{"product_id":"lucm32bl","title":"LUCM32BL Schneider Electric","description":"\u003cp\u003eTeSys U multifunction control unit to be inserted in advanced power bases LUB320, LUB380 to form a TeSys U starter controller, for 1-phase motor applications up to 7.5kW@400V and 3-phase up to 15kW@400V. It provides full protection to motors with a rated current Ir 8-32A (Ir adjustable), overload class selectable 5-30, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). Equipped with a LCD display and a 4-button keyboard for the setting of protection and alarm parameters, and display of electrical values and events. RS485 Modbus communication RJ45 port available for remote control and integration with SoMove\/MachineExpert. To be used with a 24V DC voltage for the control of the starter (through the control terminals A1\/A2 located in the power base), it must be supplied with an external 24V DC power supply. Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS\/REACh).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLUCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eMultifunction control unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Specific Application\u003c\/td\u003e\n\u003ctd\u003eMost sophisticated control and protection requirements, with display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emain function available\u003c\/td\u003e\n\u003ctd\u003eManual or automatic reset\u003cbr\u003eMonitoring function, indication of main motor parameters\u003cbr\u003eOverload, no-load running\u003cbr\u003eProtection function alarm\u003cbr\u003eProtection against overload and short-circuit\u003cbr\u003eProtection against phase failure and phase imbalance\u003cbr\u003eEarth fault protection\u003cbr\u003eLog function\u003cbr\u003eDifferentiation of thermal overload and magnetic fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct compatibility\u003c\/td\u003e\n\u003ctd\u003ePower base LUB32\u003cbr\u003ePower base LUB38\u003cbr\u003ePower base LUB320\u003cbr\u003ePower base LUB380\u003cbr\u003eReversing contactor breaker LU2B32FU\u003cbr\u003eReversing contactor breaker LU2B38FU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork frequency\u003c\/td\u003e\n\u003ctd\u003e40...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad type\u003c\/td\u003e\n\u003ctd\u003e3-phase motor self-cooled factory setting\u003cbr\u003e3-phase motor self-cooled, force cooled settable\u003cbr\u003eSingle-phase motor self-cooled, force cooled settable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-43\u003cbr\u003eAC-41\u003cbr\u003eAC-44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e15 kW 400...440 V AC 50\/60 Hz 3 phase\u003cbr\u003e15 kW 500 V AC 50\/60 Hz 3 phase\u003cbr\u003e18.5 kW 690 V AC 50\/60 Hz 3 phase\u003cbr\u003e7.5 kW 400...440 V AC 50\/60 Hz 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003erated motor current adjustment range\u003c\/td\u003e\n\u003ctd\u003e8â¦32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal overload class\u003c\/td\u003e\n\u003ctd\u003eClass 5â¦30 50â¦60 Hz -13â¦131 Â°F (-25â¦55 Â°C) IEC 60947-6-2\u003cbr\u003eClass 5â¦30 50â¦60 Hz -13â¦131 Â°F (-25â¦55 Â°C) UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping threshold\u003c\/td\u003e\n\u003ctd\u003e14.2 x Ir +\/- 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e20...28 V DC 24 V in operation\u003cbr\u003e14.5 V DC 24 V drop-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical current consumption\u003c\/td\u003e\n\u003ctd\u003e220 mA 24 V DC I maximum while closing with LUB32\u003cbr\u003e220 mA 24 V DC I maximum while closing with LUB38\u003cbr\u003e80 mA 24 V DC I rms sealed with LUB32\u003cbr\u003e80 mA 24 V DC I rms sealed with LUB38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e1.8 W control circuit with LUB32\u003cbr\u003e1.8 W control circuit with LUB38\u003cbr\u003e0.8 W external auxiliary circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e35 ms opening with LUB32 control circuit\u003cbr\u003e35 ms opening with LUB38 control circuit\u003cbr\u003e65 ms closing with LUB32 control circuit\u003cbr\u003e65 ms closing with LUB38 control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical interface\u003c\/td\u003e\n\u003ctd\u003eRS485 multidrop RJ45 front panel Modbus RTU 19200 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMessages display capacity\u003c\/td\u003e\n\u003ctd\u003e2 lines of 12 characters LCD - English +\/- 5 % 1 % of Ir\u003cbr\u003e2 lines of 12 characters LCD - French +\/- 5 % 1 % of Ir\u003cbr\u003e2 lines of 12 characters LCD - German +\/- 5 % 1 % of Ir\u003cbr\u003e2 lines of 12 characters LCD - Italian +\/- 5 % 1 % of Ir\u003cbr\u003e2 lines of 12 characters LCD - Spanish +\/- 5 % 1 % of Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset\u003c\/td\u003e\n\u003ctd\u003eAutomatic reset setting range\u003cbr\u003eManual factory setting\u003cbr\u003eManual setting range\u003cbr\u003eRemote reset setting range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime before reset\u003c\/td\u003e\n\u003ctd\u003e1â¦1000 s manual or automatic reset settable\u003cbr\u003e120 s manual factory setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser language\u003c\/td\u003e\n\u003ctd\u003eEnglish factory setting\u003cbr\u003eEnglish, French, German, Italian, Spanish settable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInformation displayed\u003c\/td\u003e\n\u003ctd\u003eAverage current factory setting)\u003cbr\u003eAverage current settable)\u003cbr\u003eCause of last 5 faults settable)\u003cbr\u003eCurrent in phase settable)\u003cbr\u003eEarth leakage current settable)\u003cbr\u003ePhase imbalance settable)\u003cbr\u003eThermal state of motor settable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 60947-6-2\u003cbr\u003eIEC 60947-6-2\u003cbr\u003eUL 60947-4-1, with phase barrier\u003cbr\u003eCSA C22.2 No 60947-4-1, with phase barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003cbr\u003eUL\u003cbr\u003eCSA\u003cbr\u003eCCC\u003cbr\u003eEAC\u003cbr\u003eASEFA\u003cbr\u003eATEX\u003cbr\u003eMarine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e690 V IEC 60947-6-2\u003cbr\u003e600 V UL 60947-4-1\u003cbr\u003e600 V CSA C22.2 No 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV IEC 60947-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe separation of circuit\u003c\/td\u003e\n\u003ctd\u003e400 V SELV between the control and auxiliary circuits IEC 60947-1\u003cbr\u003e400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixing mode\u003c\/td\u003e\n\u003ctd\u003ePlug-in (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.8 in (45 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e2.6 in (66 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e2.4 in (60 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.386 lb(US) (0.175 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLUCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840660459742,"sku":"LUCM32BL-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":42711811391710,"sku":"LUCM32BL","price":695.49,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":42711811424478,"sku":"LUCM32BL-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LUCM32BL.jpg?v=1650414715","url":"https:\/\/plc-direct.com\/products\/lucm32bl","provider":"PLC Direct","version":"1.0","type":"link"}