{"product_id":"nr-en16","title":"NR-EN16 Keyence","description":"\u003ch2 class=\"prd-utility-heading-3 prd-utility-marginBottom-7\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"prd-specsTable prd-utility-focusRing\" tabindex=\"0\" data-controller=\"horizontal-scroll-state scroll-to-coord\" data-action=\"resize@window-\u0026gt;horizontal-scroll-state#setOverflowing scroll-\u0026gt;horizontal-scroll-state#setScrolled\" data-horizontal-scroll-state-target=\"container\" data-horizontal-scroll-state-overflowing-class=\"is-overflowing\" data-horizontal-scroll-state-has-scrolled-class=\"is-hasScrolled\" data-scroll-to-coord-target=\"container\"\u003e\n\u003cdiv class=\"prd-utility-body-small\"\u003e\n\u003cdiv class=\"specTable-block\"\u003e\u003ctable class=\"specTable-stibo-3282397\"\u003e\u003ctbody\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"key_att_1001\" colspan=\"4\"\u003e\u003cp\u003eModel\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"key_att_1001\"\u003e\u003cp\u003eNR-EN16 \u003csup\u003e*1\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_22333\" colspan=\"4\"\u003e\u003cp\u003eConnection target devices\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22333\"\u003e\u003cp\u003eDL-EN1 (Connected sensor: GT2 Series, GT Series, IL Series, IG Series, IB Series, IX Series, SK Series)\u003csup\u003e*2\u003c\/sup\u003e\u003cbr\u003eNQ-EP4L (Connected sensor: FD-Q Series,FD-R Series, FD-X Series, FD-G Series, LR-T Series, FL Series, GP-M Series, FD-H Series, FD-EP Series, FD-EC Series, FI-1000, FI-T Series)\u003csup\u003e*2\u003c\/sup\u003e;\u003cbr\u003eLK-G5000 Series, CL-3000 Series, LJ-V7000 Series, LJ‑X8000 Series, LS-9000 Series;\u003cbr\u003eConnection of one of the above devices per NR-EN16 allowed\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_22003\" colspan=\"4\"\u003e\u003cp\u003eConnection target device identification\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22003\"\u003e\u003cp\u003eAutomatic identification or manual identification by specifying the IP address\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_22004\" colspan=\"4\"\u003e\u003cp\u003eCommunication protocols\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22004\"\u003e\u003cp\u003eEthernet TCP\/UDP communication, BOOTP\/DHCP client supported (compatible with the above connection target devices)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_22005\" colspan=\"4\"\u003e\u003cp\u003eInterface\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22005\"\u003e\u003cp\u003eEthernet 100Base-TX (AUTO-MDI\/MDIX-compatible), 1 port\u003csup\u003e*3\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_9203\" colspan=\"4\"\u003e\u003cp\u003eNumber of channels\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9203\"\u003e\u003cp\u003e16 ch max. (varies depending on connected devices)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_9233\" colspan=\"4\"\u003e\u003cp\u003eCollection period\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9233\"\u003e\u003cp\u003eMaximum sampling cycle: 1 ms (1 kHz) to 60 s\u003cbr\u003eWith effective rate display function for communication between connected sensors\u003csup\u003e*4\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_9288\" colspan=\"4\"\u003e\u003cp\u003eBuffer memory\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9288\"\u003e\u003cp\u003e8M data\u003csup\u003e*5\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_22006\" colspan=\"4\"\u003e\u003cp\u003eSensor power output function\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22006\"\u003e\u003cp\u003e• Output from power supply output connector (4-pole terminal block) (switchable between output ON and OFF)\u003cbr\u003e• Output voltage: 24 VDC ±10%\u003cbr\u003e• Rated current: Max. 0.6 A (switchable between 0.3 A and 0.6 A)\u003cbr\u003e• Built-in overcurrent protection function: Automatic recovery, switchable between 0.35 A (typ.) and 0.70 A (typ.) protection current\u003cbr\u003e• Class 2 power supply (CSA C22.2 No. 223 \/ UL 1310 compliant)\u003cbr\u003e• Sensor power supply not insulated from system bus\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_22282\" colspan=\"4\"\u003e\u003cp\u003ePower consumption\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22282\"\u003e\u003cp\u003e1.6 W or less\u003csup\u003e*6\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21638\" colspan=\"4\"\u003e\u003cp\u003eSurrounding air temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21638\"\u003e\u003cp\u003e0 to +40°C \u003cspan class=\"prd-utility-color-inch\"\u003e32°F to 104°F\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_21639\" colspan=\"4\"\u003e\u003cp\u003eOperating ambient humidity\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_21639\"\u003e\u003cp\u003e10 to 85% RH (no condensation)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_113\" colspan=\"4\"\u003e\u003cp\u003eWeight\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_113\"\u003e\u003cp\u003eApprox. 150 g \u003cspan class=\"prd-utility-color-inch\"\u003e5.30 oz\u003c\/span\u003e (including approx. 10 g \u003cspan class=\"prd-utility-color-inch\"\u003e0.35 oz\u003c\/span\u003e for the OP-88513 (NR-EN16 power supply terminal block))\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-foot\"\u003e\u003ctd class=\"specTable-clm-0\" attributeid=\"key_att_1001; SPEC_SP_22333; SPEC_SP_22005; SPEC_SP_9233; SPEC_SP_9288; SPEC_SP_22282\" colspan=\"5\" verticalalignment=\"0\"\u003e\u003cp\u003e\u003csup\u003e*1\u003c\/sup\u003e For NR-EN16 units, connect the Ethernet cable directly to the target device. Operation with hubs is not guaranteed.\u003cbr\u003e\u003csup\u003e*2\u003c\/sup\u003e Multiple sensors can be connected to each DL-EN1\/NQ-EP4L. The number of connectable sensors depends on the DL-EN1\/NQ-EP4L.\u003cbr\u003e\u003csup\u003e*3\u003c\/sup\u003e Max. expansion: 18 ports (with 18 units connected, using NR-X100W), 4 ports (with 4 units connected, using NR-500). Up to 4 units can be connected for each NR-X100W and NR-XR01 group when using the NR-X100W, with up to 18 units for all groups.\u003cbr\u003e\u003csup\u003e*4\u003c\/sup\u003e The effective rate may vary depending on the connected sensor and the communication conditions.\u003cbr\u003e\u003csup\u003e*5\u003c\/sup\u003e Limited by the NR-X100W buffer memory when using the NR‑X100W.\u003cbr\u003e\u003csup\u003e*6\u003c\/sup\u003e When using the power supply output function, the unit power consumption is calculated as follows regardless of the actual power output (load). Set to 0.3 A output = 10.0 W; Set to 0.6 A output = 20.0 W. The power supply output function can be set using a switch on the unit body.\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prd-specsTable-overlay prd-largeScreen-hidden\"\u003e\n\u003cdiv class=\"prd-specsTable-overlayInner\" aria-hidden=\"true\" data-action=\"click-\u0026gt;scroll-to-coord#run\" data-x-coord=\"100\"\u003e\n\u003cp class=\"prd-utility-marginBottom-2\"\u003e\n\u003csvg class=\"prd-specsTable-overlayIcon\" viewbox=\"0 0 30 30\" data-action=\"click-\u0026gt;series-header#doScroll\"\u003e\n\u003cuse xlink:href=\"#icon-horizontal-scrollable\"\u003e\u003c\/use\u003e\n\u003c\/svg\u003e\n\u003c\/p\u003e\n\u003cp class=\"prd-specsTable-overlayLabel prd-utility-body-extraSmall prd-utility-marginBottom-0\"\u003eScroll\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Keyence","offers":[{"title":"Sealed Surplus","offer_id":47827915997406,"sku":"NR-EN16-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":47827916030174,"sku":"NR-EN16","price":2307.66,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":47827916062942,"sku":"NR-EN16-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_keyence_stock_9f1a5e14-3f19-46ea-b711-45cf7174613a.png?v=1768393414","url":"https:\/\/plc-direct.com\/products\/nr-en16","provider":"PLC Direct","version":"1.0","type":"link"}