{"product_id":"lc1d65aed","title":"LC1D65AED Schneider Electric","description":"\u003cp\u003eTeSys Deca contactor, 3 poles (3NO), for motor control applications up to 65A\/690V AC-3 (30kW@400V). Rated 65A AC-3 30kW@400V, it includes a 48V DC coil and 1NO+1NC aux contacts. It provides a 48V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, control connection by screw clamp terminals. For operating rates until 3600 cycles\/hour and environments until 60Â°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Compact, DIN-rail mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Compact product, 55mm wide, for DIN-rail and panel mounting. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 48V DC coil for easy integration to all control systems. Provides 2 built-in auxiliary contacts 1NO + 1NC, NC is a certified mirror contact suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 65A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003cbr\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eResistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-4\u003cbr\u003eAC-1\u003cbr\u003eAC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit \u0026lt;= 690 V AC 25...400 Hz\u003cbr\u003ePower circuit \u0026lt;= 300 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e80 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-1 for power circuit\u003cbr\u003e65 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e11 kW at 400 V AC 50\/60 Hz (AC-4)\u003cbr\u003e18.5 kW at 220...230 V AC 50\/60 Hz (AC-3)\u003cbr\u003e30 kW at 380...400 V AC 50\/60 Hz (AC-3)\u003cbr\u003e37 kW at 500 V AC 50\/60 Hz (AC-3)\u003cbr\u003e37 kW at 660...690 V AC 50\/60 Hz (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Horse Power Rating\u003c\/td\u003e\n\u003ctd\u003e40 hp at 460\/480 V AC 50\/60 Hz for 3 phase motors\u003cbr\u003e5 hp at 115 V AC 50\/60 Hz for 1 phase motors\u003cbr\u003e10 hp at 230\/240 V AC 50\/60 Hz for 1 phase motors\u003cbr\u003e20 hp at 200\/208 V AC 50\/60 Hz for 3 phase motors\u003cbr\u003e20 hp at 230\/240 V AC 50\/60 Hz for 3 phase motors\u003cbr\u003e50 hp at 575\/600 V AC 50\/60 Hz for 3 phase motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective cover\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e10 A (at 140 Â°F (60 Â°C)) for signalling circuit\u003cbr\u003e80 A (at 140 Â°F (60 Â°C)) for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e140 A AC for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e250 A DC for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e1000 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e1000 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e640 A 104 Â°F (40 Â°C) - 10 s for power circuit\u003cbr\u003e900 A 104 Â°F (40 Â°C) - 1 s for power circuit\u003cbr\u003e110 A 104 Â°F (40 Â°C) - 10 min for power circuit\u003cbr\u003e260 A 104 Â°F (40 Â°C) - 1 min for power circuit\u003cbr\u003e100 A - 1 s for signalling circuit\u003cbr\u003e120 A - 500 ms for signalling circuit\u003cbr\u003e140 A - 100 ms for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e10 A gG for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e125 A gG at \u0026lt;= 690 V coordination type 1 for power circuit\u003cbr\u003e125 A gG at \u0026lt;= 690 V coordination type 2 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e1.5 mOhm - Ith 80 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e9.6 W AC-1\u003cbr\u003e6.3 W AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit 600 V CSA\u003cbr\u003ePower circuit 600 V UL\u003cbr\u003eSignalling circuit 690 V IEC 60947-1\u003cbr\u003eSignalling circuit 600 V CSA\u003cbr\u003eSignalling circuit 600 V UL\u003cbr\u003ePower circuit 690 V IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epollution degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e10 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e0.5 Mcycles 80 A AC-1 \u0026lt;= 440 V\u003cbr\u003e1.45 Mcycles 65 A AC-3 \u0026lt;= 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eDC standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting diode suppressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e0.1...0.3 Uc (-40â¦158 Â°F (-40â¦70 Â°C)):drop-out DC\u003cbr\u003e0.75...1.25 Uc (-40â¦140 Â°F (-40â¦60 Â°C)):operational DC\u003cbr\u003e1...1.25 Uc (140â¦158 Â°F (60â¦70 Â°C)):operational DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in W\u003c\/td\u003e\n\u003ctd\u003e19 W 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in W\u003c\/td\u003e\n\u003ctd\u003e7.4 W 68 Â°F (20 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e50 Â±15 % ms closing\u003cbr\u003e16...24 ms opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime constant\u003c\/td\u003e\n\u003ctd\u003e34 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h at 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit: screw clamp terminals 2 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003eControl circuit: screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003eControl circuit: screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003eControl circuit: screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003eControl circuit: screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: solid without cable end\u003cbr\u003eControl circuit: screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: solid without cable end\u003cbr\u003ePower circuit: screw connection 1 0.002â¦0.05 inÂ² (1â¦35 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003ePower circuit: screw connection 2 0.002â¦0.04 inÂ² (1â¦25 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003ePower circuit: screw connection 1 0.002â¦0.05 inÂ² (1â¦35 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003ePower circuit: screw connection 2 0.002â¦0.04 inÂ² (1â¦25 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003ePower circuit: screw connection 1 0.002â¦0.05 inÂ² (1â¦35 mmÂ²) - cable stiffness: solid without cable end\u003cbr\u003ePower circuit: screw connection 2 0.002â¦0.04 inÂ² (1â¦25 mmÂ²) - cable stiffness: solid without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit 15.05 lbf.in (1.7 N.m) EverLink BTR screw connectors flat Ã 6 mm\u003cbr\u003eControl circuit 15.05 lbf.in (1.7 N.m) EverLink BTR screw connectors Philips No 2\u003cbr\u003ePower circuit 70.8 lbf.in (8 N.m) EverLink BTR screw connectors 0.04â¦0.05 inÂ² (25â¦35 mmÂ²) hexagonal 0.2 in (4 mm)\u003cbr\u003ePower circuit 44.3 lbf.in (5 N.m) EverLink BTR screw connectors 0.002â¦0.04 inÂ² (1â¦25 mmÂ²) hexagonal 0.2 in (4 mm)\u003cbr\u003eControl circuit 15.05 lbf.in (1.7 N.m) EverLink BTR screw connectors pozidriv No 2\u003cbr\u003ePower circuit 22.1 lbf.in (2.5 N.m) EverLink BTR screw connectors pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003eMechanically linked 1 NO + 1 NC IEC 60947-5-1\u003cbr\u003eMirror contact 1 NC IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignalling circuit frequency\u003c\/td\u003e\n\u003ctd\u003e25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-overlap time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms on de-energisation between NC and NO contact\u003cbr\u003e1.5 ms on energisation between NC and NO contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eRail\u003cbr\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840611242206,"sku":"LC1D65AED-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":42659343794398,"sku":"LC1D65AED","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Used","offer_id":42659343827166,"sku":"LC1D65AED-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LC1D65AED.jpg?v=1649346484","url":"https:\/\/plc-direct.com\/products\/lc1d65aed","provider":"PLC Direct","version":"1.0","type":"link"}