{"product_id":"nr-x100w","title":"NR-X100W Keyence","description":"\u003ch2 class=\"prd-utility-heading-3 prd-utility-marginBottom-7\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"prd-specsTable prd-utility-focusRing\" tabindex=\"0\" data-controller=\"horizontal-scroll-state scroll-to-coord\" data-action=\"resize@window-\u0026gt;horizontal-scroll-state#setOverflowing scroll-\u0026gt;horizontal-scroll-state#setScrolled\" data-horizontal-scroll-state-target=\"container\" data-horizontal-scroll-state-overflowing-class=\"is-overflowing\" data-horizontal-scroll-state-has-scrolled-class=\"is-hasScrolled\" data-scroll-to-coord-target=\"container\"\u003e\n\u003cdiv class=\"prd-utility-body-small\"\u003e\n\u003cdiv class=\"specTable-block\"\u003e\u003ctable class=\"specTable-stibo-3282397\"\u003e\u003ctbody\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"key_att_1001\" colspan=\"4\"\u003e\u003cp\u003eModel\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"key_att_1001\"\u003e\u003cp\u003eNR-X100W\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21965\" colspan=\"4\"\u003e\u003cp\u003eMain unit buffer memory capacity\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21965\"\u003e\u003cp\u003e50M data\u003csup\u003e*1\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21966\" colspan=\"4\"\u003e\u003cp\u003eExpansion memory\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21966\"\u003e\u003cp\u003eSD card (SD\/SDHC)\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21967\" rowspan=\"3\"\u003e\u003cp\u003ePC interface\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21967\" colspan=\"3\"\u003e\u003cp\u003eUSB\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21967\"\u003e\u003cp\u003eUSB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21968\" colspan=\"3\"\u003e\u003cp\u003eEthernet\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21968\"\u003e\u003cp\u003eRJ45 connector, 100Base-TX (AUTO MDI\/MDIX supported) \u003csup\u003e*3\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21969\" colspan=\"3\"\u003e\u003cp\u003eWireless LAN\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21969\"\u003e\u003cp\u003eConnection via NR-XW1 wireless LAN unit, IEEE 802.11b\/g\/n \u003csup\u003e*3\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21970\" colspan=\"4\"\u003e\u003cp\u003eNetwork function\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21970\"\u003e\u003cp\u003eFTP client function, FTP server function, SNTP client function\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21971\" colspan=\"4\"\u003e\u003cp\u003eDisplay\/operation\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21971\"\u003e\u003cp\u003eOperation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21972\" colspan=\"4\"\u003e\u003cp\u003eExpansion remote unit connection\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21972\"\u003e\u003cp\u003eDedicated remote connection connector × 2 (Remote OUT A port, B port)\u003cbr\u003eUnit expansion possible by connecting up to eight NR-XR01 remote units (connected by remote unit cable)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21973\" rowspan=\"2\"\u003e\u003cp\u003eNumber of connectable measurement units\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21973\" colspan=\"3\"\u003e\u003cp\u003eMaster data collection unit group\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21973\"\u003e\u003cp\u003eMax. 8 units\u003csup\u003e*4\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21974\" colspan=\"3\"\u003e\u003cp\u003eTotal with remote units connected\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21974\"\u003e\u003cp\u003eMax. 72 units\u003csup\u003e*5\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21975\" rowspan=\"2\"\u003e\u003cp\u003eContinuous acquisition speed\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21975\" colspan=\"3\"\u003e\u003cp\u003eMaster data collection unit group\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21975\"\u003e\u003cp\u003eMax. 100 kHz for all acquisition channels \u003csup\u003e*6\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21976\" colspan=\"3\"\u003e\u003cp\u003eTotal with remote units connected\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21976\"\u003e\u003cp\u003eMax. 500 kHz for all acquisition channels \u003csup\u003e*6\u003c\/sup\u003e\u003csup\u003e*7\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21977\" rowspan=\"2\"\u003e\u003cp\u003eInter-unit synchronization\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21977\" colspan=\"3\"\u003e\u003cp\u003eBetween measurement units in the master data collection unit group\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21977\" rowspan=\"2\"\u003e\u003cp\u003e±1 μs or less \u003csup\u003e*8\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21978\" colspan=\"3\"\u003e\u003cp\u003eBetween the master data collection unit and each remote unit \/ environment-resistant measurement unit\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21979\" colspan=\"4\"\u003e\u003cp\u003eTime axis accuracy\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21979\"\u003e\u003cp\u003e±50 ppm (23°C ±3°C \u003cspan class=\"prd-utility-color-inch\"\u003e73.4°F ±5.4°F\u003c\/span\u003e); Same time used for all remote groups, SNTP server time synchronization possible\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21980\" rowspan=\"2\"\u003e\u003cp\u003eSynchronous trigger input (SYNC input)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21980\" colspan=\"3\"\u003e\u003cp\u003ePerformance specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21980\"\u003e\u003cp\u003e• Use as external trigger input (normal mode) or synchronous acquisition input (logging mode)\u003cbr\u003e• Non-voltage (contact\/non-contact)\/voltage input, Falling edge input\u003cbr\u003e• Not insulated from system bus\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21981\" colspan=\"3\"\u003e\u003cp\u003eInput specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21981\"\u003e\u003cp\u003e• For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower\u003cbr\u003e• For voltage input: ON voltage (Lo) 1.0 V or lower, OFF voltage (Hi) 2.4 V or more, Max. input voltage: 6 V\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21982\" rowspan=\"2\"\u003e\u003cp\u003eControl input\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21982\" colspan=\"3\"\u003e\u003cp\u003eCommon specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21982\"\u003e\u003cp\u003e• Input type: Bidirectional voltage input\u003cbr\u003e• Maximum rating: 30 VDC, Minimum ON voltage: 10 VDC, Maximum OFF current: 0.2 mA\u003cbr\u003e• Insulation between input and system bus (500 VDC\/1 minute)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21983\" colspan=\"3\"\u003e\u003cp\u003eIndividual specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21983\"\u003e\u003cp\u003e• External trigger input (TRG IN): Edge input\u003cbr\u003e• Acquisition start\/stop input (START IN): Level input (only enabled in external control mode)\u003cbr\u003e• Auto-balance input (BAL): Edge input (only enabled in external control mode)\u003cbr\u003e• Program selection input 0 to 3 (PROG IN0 to 3): Level input (only enabled in external control mode)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21984\" rowspan=\"2\"\u003e\u003cp\u003eControl output\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21984\" colspan=\"3\"\u003e\u003cp\u003eCommon specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21984\"\u003e\u003cp\u003e• Output format: Photo MOS relay output\u003cbr\u003e• Maximum rating: 36 VDC, Output current: 50 mA or less (9-point total: 300 mA or less)\u003cbr\u003e• Leak current at OFF: 0.1 mA or less, Residual voltage when ON: 1 V or less\u003cbr\u003e• Insulation between output and system bus (500 VDC\/1 minute)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_21985\" colspan=\"3\"\u003e\u003cp\u003eIndividual specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21985\"\u003e\u003cp\u003e• Trigger output (TRG OUT): N.O. output, one-shot output\u003cbr\u003e• System error output (SYS ERR): N.C. output\u003cbr\u003e• Alarm output (ALARM): N.O. output\u003cbr\u003e• Judgment output 1 to 4 (OUT1 to 4): N.O. output\u003cbr\u003e• Ready output (READY): N.O. output\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21986\" colspan=\"4\"\u003e\u003cp\u003ePower supply\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21986\"\u003e\u003cp\u003e• NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) \/ Max. 72 W (when connected to DC terminal block; at 9 V: 8.0 A or less; at 24 V: 3.0 A or less; at 36 V: 2.0 A or less)\u003cbr\u003e• Battery operation possible when connected to the NR-XU15 Series battery power supply unit\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_20478\"\u003e\u003cp\u003ePower supply\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_20478\" colspan=\"3\"\u003e\u003cp\u003ePower consumption\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_20478\"\u003e\u003cp\u003e8.4 W or less (excluding connected units)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_43\" rowspan=\"2\"\u003e\u003cp\u003eEnvironmental resistance\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_43\" colspan=\"3\"\u003e\u003cp\u003eAmbient temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_43\"\u003e\u003cp\u003e0 to +40°C \u003cspan class=\"prd-utility-color-inch\"\u003e32°F to 104°F\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_44\" colspan=\"3\"\u003e\u003cp\u003eRelative humidity\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_44\"\u003e\u003cp\u003e10 to 85% RH (no condensation)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_113\" colspan=\"4\"\u003e\u003cp\u003eWeight\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_113\"\u003e\u003cp\u003eApprox. 490 g \u003cspan class=\"prd-utility-color-inch\"\u003e17.30 oz\u003c\/span\u003e (including approx. 10 g \u003cspan class=\"prd-utility-color-inch\"\u003e0.35 oz\u003c\/span\u003e for the OP-88512 (NR-X100W I\/O terminal block))\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-foot\"\u003e\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21965; SPEC_SP_21966; SPEC_SP_21968; SPEC_SP_21969; SPEC_SP_21973; SPEC_SP_21974; SPEC_SP_21975; SPEC_SP_21976; SPEC_SP_21977; SPEC_SP_21978\" colspan=\"5\" verticalalignment=\"0\"\u003e\u003cp\u003e\u003csup\u003e*1\u003c\/sup\u003e Data is not backed up when the power is turned off. The available data buffer memory per NR-X100W and NR-XR01 group is limited to 25M.\u003cbr\u003e\u003csup\u003e*2\u003c\/sup\u003e Use only products recommended by KEYENCE (CA-SD4G: 4 GB, CA-SD16G: 16 GB). Using a product not recommended by KEYENCE may result in data not being saved to the SD card during continuous acquisition.\u003cbr\u003e\u003csup\u003e*3\u003c\/sup\u003e Wired LAN and wireless LAN cannot be used at the same time. When acquiring data from a PC (using WAVE LOGGER X software), use a wired local connection only between the NR-X100W and the PC. Using an onsite local network connection or wireless LAN connection may cause acquisition to stop due to a decrease in transfer speeds caused by network load or wireless LAN communication conditions. The main unit’s automatic saving function allows data to be saved to an SD card in the main unit even if acquisition by PC stops.\u003cbr\u003e\u003csup\u003e*4\u003c\/sup\u003e Use is permitted only if the total power consumption of all connected measurement units is 20 W or less.\u003cbr\u003e\u003csup\u003e*5\u003c\/sup\u003e Use is permitted only if the total power consumption of all measurement units, remote units, and environment-resistant measurement units used in the system is 50 W or less when remote units are not connected to an AC adapter.\u003cbr\u003e\u003csup\u003e*6\u003c\/sup\u003e Acquisition from a PC may not be possible in some PC environments. [Tested conditions] OS: Windows 10 Pro (64 bit), CPU: 3.70 GHz, RAM: 16.0 GB, USB connections: One NR-X100W (no other USB devices), Ethernet connection: One-to-one connection between NR-X100W and PC; Using normal mode and saving in the standard format with a pre-installed OS and running only WAVE LOGGER X. Windows is a registered trademark or a trademark of Microsoft Corporation in the United States and\/or other countries.\u003cbr\u003e\u003csup\u003e*7\u003c\/sup\u003e Each master data collection unit group and remote unit group is limited to 100 kHz for all acquisition channels. When using 5 or more remote units, each remote unit group can have up to 50 kHz per acquisition channel.\u003cbr\u003e\u003csup\u003e*8\u003c\/sup\u003e The sampling cycle and sampling timing vary depending on the connected measurement unit. When using the NR‑CA04 in combination with other unit types, a sampling delay may occur between the NR-CA04 and the other units with some setting configurations.\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prd-specsTable-overlay prd-largeScreen-hidden\"\u003e\n\u003cdiv class=\"prd-specsTable-overlayInner\" aria-hidden=\"true\" data-action=\"click-\u0026gt;scroll-to-coord#run\" data-x-coord=\"100\"\u003e\n\u003cp class=\"prd-utility-marginBottom-2\"\u003e\n\u003csvg class=\"prd-specsTable-overlayIcon\" viewbox=\"0 0 30 30\" data-action=\"click-\u0026gt;series-header#doScroll\"\u003e\n\u003cuse xlink:href=\"#icon-horizontal-scrollable\"\u003e\u003c\/use\u003e\n\u003c\/svg\u003e\n\u003c\/p\u003e\n\u003cp class=\"prd-specsTable-overlayLabel prd-utility-body-extraSmall prd-utility-marginBottom-0\"\u003eScroll\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Keyence","offers":[{"title":"Sealed Surplus","offer_id":47827917242590,"sku":"NR-X100W-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":47827917275358,"sku":"NR-X100W","price":3265.99,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":47827917308126,"sku":"NR-X100W-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_keyence_stock_2fcb5dc8-e4c6-4ae4-ae62-8adabd2fe909.png?v=1768393416","url":"https:\/\/plc-direct.com\/products\/nr-x100w","provider":"PLC Direct","version":"1.0","type":"link"}