{"product_id":"lu2ba0b","title":"LU2BA0B Schneider Electric","description":"\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003eTeSys U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLU2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eReversing power base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct compatibility\u003c\/td\u003e\n\u003ctd\u003eControl unit LUC.X6B\u003cbr\u003eControl unit LUC.1XB\u003cbr\u003eControl unit LUC.05B\u003cbr\u003eControl unit LUC.12B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork frequency\u003c\/td\u003e\n\u003ctd\u003e40...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e12 A at \u0026lt;= 440 V\u003cbr\u003e12 A at 500 V\u003cbr\u003e9 A at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-43\u003cbr\u003eAC-44\u003cbr\u003eAC-41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ics] rated service breaking capacity\u003c\/td\u003e\n\u003ctd\u003e50 kA at 230 V\u003cbr\u003e50 kA at 440 V\u003cbr\u003e10 kA at 500 V\u003cbr\u003e4 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003etype linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1\u003cbr\u003e type mirror contact (1 NC) conforming to IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e14.5 V AC drop-out\u003cbr\u003e20...26.5 V AC in operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical current consumption\u003c\/td\u003e\n\u003ctd\u003e2360 mA at 24 V AC I maximum while closing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e2 W for control circuit with LUCA, LUCB, LUCC, LUCD\u003cbr\u003e1.7 W for control circuit with LUCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush restraint duration\u003c\/td\u003e\n\u003ctd\u003e25 ms AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load conforming to EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load conforming to EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e150 ms with change of direction for power circuit\u003cbr\u003e75 ms without change of direction for power circuit\u003cbr\u003e35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit\u003cbr\u003e50 ms at \u0026gt;= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit\u003cbr\u003e60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit\u003cbr\u003e70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit\u003cbr\u003e75 ms closing with LUCM for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e15 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct certifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003cbr\u003eUL\u003cbr\u003eCSA\u003cbr\u003eCCC\u003cbr\u003eEAC\u003cbr\u003eASEFA\u003cbr\u003eATEX\u003cbr\u003eMarine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 60947-6-2\u003cbr\u003eIEC 60947-6-2\u003cbr\u003eUL 60947-4-1, with phase barrier\u003cbr\u003eCSA C22.2 No 60947-4-1, with phase barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e690 V conforming to IEC 60947-6-2 (pollution degree 3)\u003cbr\u003e600 V conforming to UL 60947-4-1\u003cbr\u003e600 V conforming to CSA C22.2 No 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV conforming to IEC 60947-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe separation of circuit\u003c\/td\u003e\n\u003ctd\u003e400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N\u003cbr\u003e400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixing mode\u003c\/td\u003e\n\u003ctd\u003eClipped (DIN rail)\u003cbr\u003eScrew-fixed (plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003ePower circuit: screw clamp terminals 1 cable(s) 1â¦10 mmÂ² rigid\u003cbr\u003ePower circuit: screw clamp terminals 1 cable(s) 1â¦6 mmÂ² flexible with cable end\u003cbr\u003ePower circuit: screw clamp terminals 1 cable(s) 2.5â¦10 mmÂ² flexible without cable end\u003cbr\u003ePower circuit: screw clamp terminals 2 cable(s) 1â¦6 mmÂ² flexible with cable end\u003cbr\u003ePower circuit: screw clamp terminals 2 cable(s) 1â¦6 mmÂ² rigid\u003cbr\u003ePower circuit: screw clamp terminals 2 cable(s) 1.5â¦6 mmÂ² flexible without cable end\u003cbr\u003eControl circuit: without connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003ePower circuit: 1.9â¦2.5 N.m flat screwdriver 6 mm\u003cbr\u003ePower circuit: 1.9â¦2.5 N.m Philips No 2 screwdriver 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e224 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e126 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct weight\u003c\/td\u003e\n\u003ctd\u003e1.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLU2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840654987486,"sku":"LU2BA0B-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":42694254723294,"sku":"LU2BA0B","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Used","offer_id":42694254756062,"sku":"LU2BA0B-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LU2BA0B.jpg?v=1650048170","url":"https:\/\/plc-direct.com\/products\/lu2ba0b","provider":"PLC Direct","version":"1.0","type":"link"}