{"product_id":"atv630u75s6x","title":"ATV630U75S6X Schneider","description":"\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eAltivar Process ATV600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Specific Application\u003c\/td\u003e\n\u003ctd\u003eProcess and utilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eVariable speed drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariant\u003c\/td\u003e\n\u003ctd\u003eStandard version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eATV630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Mode\u003c\/td\u003e\n\u003ctd\u003eWall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus serial\u003cbr\u003eModbus TCP\u003cbr\u003eModbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] rated supply voltage\u003c\/td\u003e\n\u003ctd\u003e600 V - 15...10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] rated supply voltage\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative symmetric mains voltage tolerance\u003c\/td\u003e\n\u003ctd\u003e10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative symmetric network frequency tolerance\u003c\/td\u003e\n\u003ctd\u003e5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal output current\u003c\/td\u003e\n\u003ctd\u003e13.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct destination\u003c\/td\u003e\n\u003ctd\u003eAsynchronous motors\u003cbr\u003eSynchronous motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC filter\u003c\/td\u003e\n\u003ctd\u003eWithout EMC filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP20IEC 60529\u003cbr\u003eIP21IEC 61800-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eUL type 1 UL 508C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003etype of cooling\u003c\/td\u003e\n\u003ctd\u003eForced convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply frequency\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz - 5...5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e5.5 kW heavy duty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Horse Power Rating\u003c\/td\u003e\n\u003ctd\u003e7.5 hp heavy duty\u003cbr\u003e10 hp 600 V normal duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine current\u003c\/td\u003e\n\u003ctd\u003e11.9 A 480 V normal duty)\u003cbr\u003e10.5 A 380 V heavy duty)\u003cbr\u003e9.2 A 480 V heavy duty)\u003cbr\u003e9.9 A 600 V normal duty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous output current\u003c\/td\u003e\n\u003ctd\u003e12.7 A 4 kHz heavy duty\u003cbr\u003e13.5 A 4 kHz normal duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed drive output frequency\u003c\/td\u003e\n\u003ctd\u003e0.1â¦500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety function\u003c\/td\u003e\n\u003ctd\u003eSTO (safe torque off) SIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption card\u003c\/td\u003e\n\u003ctd\u003eSlot A communication module, PROFINET\u003cbr\u003eSlot A communication module, DeviceNet\u003cbr\u003eSlot A communication module, Modbus TCP\/EtherNet\/IP\u003cbr\u003eSlot A communication module, CANopen daisy chain RJ45\u003cbr\u003eSlot A communication module, CANopen SUB-D 9\u003cbr\u003eSlot A communication module, CANopen screw terminals\u003cbr\u003eSlot A\/slot B digital and analog I\/O extension module\u003cbr\u003eSlot A\/slot B output relay extension module\u003cbr\u003eSlot A communication module, Ethernet IP\/Modbus TCP\/MD-Link\u003cbr\u003e communication module, BACnet MS\/TP\u003cbr\u003e communication module, Ethernet Powerlink\u003cbr\u003eSlot A communication module, Profibus DP V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input number\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input type\u003c\/td\u003e\n\u003ctd\u003eDI7, DI8 programmable as pulse input 0â¦30 kHz, 24 V DC \u0026lt;= 30 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input logic\u003c\/td\u003e\n\u003ctd\u003e16 preset speeds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output number\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output type\u003c\/td\u003e\n\u003ctd\u003eRelay outputs R1A, R1B, R1C 250 V AC 3000 mA\u003cbr\u003eRelay outputs R1A, R1B, R1C 30 V DC 3000 mA\u003cbr\u003eRelay outputs R2A, R2C 250 V AC 5000 mA\u003cbr\u003eRelay outputs R2A, R2C 30 V DC 5000 mA\u003cbr\u003eRelay outputs R3A, R3C 250 V AC 5000 mA\u003cbr\u003eRelay outputs R3A, R3C 30 V DC 5000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input number\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input type\u003c\/td\u003e\n\u003ctd\u003eAI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits\u003cbr\u003eAI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits\u003cbr\u003eAI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output number\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output type\u003c\/td\u003e\n\u003ctd\u003eSoftware-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits\u003cbr\u003eSoftware-configurable current AQ1, AQ2 0...20 mA 10 bits\u003cbr\u003eSoftware-configurable current DQ-, DQ+ 30 V DC\u003cbr\u003eSoftware-configurable current DQ-, DQ+ 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay output number\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay output type\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay logic R2 sequence relay NO 100000 cycles\u003cbr\u003eConfigurable relay logic R3 sequence relay NO 100000 cycles\u003cbr\u003eConfigurable relay logic R1 fault relay NO\/NC 100000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum switching current\u003c\/td\u003e\n\u003ctd\u003eRelay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC\u003cbr\u003eRelay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC\u003cbr\u003eRelay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC\u003cbr\u003eRelay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003eRelay output R1, R2, R3 5 mA 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical interface\u003c\/td\u003e\n\u003ctd\u003eEthernet\u003cbr\u003e2-wire RS 485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod of access\u003c\/td\u003e\n\u003ctd\u003eSlave Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbits\u003cbr\u003e4800 bps, 9600 bps, 19200 bps, 38.4 Kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission frame\u003c\/td\u003e\n\u003ctd\u003eRTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= power supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible temporary current boost\u003c\/td\u003e\n\u003ctd\u003e1.5 x In 60 s heavy duty)\u003cbr\u003e1.1 x In 60 s normal duty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData format\u003c\/td\u003e\n\u003ctd\u003e8 bits, configurable odd, even or no parity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of polarization\u003c\/td\u003e\n\u003ctd\u003eNo impedance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency resolution\u003c\/td\u003e\n\u003ctd\u003eAnalog input 0.012\/50 Hz\u003cbr\u003eDisplay unit 0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003eMotor screw terminal 6...10 mmÂ² AWG 10...AWG 8\u003cbr\u003eLine side screw terminal 4...6 mmÂ² AWG 12...AWG10\u003cbr\u003eControl removable screw terminals 0.5...1.5 mmÂ² AWG 20...AWG 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector type\u003c\/td\u003e\n\u003ctd\u003eRJ45 on the remote graphic terminal)Modbus serial\u003cbr\u003eRJ45 on the remote graphic terminal)Ethernet\/Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExchange mode\u003c\/td\u003e\n\u003ctd\u003eHalf duplex, full duplex, autonegotiation Ethernet\/Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of addresses\u003c\/td\u003e\n\u003ctd\u003e1â¦247 Modbus serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003eInternal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +\/- 5 %, \u0026lt;10 mA overload and short-circuit protection\u003cbr\u003eInternal supply for digital inputs and STO 24 V DC 21â¦27 V), \u0026lt;200 mA overload and short-circuit protection\u003cbr\u003eExternal supply for digital inputs 24 V DC 19â¦30 V), \u0026lt;1.25 mA overload and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003e3 LEDs (dual colour) for embedded communication status\u003cbr\u003e4 LEDs (dual colour) for communication module status\u003cbr\u003e1 LED (red) for presence of voltage\u003cbr\u003e3 LEDs for local diagnostic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput compatibility\u003c\/td\u003e\n\u003ctd\u003eDI5, DI6 discrete input level 1 PLC IEC 65A-68\u003cbr\u003eSTOA, STOB discrete input level 1 PLC IEC 61131-2\u003cbr\u003eDI1...DI6 discrete input level 1 PLC IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic (source) DI1...DI8), \u0026lt; 5 V, \u0026gt; 11 V\u003cbr\u003eNegative logic (sink) DI1...DI8), \u0026gt; 16 V, \u0026lt; 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling duration\u003c\/td\u003e\n\u003ctd\u003e5 ms +\/- 1 ms DI5, DI6) - discrete input\u003cbr\u003e5 ms +\/- 0.1 ms AI1, AI2, AI3) - analog input\u003cbr\u003e10 ms +\/- 1 ms AO1) - analog output\u003cbr\u003e2 ms +\/- 0.5 ms DI1...DI4) - discrete input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 1 % AO1, AO2 for a temperature variation 60 Â°C analog output\u003cbr\u003e+\/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 Â°C analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity error\u003c\/td\u003e\n\u003ctd\u003eAO1, AO2 +\/- 0.2 % analog output\u003cbr\u003eAI1, AI2, AI3 +\/- 0.15 % of maximum value analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefresh time\u003c\/td\u003e\n\u003ctd\u003eRelay output R1, R2, R3)5 ms +\/- 0.5 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eBetween power and control terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariable speed drive application selection\u003c\/td\u003e\n\u003ctd\u003eFood and beverage processing other application\u003cbr\u003eMining mineral and metal fan\u003cbr\u003eMining mineral and metal pump\u003cbr\u003eOil and gas fan\u003cbr\u003eWater and waste water other application\u003cbr\u003eBuilding - HVAC screw compressor\u003cbr\u003eFood and beverage processing pump\u003cbr\u003eFood and beverage processing fan\u003cbr\u003eFood and beverage processing atomization\u003cbr\u003eOil and gas electro submersible pump (ESP)\u003cbr\u003eOil and gas water injection pump\u003cbr\u003eOil and gas jet fuel pump\u003cbr\u003eOil and gas compressor for refinery\u003cbr\u003eWater and waste water centrifuge pump\u003cbr\u003eWater and waste water positive displacement pump\u003cbr\u003eWater and waste water electro submersible pump (ESP)\u003cbr\u003eWater and waste water screw pump\u003cbr\u003eWater and waste water lobe compressor\u003cbr\u003eWater and waste water screw compressor\u003cbr\u003eWater and waste water compressor centrifugal\u003cbr\u003eWater and waste water fan\u003cbr\u003eWater and waste water conveyor\u003cbr\u003eWater and waste water mixer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power range AC-3\u003c\/td\u003e\n\u003ctd\u003e7â¦11 kW 480â¦500 V 3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure mounting\u003c\/td\u003e\n\u003ctd\u003eWall mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 quadrant operation possible\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAsynchronous motor control profile\u003c\/td\u003e\n\u003ctd\u003eOptimized torque mode\u003cbr\u003eConstant torque standard\u003cbr\u003eVariable torque standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronous motor control profile\u003c\/td\u003e\n\u003ctd\u003eSynchronous reluctance motor\u003cbr\u003ePermanent magnet motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output frequency\u003c\/td\u003e\n\u003ctd\u003e500 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceleration and deceleration ramps\u003c\/td\u003e\n\u003ctd\u003eLinear adjustable separately from 0.01...9999 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor slip compensation\u003c\/td\u003e\n\u003ctd\u003eCan be suppressed\u003cbr\u003eAutomatic whatever the load\u003cbr\u003eAdjustable\u003cbr\u003eAutomatic whatever the load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency\u003c\/td\u003e\n\u003ctd\u003e4...12 kHz with derating factor\u003cbr\u003e2...12 kHz adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal switching frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking to standstill\u003c\/td\u003e\n\u003ctd\u003eBy DC injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake chopper integrated\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current per Phase\u003c\/td\u003e\n\u003ctd\u003e9.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output voltage\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent power\u003c\/td\u003e\n\u003ctd\u003e7.6 kVA 480 V heavy duty)\u003cbr\u003e10.3 kVA 600 V normal duty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum transient current\u003c\/td\u003e\n\u003ctd\u003e19.1 A 60 s heavy duty)\u003cbr\u003e14.9 A 60 s normal duty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProspective line Isc\u003c\/td\u003e\n\u003ctd\u003e70 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase load current at high overload\u003c\/td\u003e\n\u003ctd\u003e9.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase load current at low overload\u003c\/td\u003e\n\u003ctd\u003e13.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation in W\u003c\/td\u003e\n\u003ctd\u003eForced convection 44 W 380 V 4 kHz\u003cbr\u003eNatural convection 105 W 600 V 4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safely Limited Speed (SLS)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe brake management (SBC\/SBT)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe Operating Stop (SOS)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe Position (SP)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe programmable logic\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe Speed Monitor (SSM)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe Stop 1 (SS1)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith sft fct Safe Stop 2 (SS2)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe torque off (STO)\u003c\/td\u003e\n\u003ctd\u003eTrue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safely Limited Position (SLP)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith safety function Safe Direction (SDI)\u003c\/td\u003e\n\u003ctd\u003eFalse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd\u003eSafe torque off motor\u003cbr\u003eMotor phase break motor\u003cbr\u003eThermal protection drive\u003cbr\u003eSafe torque off drive\u003cbr\u003eOverheating drive\u003cbr\u003eOvercurrent between output phases and earth drive\u003cbr\u003eOverload of output voltage drive\u003cbr\u003eShort-circuit protection drive\u003cbr\u003eMotor phase break drive\u003cbr\u003eOvervoltages on the DC bus drive\u003cbr\u003eLine supply overvoltage drive\u003cbr\u003eLine supply undervoltage drive\u003cbr\u003eLine supply phase loss drive\u003cbr\u003eOverspeed drive\u003cbr\u003eBreak on the control circuit drive\u003cbr\u003eThermal protection motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity per Set\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e6.7 in (171 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e16.1 in (409 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e9.2 in (233 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e12.1 lb(US) (5.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840187879646,"sku":"ATV630U75S6X-Sealed","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Never Used Surplus","offer_id":46487482564830,"sku":"ATV630U75S6X","price":2174.99,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":46487482597598,"sku":"ATV630U75S6X-Used","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_0b51f62c-f380-4078-8301-d16cc6ac895f.png?v=1753948738","url":"https:\/\/plc-direct.com\/products\/atv630u75s6x","provider":"PLC Direct","version":"1.0","type":"link"}