{"product_id":"lc1d65g7","title":"LC1D65G7 Schneider","description":"\u003cp\u003eTeSys Deca contactor, 3 poles (3NO), for motor control applications up to 65A\/690V AC-3 (30kW@400V). They can be used to create motor starters for almost any type of application. It provides a 120V 50\/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles\/hour and environments until 60Â°C, it procures high reliability and durability. Compact (75mm width), DIN-rail mounting or screw fixing. These contactors have UL, CSA, GOST, RINA, BV, CCC, DNV, GL, LROS certifications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eResistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-1\u003cbr\u003eAC-2\u003cbr\u003eAC-4\u003cbr\u003eAC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit \u0026lt;= 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e80 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-1 for power circuit\u003cbr\u003e65 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e120 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e30 kW at 440 V AC 50\/60 Hz (AC-3)\u003cbr\u003e11 kW at 400 V AC 50\/60 Hz (AC-4)\u003cbr\u003e30 kW at 380...400 V AC 50\/60 Hz (AC-3)\u003cbr\u003e30 kW at 415 V AC 50\/60 Hz (AC-3)\u003cbr\u003e37 kW at 1000 V AC 50\/60 Hz (AC-3)\u003cbr\u003e37 kW at 500 V AC 50\/60 Hz (AC-3)\u003cbr\u003e37 kW at 660...690 V AC 50\/60 Hz (AC-3)\u003cbr\u003e18.5 kW at 220...230 V AC 50\/60 Hz (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Horse Power Rating\u003c\/td\u003e\n\u003ctd\u003e10 hp at 230\/240 V AC 60 Hz for 1 phase motors conforming to CSA\u003cbr\u003e10 hp at 230\/240 V AC 60 Hz for 1 phase motors conforming to UL\u003cbr\u003e20 hp at 200\/208 V AC 60 Hz for 3 phase motors conforming to CSA\u003cbr\u003e20 hp at 200\/208 V AC 60 Hz for 3 phase motors conforming to UL\u003cbr\u003e20 hp at 230\/240 V AC 60 Hz for 3 phase motors conforming to CSA\u003cbr\u003e20 hp at 230\/240 V AC 60 Hz for 3 phase motors conforming to UL\u003cbr\u003e5 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA\u003cbr\u003e5 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL\u003cbr\u003e50 hp at 460\/480 V AC 60 Hz for 3 phase motors conforming to CSA\u003cbr\u003e50 hp at 460\/480 V AC 60 Hz for 3 phase motors conforming to UL\u003cbr\u003e50 hp at 575\/600 V AC 60 Hz for 3 phase motors conforming to CSA\u003cbr\u003e50 hp at 575\/600 V AC 60 Hz for 3 phase motors conforming to UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective cover\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e10 A (at 140 Â°F (60 Â°C)) for control circuit\u003cbr\u003e80 A (at 140 Â°F (60 Â°C)) for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e140 A AC for control circuit conforming to IEC 60947-5-1\u003cbr\u003e1000 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e1000 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e10 A gG for control circuit conforming to IEC 60947-5-1\u003cbr\u003e125 A gG at \u0026lt;= 690 V coordination type 1 for power circuit\u003cbr\u003e125 A gG at \u0026lt;= 690 V coordination type 2 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e1 mOhm - Ith 80 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e6.4 W AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003eControl circuit 600 V CSA\u003cbr\u003eControl circuit 600 V UL\u003cbr\u003ePower circuit 600 V CSA\u003cbr\u003ePower circuit 600 V UL\u003cbr\u003eControl circuit 690 V IEC 60947-1\u003cbr\u003ePower circuit 690 V IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e6000000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eWithout built-in bidirectional peak limiting diode suppressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e0.3...0.6 Uc (140 Â°F (60 Â°C)):drop-out AC 50\/60 Hz\u003cbr\u003e0.8...1.1 Uc (140 Â°F (60 Â°C)):operational AC 50 Hz\u003cbr\u003e0.85...1.1 Uc (140 Â°F (60 Â°C)):operational AC 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in VA\u003c\/td\u003e\n\u003ctd\u003e140 VA cos phi 0.75 (at 68 Â°F (20 Â°C))\u003cbr\u003e160 VA cos phi 0.75 (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e13 VA 50 Hz cos phi 0.3 (at 68 Â°F (20 Â°C))\u003cbr\u003e15 VA 60 Hz cos phi 0.3 (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e4â¦5 W at 50\/60 Hz for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e12...26 ms closing\u003cbr\u003e4...19 ms opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h at 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit: screw clamp terminal 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: solid without cable end\u003cbr\u003eControl circuit: screw clamp terminal 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: solid without cable end\u003cbr\u003eControl circuit: screw clamp terminal 1 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003eControl circuit: screw clamp terminal 2 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003eControl circuit: screw clamp terminal 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003eControl circuit: screw clamp terminal 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003ePower circuit: connector 1 0.004â¦0.05 inÂ² (2.5â¦35 mmÂ²) - cable stiffness: solid with cable end\u003cbr\u003ePower circuit: connector 2 0.004â¦0.05 inÂ² (2.5â¦35 mmÂ²) - cable stiffness: solid with cable end\u003cbr\u003ePower circuit: connector 1 0.004â¦0.05 inÂ² (2.5â¦35 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003ePower circuit: connector 2 0.004â¦0.04 inÂ² (2.5â¦25 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003ePower circuit: connector 1 0.004â¦0.05 inÂ² (2.5â¦35 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003ePower circuit: connector 2 0.004â¦0.05 inÂ² (2.5â¦35 mmÂ²) - cable stiffness: flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal flat Ã 6 mm\u003cbr\u003eControl circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal Philips No 2\u003cbr\u003ePower circuit 44.3 lbf.in (5 N.m) screw clamp terminal flat Ã 6 mm\u003cbr\u003ePower circuit 44.3 lbf.in (5 N.m) screw clamp terminal flat Ã 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003eMirror contact 1 NC IEC 60947-4-1\u003cbr\u003eMechanically linked 1 NO + 1 NC IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals description ISO nÂ°1\u003c\/td\u003e\n\u003ctd\u003e(A1-A2)CO\u003cbr\u003e(13-14)NO\u003cbr\u003e(21-22)NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-overlap time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms on de-energisation between NC and NO contacts\u003cbr\u003e1.5 ms on energisation between NC and NO contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eRail\u003cbr\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840612487390,"sku":"LC1D65G7-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":46487511957726,"sku":"LC1D65G7","price":732.0,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":46487511990494,"sku":"LC1D65G7-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_1a7e3d96-5b15-4dc5-8f8e-9844a961ff4d.png?v=1753948927","url":"https:\/\/plc-direct.com\/products\/lc1d65g7","provider":"PLC Direct","version":"1.0","type":"link"}