{"product_id":"lc1d65m7","title":"LC1D65M7 Schneider","description":"\u003cp\u003eTeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50\/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eResistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-1\u003cbr\u003eAC-2\u003cbr\u003eAC-4\u003cbr\u003eAC-3e\u003cbr\u003eAC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit \u0026lt;= 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e65 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3 for power circuit\u003cbr\u003e65 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3e for power circuit\u003cbr\u003e80 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-1 for power circuit\u003cbr\u003e50 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e48 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e30 kW at 380...400 V AC 50 Hz\u003cbr\u003e37 kW at 500 V AC 50 Hz\u003cbr\u003e37 kW at 660...690 V AC 50 Hz\u003cbr\u003e18.5 kW at 220...230 V AC 50 Hz\u003cbr\u003e30 kW at 415 V AC 50 Hz\u003cbr\u003e37 kW at 1000 V AC 50 Hz (AC-3)\u003cbr\u003e25 kW at 415 V AC 50 Hz (AC-3)\u003cbr\u003e22 kW at 380...400 V AC 50 Hz (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Horse Power Rating\u003c\/td\u003e\n\u003ctd\u003e10 hp at 230\/240 V AC 60 Hz for 1 phase motors\u003cbr\u003e20 hp at 200\/208 V AC 60 Hz for 3 phase motors\u003cbr\u003e20 hp at 230\/240 V AC 60 Hz for 3 phase motors\u003cbr\u003e40 hp at 460\/480 V AC 60 Hz for 3 phase motors\u003cbr\u003e50 hp at 575\/600 V AC 60 Hz for 3 phase motors\u003cbr\u003e7.5 hp at 230\/240 V AC 60 Hz for 1 phase motors\u003cbr\u003e3 hp at 115 V AC 60 Hz for 1 phase motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective cover\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e80 A (at 140 Â°F (60 Â°C)) for power circuit\u003cbr\u003e10 A (at 140 Â°F (60 Â°C)) for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e140 A at 440 V AC for control circuit conforming to IEC 60947-5-1\u003cbr\u003e140 A AC for control circuit conforming to IEC 60947-5-1\u003cbr\u003e900 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e900 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e125 A gG at \u0026lt;= 690 V coordination type 1 for power circuit\u003cbr\u003e125 A gG at \u0026lt;= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1\u003cbr\u003e100 A gG at \u0026lt;= 690 V coordination type 1 for power circuit\u003cbr\u003e10 A gG for control circuit conforming to IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e6.4 W AC-1\u003cbr\u003e4.2 W AC-3e\u003cbr\u003e9.6 W AC-1\u003cbr\u003e3.7 W AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003eControl circuit 600 V UL\u003cbr\u003ePower circuit 600 V CSA\u003cbr\u003ePower circuit 600 V UL IEC 60947-1\u003cbr\u003eControl circuit 690 V IEC 60947-1\u003cbr\u003ePower circuit 690 V CSA IEC 60947-1\u003cbr\u003eControl circuit 600 V CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003cbr\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e6000000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eWithout built-in bidirectional peak limiting diode suppressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e0.8...1.1 Uc (-40â¦140 Â°F (-40â¦60 Â°C)):operational AC 50 Hz\u003cbr\u003e0.85...1.1 Uc (-40â¦140 Â°F (-40â¦60 Â°C)):operational AC 60 Hz\u003cbr\u003e1...1.1 Uc (140â¦158 Â°F (60â¦70 Â°C)):operational AC 50\/60 Hz\u003cbr\u003e0.3...0.6 Uc (-40â¦158 Â°F (-40â¦70 Â°C)):drop-out AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in VA\u003c\/td\u003e\n\u003ctd\u003e160 VA cos phi 0.75 (at 68 Â°F (20 Â°C))\u003cbr\u003e140 VA cos phi 0.75 (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e15 VA 50 Hz cos phi 0.3 (at 68 Â°F (20 Â°C))\u003cbr\u003e13 VA 60 Hz cos phi 0.3 (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e4â¦5 W at 50\/60 Hz for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e12...26 ms closing\u003cbr\u003e4...19 ms opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h at 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit: screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: rigid without cable end\u003cbr\u003eControl circuit: screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003eControl circuit: screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003eControl circuit: screw clamp terminals 1 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003eControl circuit: screw clamp terminals 2 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003ePower circuit: screw terminals 1 0.004â¦0.04 inÂ² (2.5â¦25 mmÂ²) - cable stiffness: rigid\u003cbr\u003ePower circuit: screw terminals 2 0.004â¦0.02 inÂ² (2.5â¦16 mmÂ²) - cable stiffness: rigid without cable end\u003cbr\u003ePower circuit: screw terminals 1 0.004â¦0.04 inÂ² (2.5â¦25 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003ePower circuit: screw terminals 2 0.004â¦0.02 inÂ² (2.5â¦16 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003ePower circuit: screw terminals 1 0.004â¦0.04 inÂ² (2.5â¦25 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003ePower circuit: screw terminals 2 0.004â¦0.02 inÂ² (2.5â¦10 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003eControl circuit: screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: rigid\u003cbr\u003eControl circuit: screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: rigid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2\u003cbr\u003ePower circuit 44.3 lbf.in (5 N.m) screw terminal flat Ã 6 to Ã 8 mm\u003cbr\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2\u003cbr\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ã 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003eMirror contact 1 NC IEC 60947-4-1\u003cbr\u003eMechanically linked 1 NO + 1 NC IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals description ISO nÂ°1\u003c\/td\u003e\n\u003ctd\u003e(21-22)NC\u003cbr\u003e(A1-A2)CO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-overlap time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms on energisation between NC and NO contacts\u003cbr\u003e1.5 ms on de-energisation between NC and NO contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003ePlate\u003cbr\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840612552926,"sku":"LC1D65M7-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":46487512023262,"sku":"LC1D65M7","price":867.0,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":46487512056030,"sku":"LC1D65M7-Used","price":567.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_4dd4b141-52df-4386-93d5-fe1193fe0aaa.png?v=1753948928","url":"https:\/\/plc-direct.com\/products\/lc1d65m7","provider":"PLC Direct","version":"1.0","type":"link"}