{"product_id":"lc1f265e7","title":"LC1F265E7 Schneider","description":"\u003cp\u003eTeSys F contactor, 3 poles (3NO), 265A\/1000V AC-3, for motor applications up to 132kW@400V. It provides a low sealed consumption 48V 40-400Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles\/hour and environments until 55Â°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS\/REACh).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eTeSys F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eResistive load\u003cbr\u003eMotor control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-3\u003cbr\u003eAC-4\u003cbr\u003eAC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1000 V AC-1\u003cbr\u003e\u0026lt;= 690 V AC-3\u003cbr\u003e\u0026lt;= 690 V AC-4\u003cbr\u003e\u0026lt;= 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e48 V AC 40...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e350 A (at \u0026lt;104 Â°F (40 Â°C)) at \u0026lt;= 440 V AC AC-1\u003cbr\u003e265 A (at \u0026lt;131 Â°F (55 Â°C)) at \u0026lt;= 440 V AC AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e350 A (at 104 Â°F (40 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e2120 A conforming to IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e2200 A 104 Â°F (40 Â°C) - 10 s\u003cbr\u003e1230 A 104 Â°F (40 Â°C) - 30 s\u003cbr\u003e950 A 104 Â°F (40 Â°C) - 1 min\u003cbr\u003e620 A 104 Â°F (40 Â°C) - 3 min\u003cbr\u003e480 A 104 Â°F (40 Â°C) - 10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e315 A aM at \u0026lt;= 440 V\u003cbr\u003e400 A gG at \u0026lt;= 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e0.3 mOhm - Ith 350 A 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V IEC 60947-4-1\u003cbr\u003e 1500 V VDE 0110 group C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e37 W AC-1\u003cbr\u003e21 W AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epower pole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e132 kW at 380...400 V AC 50\/60 Hz (AC-3)\u003cbr\u003e140 kW at 415 V AC 50\/60 Hz (AC-3)\u003cbr\u003e140 kW at 440 V AC 50\/60 Hz (AC-3)\u003cbr\u003e160 kW at 500 V AC 50\/60 Hz (AC-3)\u003cbr\u003e160 kW at 660...690 V AC 50\/60 Hz (AC-3)\u003cbr\u003e147 kW at 1000 V AC 50\/60 Hz (AC-3)\u003cbr\u003e75 kW at 220...230 V AC 50\/60 Hz (AC-3)\u003cbr\u003e51 kW at 400 V AC 50\/60 Hz (AC-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003eOperational 0.85...1.1 Uc 40...400 Hz 131 Â°F (55 Â°C))\u003cbr\u003eDrop-out 0.15...0.2 Uc 40...400 Hz 131 Â°F (55 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e10 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in VA\u003c\/td\u003e\n\u003ctd\u003e650 VA, 40...400 Hz 0.9 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e10 VA, 40...400 Hz 0.9 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e2400 cyc\/h 131 Â°F (55 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e40...65 ms closing\u003cbr\u003e100...170 ms opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)flexible without cable end\u003cbr\u003eControl circuit screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)flexible without cable end\u003cbr\u003eControl circuit screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)flexible with cable end\u003cbr\u003eControl circuit screw clamp terminals 2 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²)flexible with cable end\u003cbr\u003eControl circuit screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)solid without cable end\u003cbr\u003eControl circuit screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)solid without cable end\u003cbr\u003ePower circuit bar 2 32 x 4 mm\u003cbr\u003ePower circuit lugs-ring terminals 1 0.4 inÂ² (240 mmÂ²)\u003cbr\u003ePower circuit connector 1 0.4 inÂ² (240 mmÂ²)\u003cbr\u003ePower circuit bolted connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit 10.6 lbf.in (1.2 N.m)\u003cbr\u003ePower circuit 309.8 lbf.in (35 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emotor power range\u003c\/td\u003e\n\u003ctd\u003e55â¦100 kW 200â¦240 V 3 phase\u003cbr\u003e110â¦220 kW 480â¦500 V 3 phase\u003cbr\u003e110â¦220 kW 380â¦440 V 3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor starter type\u003c\/td\u003e\n\u003ctd\u003eDirect on-line contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor coil voltage\u003c\/td\u003e\n\u003ctd\u003e48 V AC standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-4-1\u003cbr\u003eEN 60947-1\u003cbr\u003eEN 60947-4-1\u003cbr\u003eJIS C8201-4-1\u003cbr\u003eIEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eRINA\u003cbr\u003eRMRoS\u003cbr\u003eCB\u003cbr\u003eCSA\u003cbr\u003eBV\u003cbr\u003eABS\u003cbr\u003eLROS (Lloyds register of shipping)\u003cbr\u003eDNV\u003cbr\u003eUL\u003cbr\u003eUKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLC1F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eAC 40...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840628216030,"sku":"LC1F265E7-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":46487516709086,"sku":"LC1F265E7","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Used","offer_id":46487516741854,"sku":"LC1F265E7-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_0894fa7e-703c-4996-8146-8cf92ad23352.png?v=1753948938","url":"https:\/\/plc-direct.com\/products\/lc1f265e7","provider":"PLC Direct","version":"1.0","type":"link"}