{"product_id":"lp4k09008bw3","title":"LP4K09008BW3 Schneider Electric","description":"\u003cp\u003eTeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A\/690V AC-1. It provides a low consumption 24V DC coil with transient suppressor module, without built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles\/hour in AC-3 and environments until 50Â°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLP4K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eResistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epower pole contact composition\u003c\/td\u003e\n\u003ctd\u003e2 NO + 2 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit \u0026lt;= 690 V AC \u0026lt;= 400 Hz\u003cbr\u003eSignalling circuit \u0026lt;= 690 V AC \u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e20 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 690 V AC AC-1 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eDC wide range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e20 A (at 140 Â°F (60 Â°C)) for power circuit\u003cbr\u003e10 A (at 122 Â°F (50 Â°C)) for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e110 A AC for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e110 A at 220...230 V conforming to IEC 60947\u003cbr\u003e110 A at 380...400 V conforming to IEC 60947\u003cbr\u003e110 A at 415 V conforming to IEC 60947\u003cbr\u003e110 A at 440 V conforming to IEC 60947\u003cbr\u003e80 A at 500 V conforming to IEC 60947\u003cbr\u003e70 A at 660...690 V conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e90 A 122 Â°F (50 Â°C) - 1 s for power circuit\u003cbr\u003e85 A 122 Â°F (50 Â°C) - 5 s for power circuit\u003cbr\u003e80 A 122 Â°F (50 Â°C) - 10 s for power circuit\u003cbr\u003e60 A 122 Â°F (50 Â°C) - 30 s for power circuit\u003cbr\u003e45 A 122 Â°F (50 Â°C) - 1 min for power circuit\u003cbr\u003e40 A 122 Â°F (50 Â°C) - 3 min for power circuit\u003cbr\u003e20 A 122 Â°F (50 Â°C) - \u0026gt;= 15 min for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e25 A gG at \u0026lt;= 440 V for power circuit\u003cbr\u003e25 A aM for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e3 mOhm - Ith 20 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit 600 V UL 508\u003cbr\u003ePower circuit 690 V IEC 60947-4-1\u003cbr\u003ePower circuit 600 V CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in W\u003c\/td\u003e\n\u003ctd\u003e1.8 W 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in W\u003c\/td\u003e\n\u003ctd\u003e1.8 W 68 Â°F (20 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e1.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003eOperational: 0.7...1.3 Uc (at \u0026lt;122 Â°F (50 Â°C))\u003cbr\u003eDrop-out: \u0026gt;= 0.10 Uc (at \u0026lt;122 Â°F (50 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003escrew clamp terminals 1 0.002â¦0.006 inÂ² (1.5â¦4 mmÂ²)solid\u003cbr\u003e screw clamp terminals 1 0.001â¦0.006 inÂ² (0.75â¦4 mmÂ²)flexible without cable end\u003cbr\u003e screw clamp terminals 1 0.0005â¦0.004 inÂ² (0.34â¦2.5 mmÂ²)flexible with cable end\u003cbr\u003e screw clamp terminals 2 0.002â¦0.006 inÂ² (1.5â¦4 mmÂ²)solid\u003cbr\u003e screw clamp terminals 2 0.001â¦0.006 inÂ² (0.75â¦4 mmÂ²)flexible without cable end\u003cbr\u003e screw clamp terminals 2 0.0005â¦0.002 inÂ² (0.34â¦1.5 mmÂ²)flexible with cable end\u003cbr\u003ePower circuit screw clamp terminals 2 0.002 inÂ² (1.5 mmÂ²)flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting diode suppressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eRail\u003cbr\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e7.08â¦11.5 lbf.in (0.8â¦1.3 N.m) screw clamp terminals Philips No 2\u003cbr\u003e 7.08â¦11.5 lbf.in (0.8â¦1.3 N.m) screw clamp terminals flat Ã 6 mm\u003cbr\u003e 7.08â¦11.5 lbf.in (0.8â¦1.3 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e10...20 ms coil de-energisation and NO opening\u003cbr\u003e30...40 ms coil energisation and NO closing\u003cbr\u003e25...35 ms coil energisation and NC opening\u003cbr\u003e15...25 ms coil de-energisation and NC closing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e30 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e0.16 Mcycles 20 A AC-1 \u0026lt;= 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e2.3 in (58 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.8 in (45 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e2.2 in (57 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.518 lb(US) (0.235 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840650137822,"sku":"LP4K09008BW3-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":42694242894046,"sku":"LP4K09008BW3","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Used","offer_id":42694242926814,"sku":"LP4K09008BW3-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LP4K09008BW3.jpg?v=1650048001","url":"https:\/\/plc-direct.com\/products\/lp4k09008bw3","provider":"PLC Direct","version":"1.0","type":"link"}