{"product_id":"nu-ep1","title":"NU-EP1 Keyence","description":"\u003ch2 class=\"prd-utility-heading-3 prd-utility-marginBottom-7\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"prd-specsTable prd-utility-focusRing is-overflowing\" tabindex=\"0\" data-controller=\"horizontal-scroll-state scroll-to-coord\" data-action=\"resize@window-\u0026gt;horizontal-scroll-state#setOverflowing scroll-\u0026gt;horizontal-scroll-state#setScrolled\" data-horizontal-scroll-state-target=\"container\" data-horizontal-scroll-state-overflowing-class=\"is-overflowing\" data-horizontal-scroll-state-has-scrolled-class=\"is-hasScrolled\" data-scroll-to-coord-target=\"container\"\u003e\n\u003cdiv class=\"prd-utility-body-small\"\u003e\n\u003cdiv class=\"specTable-block\"\u003e\u003ctable class=\"specTable-stibo-3282397\"\u003e\u003ctbody\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"key_att_1001\" colspan=\"4\"\u003e\u003cp\u003eModel\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"key_att_1001\"\u003e\u003cp\u003eNU-EP1\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2435\" colspan=\"4\"\u003e\u003cp\u003eName\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2435\"\u003e\u003cp\u003eCommunication unit that supports EtherNet\/IP™\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2436\" rowspan=\"5\"\u003e\u003cp\u003eEthernet\u003cbr\u003eSpecifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2436\" colspan=\"3\"\u003e\u003cp\u003eCompliant standards\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2436\"\u003e\u003cp\u003eIEEE802.3 (10BASE-T), IEEE802.3u (100BASE-TX), IEEE802.3af (Power over Ethernet, Class 3)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2437\" colspan=\"3\"\u003e\u003cp\u003eTransmission rate\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2437\"\u003e\u003cp\u003e10 Mbps (10BASE-T), 100 Mbps (100BASE-TX)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2438\" colspan=\"3\"\u003e\u003cp\u003eTransmission media\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2438\"\u003e\u003cp\u003eSTP or category 3 or higher UTP (10BASE-T),\u003csup\u003e*1\u003c\/sup\u003e STP or category 5 or higher UTP (100BASE-TX)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2439\" colspan=\"3\"\u003e\u003cp\u003eMaximum cable length\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2439\"\u003e\u003cp\u003e100 m \u003cspan class=\"prd-utility-color-inch\"\u003e328.1'\u003c\/span\u003e (the length between this unit and the Ethernet switch)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2440\" colspan=\"3\"\u003e\u003cp\u003eMax. number of connection stages\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2440\"\u003e\u003cp\u003e4 (10BASE-T) 2 (100BASE-TX)\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2458\" rowspan=\"6\"\u003e\u003cp\u003eEtherNet\/IP™\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2458\" colspan=\"3\"\u003e\u003cp\u003eCompliant functions\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2458\"\u003e\u003cp\u003eCyclic communication (implicit messages), message communication (explicit messages)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2459\" colspan=\"3\"\u003e\u003cp\u003eNumber of connections\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2459\"\u003e\u003cp\u003e64\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2460\" colspan=\"3\"\u003e\u003cp\u003eRPI (Transmission cycle)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2460\"\u003e\u003cp\u003e0.5 to 10,000 ms (in units of 0.5 ms)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2461\" colspan=\"3\"\u003e\u003cp\u003eTolerable communication bandwidth for cyclic communication\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2461\"\u003e\u003cp\u003e6,000 pps\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2462\" colspan=\"3\"\u003e\u003cp\u003eMessage communication\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2462\"\u003e\u003cp\u003eSupports UCMM, Class 3\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2463\" colspan=\"3\"\u003e\u003cp\u003eConformance test\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2463\"\u003e\u003cp\u003eSupports version A7\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2464\" rowspan=\"5\"\u003e\u003cp\u003eSensor connection\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2464\" colspan=\"3\"\u003e\u003cp\u003eConnectable sensors\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2464\"\u003e\u003cp\u003eSensor amplifier that supports N-bus\u003csup\u003e*3\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2465\" colspan=\"3\"\u003e\u003cp\u003eNumber of connectable units\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2465\"\u003e\u003cp\u003e16 maximum\u003csup\u003e*4\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2466\" colspan=\"3\"\u003e\u003cp\u003ePower supply\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2466\"\u003e\u003cp\u003ePower is supplied by this unit through the sensor amplifier connection connector.\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2467\" colspan=\"3\"\u003e\u003cp\u003eAllowable passing current\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2467\"\u003e\u003cp\u003eTotal: 1,200 mA or less\u003csup\u003e*5\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2468\" colspan=\"3\"\u003e\u003cp\u003ePower during PoE power receiving\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2468\"\u003e\u003cp\u003eSupply voltage: 24 V ±10 %, supply current: 360 mA or less\u003csup\u003e*6\u003c\/sup\u003e (UL Class 2)\u003csup\u003e*7\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2479\" colspan=\"4\"\u003e\u003cp\u003eIndicator lamp\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2479\"\u003e\u003cp\u003eLink\/activity indicator (LINK\/ACT): green LED, module status indicator (MS): 2-color (green and red) LED, network status indicator (NS): 2-color (green and red) LED, sensor communication indicator (N-bus): 2-color (green and red) LED\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2480\" colspan=\"4\"\u003e\u003cp\u003ePower voltage\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2480\"\u003e\u003cp\u003e24 VDC ±10 %, ripple (P-P): 10 % or less (when using the power supply connector); 48 VDC (57 V maximum; during PoE power receiving)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2481\" colspan=\"4\"\u003e\u003cp\u003ePower consumption\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2481\"\u003e\u003cp\u003e1,500 mW or less (60 mA or less at 24 V)\u003csup\u003e*8\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_1110\" rowspan=\"4\"\u003e\u003cp\u003eEnvironmental resistance\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_1110\" colspan=\"3\"\u003e\u003cp\u003ePollution degree\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_1110\"\u003e\u003cp\u003e2\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_43\" colspan=\"3\"\u003e\u003cp\u003eAmbient temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_43\"\u003e\u003cp\u003e-20 to +55 °C \u003cspan class=\"prd-utility-color-inch\"\u003e-4 to 131 °F\u003c\/span\u003e (No freezing)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_44\" colspan=\"3\"\u003e\u003cp\u003eRelative humidity\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_44\"\u003e\u003cp\u003e35 to 85 % RH (No condensation)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_90\" colspan=\"3\"\u003e\u003cp\u003eVibration resistance\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_90\"\u003e\u003cp\u003e10 to 55 Hz, Double amplitude 1.5 mm \u003cspan class=\"prd-utility-color-inch\"\u003e0.06\"\u003c\/span\u003e, 2 hours in each of the X, Y, and Z directions\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_131\" colspan=\"4\"\u003e\u003cp\u003eMaterial\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_131\"\u003e\u003cp\u003eMain unit case and dust cover: polycarbonate, power supply connector: polyamide (plug), PBT (socket)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2488\" colspan=\"4\"\u003e\u003cp\u003eAccessories\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2488\"\u003e\u003cp\u003eInstruction manual, power supply connection connector, end unit x 2\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_113\" colspan=\"4\"\u003e\u003cp\u003eWeight\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_113\"\u003e\u003cp\u003eApprox. 80 g (including connectors)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-foot\"\u003e\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2438; SPEC_SP_2440; SPEC_SP_2464; SPEC_SP_2465; SPEC_SP_2467; SPEC_SP_2468; SPEC_SP_2481\" colspan=\"5\" verticalalignment=\"0\"\u003e\u003cp\u003e\u003csup\u003e*1\u003c\/sup\u003e When using the PoE power receiving function to form a connection, use an STP cable or category 5 or higher UTP cable.\u003cbr\u003e\u003csup\u003e*2\u003c\/sup\u003e When using the switch, there is no limit on the number of units that can be connected.\u003cbr\u003e\u003csup\u003e*3\u003c\/sup\u003e \"N-bus\" is the name of KEYENCE's wiring-saving system for sensor amplifiers.\u003cbr\u003e\u003csup\u003e*4\u003c\/sup\u003e This varies depending on the connected sensor amplifiers.\u003cbr\u003e\u003csup\u003e*5\u003c\/sup\u003e This is the current that can be supplied to the main unit or to the sensor amplifier connected to the main unit.\u003cbr\u003e\u003csup\u003e*6\u003c\/sup\u003e This varies depending on the ambient usage temperature. (-20 to 45 °C \u003cspan class=\"prd-utility-color-inch\"\u003e-4 to 113°F\u003c\/span\u003e: 360 mA or less, 45 to 50 °C \u003cspan class=\"prd-utility-color-inch\"\u003e113 to 122°F\u003c\/span\u003e: 260 mA or less, 50 to 55 °C \u003cspan class=\"prd-utility-color-inch\"\u003e122 to 131°F\u003c\/span\u003e: 140 mA or less)\u003cbr\u003e\u003csup\u003e*7\u003c\/sup\u003e Power which can be supplied to the sensor amplifi er when using the PoE power receiving function\u003cbr\u003e\u003csup\u003e*8\u003c\/sup\u003e The current supplied to the connected sensor amplifiers is not included.\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prd-specsTable-overlay prd-largeScreen-hidden\"\u003e\n\u003cdiv class=\"prd-specsTable-overlayInner\" aria-hidden=\"true\" data-action=\"click-\u0026gt;scroll-to-coord#run\" data-x-coord=\"100\"\u003e\n\u003cp class=\"prd-utility-marginBottom-2\"\u003e\n\u003csvg class=\"prd-specsTable-overlayIcon\" viewbox=\"0 0 30 30\" data-action=\"click-\u0026gt;series-header#doScroll\"\u003e\n\u003cuse xlink:href=\"#icon-horizontal-scrollable\"\u003e\u003c\/use\u003e\n\u003c\/svg\u003e\n\u003c\/p\u003e\n\u003cp class=\"prd-specsTable-overlayLabel prd-utility-body-extraSmall prd-utility-marginBottom-0\"\u003eScroll\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Keyence","offers":[{"title":"Sealed Surplus","offer_id":47827918749918,"sku":"NU-EP1-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":47827918782686,"sku":"NU-EP1","price":332.1,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":47827918815454,"sku":"NU-EP1-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_keyence_stock_cc12f9ce-0e21-4ee1-8dba-8c812691f178.png?v=1768393419","url":"https:\/\/plc-direct.com\/products\/nu-ep1","provider":"PLC Direct","version":"1.0","type":"link"}