{"product_id":"metsepm2110","title":"METSEPM2110 Schneider","description":"\u003cp\u003eThis device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having 3 rows of bright red 4 digits 14.2 mm height LED display. The meter measures active energy as per accuracy class Class 1.0 complying to IEC 62053-21 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent \u0026amp; Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion for both current and volrage on per phase basis. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 44 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. it supports up to 13 different types of wiring schemes under Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. The meter also has one digital pulse output for any energy parameters congigurable to different energy scaling. Product dimensions are as follows: width 3.78 in (96 mm), depth 2.16 in (54 mm), height 3.78 in (96 mm) and product weight 10.58 oz (300 g).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003eEasyLogic PM2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003ePower meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003ePM2110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003ePower monitoring\u003cbr\u003eSub billing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower quality analysis\u003c\/td\u003e\n\u003ctd\u003etotal harmonic distortion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of measurement\u003c\/td\u003e\n\u003ctd\u003eTotal current harmonic distortion THD (I) per phase\u003cbr\u003eTotal voltage harmonic distortion THD (U) per phase\u003cbr\u003eApparent energy total\u003cbr\u003eActive and reactive energy total\u003cbr\u003eApparent power total\u003cbr\u003eActive and reactive power total\u003cbr\u003eCurrent average\u003cbr\u003eVoltage average\u003cbr\u003eFrequency average\u003cbr\u003ePower factor average\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering type\u003c\/td\u003e\n\u003ctd\u003ePeak demand power PM, QM, SM\u003cbr\u003eApparent power S, S1, S2, S3\u003cbr\u003eCurrent I, I1, I2, I3\u003cbr\u003eReactive power Q, Q1, Q2, Q3\u003cbr\u003eCalculated neutral current\u003cbr\u003eVoltage U, U21, U32, U13, V, V1, V2, V3\u003cbr\u003ePeak demand currents\u003cbr\u003eUnbalance current\u003cbr\u003eDemand power P, Q, S\u003cbr\u003eActive power P, P1, P2, P3\u003cbr\u003eActive, reactive, apparent energy (signed, four quadrant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy class\u003c\/td\u003e\n\u003ctd\u003eClass 1 active energy IEC 62053-21\u003cbr\u003eClass 1 reactive energy IEC 62053-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003eApparent power +\/- 1 %\u003cbr\u003eActive energy +\/- 1 %\u003cbr\u003eReactive energy +\/- 1 %\u003cbr\u003eActive power +\/- 1 %\u003cbr\u003eVoltage +\/- 0.5 %\u003cbr\u003ePower factor +\/- 0.01\u003cbr\u003eCurrent +\/- 0.5 %\u003cbr\u003eFrequency +\/- 0.05 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd\u003e5â¦6000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement voltage\u003c\/td\u003e\n\u003ctd\u003e35â¦480 V AC 50\/60 Hz between phases\u003cbr\u003e20â¦277 V AC 50\/60 Hz between phase and neutral\u003cbr\u003e480â¦999000 V AC 50\/60 Hz with external VT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement range\u003c\/td\u003e\n\u003ctd\u003e45â¦65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] rated supply voltage\u003c\/td\u003e\n\u003ctd\u003e44...277 V AC 45...65 Hz +\/- 10 %\u003cbr\u003e44...277 V DC +\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003cbr\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRide-through time\u003c\/td\u003e\n\u003ctd\u003e100 ms 120 V AC typical\u003cbr\u003e400 ms 230 V AC typical\u003cbr\u003e50 ms 125 V DC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Rated Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003cbr\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e6 VA 277 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption in W\u003c\/td\u003e\n\u003ctd\u003e3.3 W power lines (AC))\u003cbr\u003e2 W 277 V power lines (DC))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einput impedance\u003c\/td\u003e\n\u003ctd\u003eCurrent (impedance \u0026lt;= 0.3 mOhm)\u003cbr\u003eVoltage (impedance \u0026gt; 5 MOhm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTamperproof of settings\u003c\/td\u003e\n\u003ctd\u003eProtected by access code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e7 segments LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay colour\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMessages display capacity\u003c\/td\u003e\n\u003ctd\u003e3 fields of 4 characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay digits\u003c\/td\u003e\n\u003ctd\u003e12 - 0.6 in (14.2 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDemand intervals\u003c\/td\u003e\n\u003ctd\u003eConfigurable from 1 to 60 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInformation displayed\u003c\/td\u003e\n\u003ctd\u003eDemand current past value)\u003cbr\u003eDemand current present value)\u003cbr\u003eDemand power past value)\u003cbr\u003eDemand power present value)\u003cbr\u003eVoltage\u003cbr\u003eCurrent\u003cbr\u003eFrequency\u003cbr\u003eEnergy consumption\u003cbr\u003eHarmonic distortion\u003cbr\u003ePower factor\u003cbr\u003eActive power\u003cbr\u003eApparent power\u003cbr\u003eReactive power\u003cbr\u003eUnbalanced in %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003e3 x button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003eRed LED output signal 1...9999000 pulse\/ k_h (kWh, kVAh, kVARh)\u003cbr\u003eGreen LED module operating (RUN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e1 pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOP parameter\u003c\/td\u003e\n\u003ctd\u003e20 ms 5...40 V DC, 20 mA 1...9999000 pulse\/ k_h (kWh, kVAh, kVARh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse duration\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication port protocol\u003c\/td\u003e\n\u003ctd\u003ePOP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling rate\u003c\/td\u003e\n\u003ctd\u003e64 samples\/cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCybersecurity\u003c\/td\u003e\n\u003ctd\u003eEnable\/disable communication ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Service\u003c\/td\u003e\n\u003ctd\u003eRemote monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct certifications\u003c\/td\u003e\n\u003ctd\u003eCE conforming to IEC 61010-1\u003cbr\u003eCULus conforming to UL 61010-1\u003cbr\u003eCULus conforming to CSA C22.2 No 61010-1\u003cbr\u003eRCM\u003cbr\u003eEAC\u003cbr\u003eC-tick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Mode\u003c\/td\u003e\n\u003ctd\u003eClip-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting position\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003eFramework\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProvided equipment\u003c\/td\u003e\n\u003ctd\u003e1 x Installation guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement category\u003c\/td\u003e\n\u003ctd\u003eCategory III 480 V\u003cbr\u003eCategory II 480â¦600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Insulation Class\u003c\/td\u003e\n\u003ctd\u003eDouble insulation\u003cbr\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlame retardance\u003c\/td\u003e\n\u003ctd\u003eV-0 conforming to UL 94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eCurrent transformer screw connection bottom) 6\u003cbr\u003eVoltage inputs screw connection top) 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e3.8 in (96 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003eTotal : 3.00 in (76.09 mm)\u003cbr\u003eEmbedded : 2.43 in (61.64 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e3.8 in (96 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e10.6 oz (300 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003ePM2110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840765317342,"sku":"METSEPM2110-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":46487530897630,"sku":"METSEPM2110","price":825.0,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":46487530963166,"sku":"METSEPM2110-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_d19118e6-bc1b-4928-b466-f58a48c6726c.png?v=1753948996","url":"https:\/\/plc-direct.com\/products\/metsepm2110","provider":"PLC Direct","version":"1.0","type":"link"}