{"product_id":"lc1d1156m5","title":"LC1D1156M5 Schneider","description":"\u003cp\u003e\"TeSys Deca contactor, 3 poles(3NO) for category AC-3 applications up to 115A @440V.\" \"It provides with 220V 50 Hz coil, with 1NO+1NC auxiliary contacts, power and control connections by screw clamp terminals.\" It procures high reliability and durability with 8 Mcycles mechanical durability and 0.95 Mcycles electrical durability. It provides IP20 protection on front face conforming to IEC 60529. It can cover -40Â°C to 60Â°C operation temperature and without derating under 3000m altitude. \"Designed for demanding applications with maximum operating rates up to 1200 cycles per hour under maximum 60Â°C.\" The dimension is 158mm x 120mm x 136mm (H x W x D), mounting on rail or plate. Multi standards certified(CCC,DNV,GL,CSA,GOST,BV,UL,LROS,RINA,UKCA).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of product\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eResistive load\u003cbr\u003eMotor control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-4\u003cbr\u003eAC-1\u003cbr\u003eAC-3\u003cbr\u003eAC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit: \u0026lt;= 1000 V AC 25...400 Hz\u003cbr\u003ePower circuit: \u0026lt;= 300 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e200 A (at \u0026lt;60 Â°C) at \u0026lt;= 440 V AC AC-1 for power circuit\u003cbr\u003e115 A (at \u0026lt;60 Â°C) at \u0026lt;= 440 V AC AC-3 for power circuit\u003cbr\u003e115 A (at \u0026lt;60 Â°C) at \u0026lt;= 440 V AC AC-3e for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e220 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e30 kW at 220...230 V AC 50\/60 Hz (AC-3)\u003cbr\u003e55 kW at 380...400 V AC 50\/60 Hz (AC-3)\u003cbr\u003e59 kW at 415...440 V AC 50\/60 Hz (AC-3)\u003cbr\u003e75 kW at 500 V AC 50\/60 Hz (AC-3)\u003cbr\u003e80 kW at 660...690 V AC 50\/60 Hz (AC-3)\u003cbr\u003e65 kW at 1000 V AC 50\/60 Hz (AC-3)\u003cbr\u003e18.5 kW at 400 V AC 50\/60 Hz (AC-4)\u003cbr\u003e30 kW at 220...230 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e55 kW at 380...400 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e59 kW at 415...440 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e75 kW at 500 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e80 kW at 660...690 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e65 kW at 1000 V AC 50\/60 Hz (AC-3e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power hp\u003c\/td\u003e\n\u003ctd\u003e30 hp at 200\/208 V AC 50\/60 Hz for 3 phases motors\u003cbr\u003e40 hp at 230\/240 V AC 50\/60 Hz for 3 phases motors\u003cbr\u003e75 hp at 460\/480 V AC 50\/60 Hz for 3 phases motors\u003cbr\u003e100 hp at 575\/600 V AC 50\/60 Hz for 3 phases motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective cover\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e200 A (at 60 Â°C) for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e1260 A at 440 V for power circuit conforming to IEC 60947\u003cbr\u003e140 A AC for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e250 A DC for signalling circuit conforming to IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e1100 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e250 A 40 Â°C - 10 min for power circuit\u003cbr\u003e550 A 40 Â°C - 1 min for power circuit\u003cbr\u003e950 A 40 Â°C - 10 s for power circuit\u003cbr\u003e1100 A 40 Â°C - 1 s for power circuit\u003cbr\u003e100 A - 1 s for signalling circuit\u003cbr\u003e120 A - 500 ms for signalling circuit\u003cbr\u003e140 A - 100 ms for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e250 A gG at \u0026lt;= 690 V coordination type 1 for power circuit\u003cbr\u003e200 A gG at \u0026lt;= 690 V coordination type 2 for power circuit\u003cbr\u003e10 A gG for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e0.6 mOhm - Ith 200 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e24 W AC-1\u003cbr\u003e7.9 W AC-3\u003cbr\u003e7.9 W AC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit: 600 V CSA certified\u003cbr\u003ePower circuit: 600 V UL certified\u003cbr\u003ePower circuit: 1000 V conforming to IEC 60947-4-1\u003cbr\u003eSignalling circuit: 690 V conforming to IEC 60947-1\u003cbr\u003eSignalling circuit: 600 V CSA certified\u003cbr\u003eSignalling circuit: 600 V UL certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epollution degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 684932 cycles contactor with nominal load conforming to EN\/ISO 13849-1\u003cbr\u003eB10d = 10000000 cycles contactor with mechanical load conforming to EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e8 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e0.8 Mcycles 200 A AC-1 at Ue \u0026lt;= 440 V\u003cbr\u003e0.95 Mcycles 115 A AC-3 at Ue \u0026lt;= 440 V\u003cbr\u003e0.95 Mcycles 115 A AC-3e at Ue \u0026lt;= 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eAC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eWithout built-in suppressor module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e0.3...0.6 Uc (-40â¦70 Â°C):drop-out AC 50 Hz\u003cbr\u003e0.85...1.1 Uc (-40â¦55 Â°C):operational AC 50 Hz\u003cbr\u003e1...1.1 Uc (55â¦70 Â°C):operational AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in VA\u003c\/td\u003e\n\u003ctd\u003e300 VA 50 Hz cos phi 0.8 (at 20 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e22 VA 50 Hz cos phi 0.3 (at 20 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e3â¦8 W at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e6...20 ms opening\u003cbr\u003e20...50 ms closing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e2400 cyc\/h at 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit: lugs-ring terminals - external diameter: 8 mm\u003cbr\u003ePower circuit: lugs-ring terminals - external diameter: 25 mm\u003cbr\u003ePower circuit: bars 1 - busbar cross section: 5 x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ã 6 mm M3.5\u003cbr\u003eControl circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5\u003cbr\u003ePower circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8\u003cbr\u003ePower circuit: 12 N.m - on bars hexagonal screw head 13 mm M8\u003cbr\u003eControl circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003etype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1\u003cbr\u003e type mirror contact 1 NC conforming to IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignalling circuit frequency\u003c\/td\u003e\n\u003ctd\u003e25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-overlap time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms on de-energisation between NC and NO contact\u003cbr\u003e1.5 ms on energisation between NC and NO contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003eRail\u003cbr\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840591548638,"sku":"LC1D1156M5-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":46487504748766,"sku":"LC1D1156M5","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Used","offer_id":46487504781534,"sku":"LC1D1156M5-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_cd7b8806-7e5b-47df-a463-a5624dc6c339.png?v=1753948904","url":"https:\/\/plc-direct.com\/products\/lc1d1156m5","provider":"PLC Direct","version":"1.0","type":"link"}