{"product_id":"xpsaxe5120p","title":"XPSAXE5120P Schneider","description":"\u003cp\u003eThis XPSAXE safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e\/Category 4 conforming to standard EN\/ISO 13849-1 and SILCL3 conforming to EN\/IEC 61508 and EN\/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN\/ISO 13850 and EN\/IEC 60204-1. 24V AC\/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It has removable terminals for easier and better control wires tightening, thus improving installation reliability.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003ePreventa Safety automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003ePreventa safety module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety module name\u003c\/td\u003e\n\u003ctd\u003eXPSAXE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety module application\u003c\/td\u003e\n\u003ctd\u003eFor emergency stop and switch monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety level\u003c\/td\u003e\n\u003ctd\u003eCan reach PL e\/category 4 EN\/ISO 13849-1\u003cbr\u003eCan reach SILCL 3 EN\/IEC 62061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability data\u003c\/td\u003e\n\u003ctd\u003eDC \u0026gt; 99 % EN\/ISO 13849-1\u003cbr\u003eMTTFd = 457 years EN\/ISO 13849-1\u003cbr\u003ePFHd = 3E-8 1\/h EN\/IEC 62061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eCaptive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mmÂ² flexible with cable end, with double bezel\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mmÂ² solid without cable end\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mmÂ² flexible without cable end\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mmÂ² flexible with cable end, without bezel\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 1.5 mmÂ² flexible with cable end, with bezel\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mmÂ² solid without cable end\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mmÂ² flexible without cable end\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mmÂ² flexible with cable end, without bezel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput type\u003c\/td\u003e\n\u003ctd\u003eRelay instantaneous opening, 3 NO, volt-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of additional circuits\u003c\/td\u003e\n\u003ctd\u003e1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] Rated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC - 15...10 %\u003cbr\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronisation time between inputs\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e4 VA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity\u003c\/td\u003e\n\u003ctd\u003e3600 VA inrush AC-15 B300 relay output\u003cbr\u003e360 VA holding AC-15 B300 relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity\u003c\/td\u003e\n\u003ctd\u003e1.5 A 24 V DC-13)50 ms relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput thermal current\u003c\/td\u003e\n\u003ctd\u003e6 A instantaneous and time delay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e6 A gG instantaneous outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum output current\u003c\/td\u003e\n\u003ctd\u003e10 mA relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum output voltage\u003c\/td\u003e\n\u003ctd\u003e17 V relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum response time on input open\u003c\/td\u003e\n\u003ctd\u003e80 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e300 V 2)IEC 60947-5-1\u003cbr\u003e300 V 2)DIN VDE 0110 part 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e4 kV III IEC 60947-5-1\u003cbr\u003e4 kV III DIN VDE 0110 part 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003e2 LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003e35 mm symmetrical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.505 lb(US) (0.229 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840993415390,"sku":"XPSAXE5120P-Sealed","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Never Used Surplus","offer_id":35629509083290,"sku":"XPSAXE5120P","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Used","offer_id":42379815157982,"sku":"XPSAXE5120P-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/XPSAXE5120P_c7735a45-af81-4b84-b1ca-d31311750e50.jpg?v=1640701111","url":"https:\/\/plc-direct.com\/en-se\/products\/xpsaxe5120p","provider":"PLC Direct","version":"1.0","type":"link"}