{"product_id":"atv930d37n4","title":"ATV930D37N4 Schneider Electric","description":"\u003cp\u003eThis Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 37kW\/50hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 30kW\/40hp for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380V to 480V AC. This variable speed \/ frequency drive (VSD \/ VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master\/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet\/IP and Modbus TCP, allows deep integration into automation architectures. It is designed to be mounted in vertical position (+\/- 10 Â°) on a wall.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eAltivar Process ATV900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Specific Application\u003c\/td\u003e\n\u003ctd\u003eProcess for industrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eVariable speed drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariant\u003c\/td\u003e\n\u003ctd\u003eWith braking chopper\u003cbr\u003eStandard version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003eIndustrial Application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct destination\u003c\/td\u003e\n\u003ctd\u003eAsynchronous motors\u003cbr\u003eSynchronous motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Mode\u003c\/td\u003e\n\u003ctd\u003eWall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous output current\u003c\/td\u003e\n\u003ctd\u003e74.5 A 4 kHz normal duty\u003cbr\u003e61.5 A 4 kHz heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\u003cbr\u003eModbus serial\u003cbr\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption card\u003c\/td\u003e\n\u003ctd\u003eSlot A communication module Profibus DP V1\u003cbr\u003eSlot A communication module PROFINET\u003cbr\u003eSlot A communication module DeviceNet\u003cbr\u003eSlot A communication module EtherCAT\u003cbr\u003eSlot A communication module CANopen daisy chain RJ45\u003cbr\u003eSlot A communication module CANopen SUB-D 9\u003cbr\u003eSlot A communication module CANopen screw terminals\u003cbr\u003eSlot A\/slot B\/slot C digital and analog I\/O extension module\u003cbr\u003eSlot A\/slot B\/slot C output relay extension module\u003cbr\u003eSlot B 5\/12 V digital encoder interface module\u003cbr\u003eSlot B analog encoder interface module\u003cbr\u003eSlot B resolver encoder interface module\u003cbr\u003e communication module Ethernet Powerlink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] rated supply voltage\u003c\/td\u003e\n\u003ctd\u003e380...480 V - 15...10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] rated supply voltage\u003c\/td\u003e\n\u003ctd\u003e380...480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative symmetric mains voltage tolerance\u003c\/td\u003e\n\u003ctd\u003e10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative symmetric network frequency tolerance\u003c\/td\u003e\n\u003ctd\u003e5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal output current\u003c\/td\u003e\n\u003ctd\u003e74.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e37.0 kW normal duty\u003cbr\u003e30.0 kW heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC filter\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003cbr\u003eWith EMC plate option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eUL type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003eControl screw terminal 0.5...1.5 mmÂ² AWG 20...AWG 16\u003cbr\u003eDC bus screw terminal 25...50 mmÂ² AWG 4...AWG 1\u003cbr\u003eLine side screw terminal 35...50 mmÂ² AWG 3...AWG 1\u003cbr\u003eMotor screw terminal 35...50 mmÂ² AWG 3...AWG 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s Ethernet IP\/Modbus TCP\u003cbr\u003e4.8, 9.6, 19.2, 38.4 kbit\/s Modbus serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExchange mode\u003c\/td\u003e\n\u003ctd\u003eHalf duplex, full duplex, autonegotiation Ethernet IP\/Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData format\u003c\/td\u003e\n\u003ctd\u003e8 bits, configurable odd, even or no parity Modbus serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of polarization\u003c\/td\u003e\n\u003ctd\u003eNo impedance Modbus serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of addresses\u003c\/td\u003e\n\u003ctd\u003e1â¦247 Modbus serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003eExternal supply for digital inputs 24 V DC 19â¦30 V), \u0026lt;1.25 mA overload and short-circuit protection\u003cbr\u003eInternal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +\/- 5 %, \u0026lt;10 mA overload and short-circuit protection\u003cbr\u003eInternal supply for digital inputs and STO 24 V DC 21â¦27 V), \u0026lt;200 mA overload and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003eLocal diagnostic: 3 LED (mono\/dual colour)\u003cbr\u003eEmbedded communication status: 5 LED (dual colour)\u003cbr\u003eCommunication module status: 2 LED (dual colour)\u003cbr\u003ePresence of voltage: 1 LED (red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput compatibility\u003c\/td\u003e\n\u003ctd\u003eDI1...DI8 discrete input level 1 PLC IEC 61131-2\u003cbr\u003eDI7, DI8 pulse input level 1 PLC IEC 65A-68\u003cbr\u003eSTOA, STOB discrete input level 1 PLC IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic (source) DI1...DI8), \u0026lt; 5 V, \u0026gt; 11 V\u003cbr\u003eNegative logic (sink) DI1...DI8), \u0026gt; 16 V, \u0026lt; 10 V\u003cbr\u003ePositive logic (source) DI7, DI8), \u0026lt; 0.6 V, \u0026gt; 2.5 V\u003cbr\u003ePositive logic (source) STOA, STOB), \u0026lt; 5 V, \u0026gt; 11 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling duration\u003c\/td\u003e\n\u003ctd\u003e2 ms +\/- 0.5 ms DI1...DI8) - discrete input\u003cbr\u003e5 ms +\/- 1 ms DI7, DI8) - pulse input\u003cbr\u003e1 ms +\/- 1 ms AI1, AI2, AI3) - analog input\u003cbr\u003e5 ms +\/- 1 ms AQ1, AQ2) - analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 Â°C analog input\u003cbr\u003e+\/- 1 % AQ1, AQ2 for a temperature variation 60 Â°C analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity error\u003c\/td\u003e\n\u003ctd\u003eAI1, AI2, AI3 +\/- 0.15 % of maximum value analog input\u003cbr\u003eAQ1, AQ2 +\/- 0.2 % analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefresh time\u003c\/td\u003e\n\u003ctd\u003eRelay output R1, R2, R3)5 ms +\/- 0.5 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eBetween power and control terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input number\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input type\u003c\/td\u003e\n\u003ctd\u003eDI1...DI8 programmable, 24 V DC \u0026lt;= 30 V)3.5 kOhm\u003cbr\u003eDI7, DI8 programmable as pulse input 0â¦30 kHz, 24 V DC \u0026lt;= 30 V)\u003cbr\u003eSTOA, STOB safe torque off, 24 V DC \u0026lt;= 30 V)\u0026gt; 2.2 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input logic\u003c\/td\u003e\n\u003ctd\u003e16 preset speeds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output number\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output type\u003c\/td\u003e\n\u003ctd\u003eLogic output DQ+ 0â¦1 kHz \u0026lt;= 30 V DC 100 mA\u003cbr\u003eProgrammable as pulse output DQ+ 0â¦30 kHz \u0026lt;= 30 V DC 20 mA\u003cbr\u003eLogic output DQ- 0â¦1 kHz \u0026lt;= 30 V DC 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input number\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input type\u003c\/td\u003e\n\u003ctd\u003eAI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits\u003cbr\u003eAI1, AI2, AI3 software-configurable current 0...20 mA\/4...20 mA 250 Ohm 12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output number\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output type\u003c\/td\u003e\n\u003ctd\u003eSoftware-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits\u003cbr\u003eSoftware-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay output number\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay output type\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay logic R1 fault relay NO\/NC 100000 cycles\u003cbr\u003eConfigurable relay logic R2 sequence relay NO 1000000 cycles\u003cbr\u003eConfigurable relay logic R3 sequence relay NO 1000000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum switching current\u003c\/td\u003e\n\u003ctd\u003eRelay output R1 resistive, cos phi = 1 3 A 250 V AC\u003cbr\u003eRelay output R1 resistive, cos phi = 1 3 A 30 V DC\u003cbr\u003eRelay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC\u003cbr\u003eRelay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC\u003cbr\u003eRelay output R2, R3 resistive, cos phi = 1 5 A 250 V AC\u003cbr\u003eRelay output R2, R3 resistive, cos phi = 1 5 A 30 V DC\u003cbr\u003eRelay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC\u003cbr\u003eRelay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003eRelay output R1, R2, R3 5 mA 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical interface\u003c\/td\u003e\n\u003ctd\u003eEthernet\u003cbr\u003e2-wire RS 485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e2 RJ45\u003cbr\u003e1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod of access\u003c\/td\u003e\n\u003ctd\u003eSlave Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbits\u003cbr\u003e4.8 kbps\u003cbr\u003e9600 bit\/s\u003cbr\u003e19200 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission frame\u003c\/td\u003e\n\u003ctd\u003eRTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of addresses\u003c\/td\u003e\n\u003ctd\u003e1â¦247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData format\u003c\/td\u003e\n\u003ctd\u003e8 bits, configurable odd, even or no parity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of polarization\u003c\/td\u003e\n\u003ctd\u003eNo impedance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 quadrant operation possible\u003c\/td\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAsynchronous motor control profile\u003c\/td\u003e\n\u003ctd\u003eVariable torque standard\u003cbr\u003eOptimized torque mode\u003cbr\u003eConstant torque standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronous motor control profile\u003c\/td\u003e\n\u003ctd\u003ePermanent magnet motor\u003cbr\u003eSynchronous reluctance motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output frequency\u003c\/td\u003e\n\u003ctd\u003e599 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceleration and deceleration ramps\u003c\/td\u003e\n\u003ctd\u003eLinear adjustable separately from 0.01...9999 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor slip compensation\u003c\/td\u003e\n\u003ctd\u003eCan be suppressed\u003cbr\u003eAdjustable\u003cbr\u003eAutomatic whatever the load\u003cbr\u003eNot available in permanent magnet motor law\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency\u003c\/td\u003e\n\u003ctd\u003e2...16 kHz adjustable\u003cbr\u003e4...16 kHz with derating factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal switching frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking to standstill\u003c\/td\u003e\n\u003ctd\u003eBy DC injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake chopper integrated\u003c\/td\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine current\u003c\/td\u003e\n\u003ctd\u003e66.2 A 380 V normal duty)\u003cbr\u003e54.8 A 380 V heavy duty)\u003cbr\u003e57.3 A 480 V normal duty)\u003cbr\u003e48.3 A 480 V heavy duty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current per Phase\u003c\/td\u003e\n\u003ctd\u003e66.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output voltage\u003c\/td\u003e\n\u003ctd\u003e480.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent power\u003c\/td\u003e\n\u003ctd\u003e47.6 kVA 480 V normal duty)\u003cbr\u003e40.2 kVA 480 V heavy duty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum transient current\u003c\/td\u003e\n\u003ctd\u003e89.4 A 60 s normal duty)\u003cbr\u003e92.3 A 60 s heavy duty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProspective line Isc\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase load current at high overload\u003c\/td\u003e\n\u003ctd\u003e61.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase load current at low overload\u003c\/td\u003e\n\u003ctd\u003e74.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation in W\u003c\/td\u003e\n\u003ctd\u003eNatural convection 106 W 380 V 4 kHz\u003cbr\u003eForced convection 796 W 380 V 4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safely Limited Speed (SLS)\u003c\/td\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe brake management (SBC\/SBT)\u003c\/td\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe Operating Stop (SOS)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe Position (SP)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe programmable logic\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe Speed Monitor (SSM)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe Stop 1 (SS1)\u003c\/td\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith sft fct Safe Stop 2 (SS2)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe torque off (STO)\u003c\/td\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safely Limited Position (SLP)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe Direction (SDI)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd\u003eThermal protection motor\u003cbr\u003eSafe torque off motor\u003cbr\u003eMotor phase break motor\u003cbr\u003eThermal protection drive\u003cbr\u003eSafe torque off drive\u003cbr\u003eOverheating drive\u003cbr\u003eOvercurrent between output phases and earth drive\u003cbr\u003eOverload of output voltage drive\u003cbr\u003eShort-circuit protection drive\u003cbr\u003eMotor phase break drive\u003cbr\u003eOvervoltages on the DC bus drive\u003cbr\u003eLine supply overvoltage drive\u003cbr\u003eLine supply undervoltage drive\u003cbr\u003eLine supply phase loss drive\u003cbr\u003eOverspeed drive\u003cbr\u003eBreak on the control circuit drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity per Set\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e8.9 in (226 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e26.5 in (673 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e10.7 in (271 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e62.2 lb(US) (28.2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840214520030,"sku":"ATV930D37N4-Sealed","price":2294.81,"currency_code":"USD","in_stock":true},{"title":"Never Used Surplus","offer_id":42635363614942,"sku":"ATV930D37N4","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Used","offer_id":42635363647710,"sku":"ATV930D37N4-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/ATV930D37N4.jpg?v=1648846857","url":"https:\/\/plc-direct.com\/products\/atv930d37n4","provider":"PLC Direct","version":"1.0","type":"link"}