower consumption\u003c\/td\u003e\n\u003ctd\u003e5 VA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e250 Ohm...1 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-12 IEC 60947-5-1\u003cbr\u003eAC-13 IEC 60947-5-1\u003cbr\u003eAC-14 IEC 60947-5-1\u003cbr\u003eAC-15 IEC 60947-5-1\u003cbr\u003eDC-12 IEC 60947-5-1\u003cbr\u003eDC-13 IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContacts type and composition\u003c\/td\u003e\n\u003ctd\u003e2 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset time\u003c\/td\u003e\n\u003ctd\u003e1750 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum switching voltage\u003c\/td\u003e\n\u003ctd\u003e250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Un] rated nominal voltage\u003c\/td\u003e\n\u003ctd\u003e24...240 V AC\/DC 50\/60 Hz, non self-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage limits\u003c\/td\u003e\n\u003ctd\u003e20.4â¦264 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoperating voltage tolerance\u003c\/td\u003e\n\u003ctd\u003e- 15 % + 10 % Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epower consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput contacts\u003c\/td\u003e\n\u003ctd\u003e2 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal output current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edelay at power up\u003c\/td\u003e\n\u003ctd\u003e0.6 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 % of the full scale value\u003cbr\u003e+\/- 20 % for the HS range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeat accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 2 % time delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement error\u003c\/td\u003e\n\u003ctd\u003e0.5 %\/Â°C with temperature variation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity scale\u003c\/td\u003e\n\u003ctd\u003e0.25...5 kOhm LS (Low Sensitivity)\u003cbr\u003e5...100 kOhm St (Standard Sensitivity)\u003cbr\u003e50...1000 kOhm HS (High Sensitivity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity adjustment\u003c\/td\u003e\n\u003ctd\u003e5â¦100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum supply current for sensors\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable capacitance\u003c\/td\u003e\n\u003ctd\u003e1 nF HS (High Sensitivity) probe cable\u003cbr\u003e2.2 nF St (Standard Sensitivity) probe cable\u003cbr\u003e4.7 nF LS (Low Sensitivity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE : 73\/23\/EEC\u003cbr\u003eCE : EMC 89\/336\/EEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 500 MOhm 500 V DC between supply and relay output IEC 60255-5\u003cbr\u003e\u0026gt; 500 MOhm 500 V DC between measurement and relay output IEC 60664-1\u003cbr\u003e\u0026gt; 1 MOhm 500 V DC between supply and measurement IEC 60255-5\u003cbr\u003e\u0026gt; 500 MOhm 500 V DC between supply and relay output IEC 60664-1\u003cbr\u003e\u0026gt; 500 MOhm 500 V DC between measurement and relay output IEC 60255-5\u003cbr\u003e\u0026gt; 1 MOhm 500 V DC between supply and measurement IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e250 V IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating position\u003c\/td\u003e\n\u003ctd\u003eAny position without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, 1 x 0.5...1 x 4 mmÂ² AWG 20...AWG 11) solid without cable end\u003cbr\u003eScrew terminals, 2 x 0.5...2 x 2.5 mmÂ² AWG 20...AWG 14) solid without cable end\u003cbr\u003eScrew terminals, 2 x 0.2...2 x 1.5 mmÂ² AWG 24...AWG 16) flexible with cable end\u003cbr\u003eScrew terminals, 1 x 0.2...1 x 2.5 mmÂ² AWG 24...AWG 12) flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e5.3â¦8.9 lbf.in (0.6â¦1 N.m) IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003eLED (yellow) for relay ON\u003cbr\u003eLED (green) for power ON\u003cbr\u003eLED (yellow) for timer ON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003e35 mm symmetrical DIN rail conforming to IEC 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e100000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e30000000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating rate\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 360 operations\/hour full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e0.25...1000 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability data\u003c\/td\u003e\n\u003ctd\u003eB10d = 170000\u003cbr\u003eMTTFd = 182.6 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Type\u003c\/td\u003e\n\u003ctd\u003eWithout test button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840797790430,"sku":"RM35LM33MW-Sealed","price":150.84,"currency_code":"USD","in_stock":true},{"title":"Never Used Surplus","offer_id":46667373084894,"sku":"RM35LM33MW","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Used","offer_id":46667373150430,"sku":"RM35LM33MW-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_2be9b5f1-1702-48bc-8897-707c77a77f94.png?v=1753949011","url":"https:\/\/plc-direct.com\/products\/rm35lm33mw","provider":"PLC Direct","version":"1.0","type":"link"}