{"product_id":"lu2b32b","title":"LU2B32B Schneider Electric","description":"\u003cp\u003eTeSys U standard reversing power base, 3 poles (3NO), rated 32A\/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 15kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a \"all in one\" reversing starter controller with basic or advanced protection and control functions. It is equipped with a reverser module LU2MB0B to be supplied with 24V AC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles\/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLU2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eReversing power base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct compatibility\u003c\/td\u003e\n\u003ctd\u003eControl unit LUC.X6B\u003cbr\u003eControl unit LUC.1XB\u003cbr\u003eControl unit LUC.05B\u003cbr\u003eControl unit LUC.12B\u003cbr\u003eControl unit LUC.18B\u003cbr\u003eControl unit LUC.32B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork frequency\u003c\/td\u003e\n\u003ctd\u003e40...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e32 A \u0026lt;= 440 V\u003cbr\u003e23 A 500 V\u003cbr\u003e21 A 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-43\u003cbr\u003eAC-44\u003cbr\u003eAC-41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ics] rated service breaking capacity\u003c\/td\u003e\n\u003ctd\u003e50 kA 230 V\u003cbr\u003e50 kA 440 V\u003cbr\u003e10 kA 500 V\u003cbr\u003e4 kA 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003eLinked contacts 1 NO + 1 NC) IEC 60947-4-1\u003cbr\u003eMirror contact 1 NC) IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e14.5 V AC drop-out\u003cbr\u003e20...26.5 V AC in operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical current consumption\u003c\/td\u003e\n\u003ctd\u003e2360 mA 24 V AC I maximum while closing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e3 W control circuit with LUCA, LUCB, LUCC, LUCD\u003cbr\u003e1.8 W control circuit with LUCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush restraint duration\u003c\/td\u003e\n\u003ctd\u003e25 ms AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e150 ms with change of direction power circuit\u003cbr\u003e35 ms opening control circuit\u003cbr\u003e70 ms closing control circuit\u003cbr\u003e75 ms without change of direction power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e15 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003cbr\u003eUL\u003cbr\u003eCSA\u003cbr\u003eCCC\u003cbr\u003eEAC\u003cbr\u003eASEFA\u003cbr\u003eATEX\u003cbr\u003eMarine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 60947-6-2\u003cbr\u003eIEC 60947-6-2\u003cbr\u003eUL 60947-4-1, with phase barrier\u003cbr\u003eCSA C22.2 No 60947-4-1, with phase barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e690 V IEC 60947-6-2 3)\u003cbr\u003e 600 V UL 60947-4-1\u003cbr\u003e 600 V CSA C22.2 No 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e6 kVIEC 60947-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe separation of circuit\u003c\/td\u003e\n\u003ctd\u003e400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N\u003cbr\u003e400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixing mode\u003c\/td\u003e\n\u003ctd\u003eClipped (DIN rail)\u003cbr\u003eScrew-fixed (plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit screw clamp terminals 1 0.0005â¦0.002 inÂ² (0.34â¦1.5 mmÂ²) flexible with cable end\u003cbr\u003eControl circuit screw clamp terminals 1 0.001â¦0.002 inÂ² (0.75â¦1.5 mmÂ²) flexible without cable end\u003cbr\u003eControl circuit screw clamp terminals 1 0.001â¦0.002 inÂ² (0.75â¦1.5 mmÂ²) rigid\u003cbr\u003eControl circuit screw clamp terminals 2 0.0005â¦0.002 inÂ² (0.34â¦1.5 mmÂ²) flexible with cable end\u003cbr\u003eControl circuit screw clamp terminals 2 0.001â¦0.002 inÂ² (0.75â¦1.5 mmÂ²) flexible without cable end\u003cbr\u003eControl circuit screw clamp terminals 2 0.001â¦0.002 inÂ² (0.75â¦1.5 mmÂ²) rigid\u003cbr\u003ePower circuit screw clamp terminals 1 0.002â¦0.02 inÂ² (1â¦10 mmÂ²) rigid\u003cbr\u003ePower circuit screw clamp terminals 1 0.002â¦0.009 inÂ² (1â¦6 mmÂ²) flexible with cable end\u003cbr\u003ePower circuit screw clamp terminals 1 0.004â¦0.02 inÂ² (2.5â¦10 mmÂ²) flexible without cable end\u003cbr\u003ePower circuit screw clamp terminals 2 0.002â¦0.009 inÂ² (1â¦6 mmÂ²) flexible with cable end\u003cbr\u003ePower circuit screw clamp terminals 2 0.002â¦0.009 inÂ² (1â¦6 mmÂ²) rigid\u003cbr\u003ePower circuit screw clamp terminals 2 0.002â¦0.009 inÂ² (1.5â¦6 mmÂ²) flexible without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit: 7.08â¦10.6 lbf.in (0.8â¦1.2 N.m) flat screwdriver 0.2 in (5 mm)\u003cbr\u003eControl circuit: 7.08â¦10.6 lbf.in (0.8â¦1.2 N.m) Philips no 1 screwdriver 0.2 in (5 mm)\u003cbr\u003ePower circuit: 16.8â¦22.1 lbf.in (1.9â¦2.5 N.m) flat screwdriver 0.2 in (6 mm)\u003cbr\u003ePower circuit: 16.8â¦22.1 lbf.in (1.9â¦2.5 N.m) Philips No 2 screwdriver 0.2 in (6 mm)\u003cbr\u003ePower circuit: 16.8â¦22.1 lbf.in (1.9â¦2.5 N.m) pozidriv No 2 screwdriver 0.2 in (6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.8 in (45 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e8.8 in (224 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e5.0 in (126 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e2.80 lb(US) (1.27 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLU2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840654889182,"sku":"LU2B32B-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":42694254362846,"sku":"LU2B32B","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Used","offer_id":42694254395614,"sku":"LU2B32B-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LU2B32B.jpg?v=1650048164","url":"https:\/\/plc-direct.com\/products\/lu2b32b","provider":"PLC Direct","version":"1.0","type":"link"}