{"product_id":"lc1d50g7","title":"LC1D50G7 Schneider","description":"\u003cp\u003eTeSys Deca contactor, 3 poles (3NO), for motor control applications up to 50A\/690V AC-3\/3e (22kW@400V). They can be used to create motor starters for almost any type of application. It provides a 120V 50\/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles\/hour and environments until 60Â°C, it procures high reliability and durability. Compact (75mm width), DIN-rail mounting or screw fixing. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 120 VAC 50\/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eResistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-3\u003cbr\u003eAC-2\u003cbr\u003eAC-4\u003cbr\u003eAC-1\u003cbr\u003eAC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit \u0026lt;= 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e80 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-1 for power circuit\u003cbr\u003e50 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3 for power circuit\u003cbr\u003e50 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3e for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e120 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e22 kW at 380...400 V AC 50\/60 Hz (AC-3)\u003cbr\u003e25 kW at 415 V AC 50\/60 Hz (AC-3)\u003cbr\u003e30 kW at 440 V AC 50\/60 Hz (AC-3)\u003cbr\u003e30 kW at 500 V AC 50\/60 Hz (AC-3)\u003cbr\u003e33 kW at 660...690 V AC 50\/60 Hz (AC-3)\u003cbr\u003e15 kW at 220...230 V AC 50\/60 Hz (AC-3)\u003cbr\u003e11 kW at 400 V AC 50\/60 Hz (AC-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Horse Power Rating\u003c\/td\u003e\n\u003ctd\u003e3 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA\u003cbr\u003e3 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL\u003cbr\u003e15 hp at 200\/208 V AC 60 Hz for 3 phase motors conforming to CSA\u003cbr\u003e15 hp at 200\/208 V AC 60 Hz for 3 phase motors conforming to UL\u003cbr\u003e15 hp at 230\/240 V AC 60 Hz for 3 phase motors conforming to CSA\u003cbr\u003e15 hp at 230\/240 V AC 60 Hz for 3 phase motors conforming to UL\u003cbr\u003e40 hp at 460\/480 V AC 60 Hz for 3 phase motors conforming to CSA\u003cbr\u003e40 hp at 460\/480 V AC 60 Hz for 3 phase motors conforming to UL\u003cbr\u003e40 hp at 575\/600 V AC 60 Hz for 3 phase motors conforming to CSA\u003cbr\u003e40 hp at 575\/600 V AC 60 Hz for 3 phase motors conforming to UL\u003cbr\u003e7.5 hp at 230\/240 V AC 60 Hz for 1 phase motors conforming to CSA\u003cbr\u003e7.5 hp at 230\/240 V AC 60 Hz for 1 phase motors conforming to UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective cover\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e10 A (at 140 Â°F (60 Â°C)) for control circuit\u003cbr\u003e80 A (at 140 Â°F (60 Â°C)) for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e140 A AC for control circuit conforming to IEC 60947-5-1\u003cbr\u003e900 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e900 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e10 A gG for control circuit conforming to IEC 60947-5-1\u003cbr\u003e100 A gG at \u0026lt;= 690 V coordination type 1 for power circuit\u003cbr\u003e100 A gG at \u0026lt;= 690 V coordination type 2 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e1.5 mOhm - Ith 80 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e3.7 W AC-3\u003cbr\u003e9.6 W AC-1\u003cbr\u003e3.7 W AC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003eControl circuit 600 V CSA\u003cbr\u003eControl circuit 600 V UL\u003cbr\u003ePower circuit 600 V CSA\u003cbr\u003ePower circuit 600 V UL\u003cbr\u003eControl circuit 690 V IEC 60947-1\u003cbr\u003ePower circuit 690 V IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e6000000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eWithout built-in bidirectional peak limiting diode suppressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e0.3...0.6 Uc (140 Â°F (60 Â°C)):drop-out AC 50\/60 Hz\u003cbr\u003e0.8...1.1 Uc (140 Â°F (60 Â°C)):operational AC 50 Hz\u003cbr\u003e0.85...1.1 Uc (140 Â°F (60 Â°C)):operational AC 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in VA\u003c\/td\u003e\n\u003ctd\u003e140 VA cos phi 0.75 (at 68 Â°F (20 Â°C))\u003cbr\u003e160 VA cos phi 0.75 (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e13 VA 50 Hz cos phi 0.3 (at 68 Â°F (20 Â°C))\u003cbr\u003e15 VA 60 Hz cos phi 0.3 (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e4â¦5 W at 50\/60 Hz for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e12...26 ms closing\u003cbr\u003e4...19 ms opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h at 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit: screw clamp terminal 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: solid without cable end\u003cbr\u003eControl circuit: screw clamp terminal 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: solid without cable end\u003cbr\u003eControl circuit: screw clamp terminal 1 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003eControl circuit: screw clamp terminal 2 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003eControl circuit: screw clamp terminal 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003eControl circuit: screw clamp terminal 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003ePower circuit: connector 1 0.004â¦0.05 inÂ² (2.5â¦35 mmÂ²) - cable stiffness: solid with cable end\u003cbr\u003ePower circuit: connector 2 0.004â¦0.05 inÂ² (2.5â¦35 mmÂ²) - cable stiffness: solid with cable end\u003cbr\u003ePower circuit: connector 1 0.004â¦0.05 inÂ² (2.5â¦35 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003ePower circuit: connector 2 0.004â¦0.04 inÂ² (2.5â¦25 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003ePower circuit: connector 1 0.004â¦0.05 inÂ² (2.5â¦35 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003ePower circuit: connector 2 0.004â¦0.05 inÂ² (2.5â¦35 mmÂ²) - cable stiffness: flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal flat Ã 6 mm\u003cbr\u003eControl circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal Philips No 2\u003cbr\u003ePower circuit 44.3 lbf.in (5 N.m) screw clamp terminal flat Ã 6 mm\u003cbr\u003ePower circuit 44.3 lbf.in (5 N.m) screw clamp terminal flat Ã 8 mm\u003cbr\u003eControl circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003eMirror contact 1 NC IEC 60947-4-1\u003cbr\u003eMechanically linked 1 NO + 1 NC IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-overlap time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms on de-energisation between NC and NO contacts\u003cbr\u003e1.5 ms on energisation between NC and NO contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003ePlate\u003cbr\u003eRail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840609505502,"sku":"LC1D50G7-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":46487510778078,"sku":"LC1D50G7","price":805.61,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":46487510810846,"sku":"LC1D50G7-Used","price":546.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_40014c6d-2dad-4a3c-80bf-2d21ba54946f.png?v=1753948925","url":"https:\/\/plc-direct.com\/products\/lc1d50g7","provider":"PLC Direct","version":"1.0","type":"link"}