{"product_id":"evs9330-esv100","title":"EVS9330-ESV100 Lenze","description":"\u003cstyle\u003etable,th,td {border: 1px solid; border-collapse: collapse;}\u003c\/style\u003e\u003csection aria-label=\"Description\"\u003e\u003ch2\u003eDescription\u003c\/h2\u003e \u003cdiv\u003e\u003c\/div\u003e \u003cdiv\u003e\u003cdiv\u003e\n\u003cp\u003eLenze's EVS9330-ESV100 servo inverter is crafted for specialized tasks in IT mains environments. This piece of equipment has a maximum operating altitude capability of 4000 meters above sea level, allowing deployment in high-altitude scenarios. Weighing in at 36.5 kg, the inverter ensures stability during operation. The mains voltage supports a range from 320 to 528 volts AC with a frequency between 45 and 65 Hz. Additionally, it can utilize an alternative DC supply spanning from 460 to 740 volts. \u003c\/p\u003e\n\u003cp\u003eUnder standard conditions with a filter, the inverter can carry a maximum mains current of 78.0 A. When configured for motor operations, it delivers impressive performance with a motor power of 45.0 kW when operating at both 400 V and 480 V inputs. \u003c\/p\u003e\n\u003cp\u003eAt an 8 kHz output frequency, the components can generate an output power of 61.6 kVA at 400 V and 69.8 kVA at 480 V. Additionally, the PDC output power is rated at 5 kW and 6 kW for 400 V and 480 V, respectively. \u003c\/p\u003e\n\u003cp\u003eCurrent specifications indicate that the output current levels at 8 kHz are 89.0 A for 400 V and 84.0 A for 480 V. The maximum output current peaks at 133.5 A when operating at 400 V and 126.0 A at 480 V. Max standstill currents are recorded at 80.0 A (400 V) and 72.0 A (480 V). Power losses at the nominal input are calculated at 1100 W. Furthermore, as temperatures ascend, the unit experiences power derating of 2.5% for every degree Celsius rise between 40 °C to 50 °C, and a 5% reduction for every additional 1000 meters in altitude.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection aria-label=\"Technical specifications\"\u003e\u003cdiv\u003e\u003ch2\u003eTechnical specifications for EVS9330-ESV100\u003c\/h2\u003e\u003c\/div\u003e \u003cdiv\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eSeries 9300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eEVS9330-ESV100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController Type\u003c\/th\u003e\n\u003ctd\u003eServo Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign Variant\u003c\/th\u003e\n\u003ctd\u003eFor IT Mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Operating Altitude\u003c\/th\u003e\n\u003ctd\u003e4000 m above sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e36.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains Voltage\u003c\/th\u003e\n\u003ctd\u003e3 AC 320 ... 528 V ± 0%, 45 ... 65 Hz ± 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlternative DC Supply\u003c\/th\u003e\n\u003ctd\u003eDC 460 ... 740 V ± 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains Current (with Filter)\u003c\/th\u003e\n\u003ctd\u003e78.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Power (4-pole ASM)\u003c\/th\u003e\n\u003ctd\u003e45.0 kW (for 400 V and 480 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Power (8 kHz)\u003c\/th\u003e\n\u003ctd\u003e61.6 kVA (at 400 V), 69.8 kVA (at 480 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Power (PDC)\u003c\/th\u003e\n\u003ctd\u003e5 kW (at 400 V), 6 kW (at 480 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Current (8 kHz)\u003c\/th\u003e\n\u003ctd\u003e89.0 A (for 400 V), 84.0 A (for 480 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Output Current (8 kHz)\u003c\/th\u003e\n\u003ctd\u003e133.5 A (at 400 V), 126.0 A (at 480 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Standstill Current (8 kHz)\u003c\/th\u003e\n\u003ctd\u003e80.0 A (for 400 V), 72.0 A (for 480 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Loss (with I_N)\u003c\/th\u003e\n\u003ctd\u003e1100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Derating\u003c\/th\u003e\n\u003ctd\u003e2.5%\/K (between 40 °C and 50 °C); 5%\/1000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003c\/div\u003e\u003c\/section\u003e","brand":"Lenze","offers":[{"title":"Sealed Surplus","offer_id":47140692033758,"sku":"EVS9330-ESV100-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":47140692066526,"sku":"EVS9330-ESV100","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Used","offer_id":47140692099294,"sku":"EVS9330-ESV100-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_lenze_stock_18eae17e-3c24-44cc-8d36-3494fe533f80.png?v=1753947273","url":"https:\/\/plc-direct.com\/products\/evs9330-esv100","provider":"PLC Direct","version":"1.0","type":"link"}