{"product_id":"xpsak311144p","title":"XPSAK311144P Schneider","description":"\u003cp\u003eThis XPSAK safety module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats\/edges. It meets the requirements of Performance Level PL e\/Category 4 conforming to standard EN\/ISO 13849-1 and SILCL3 conforming to EN\/IEC 61508 and EN\/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN\/ISO 13850 and EN\/IEC 60204-1. It can also be used for electrical monitoring of switches activated by protection devices, with optional selection of synchronisation time between signals, monitoring of 4-wire sensing mats or edges. And monitoring of type 4 light curtains conforming to EN\/IEC 61496-1 which have solid-state safety outputs with test function (light curtains XUSL). 24V AC\/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats\/edges, the 4 most common safety sensors in the industry. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003ePreventa Safety automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003ePreventa safety module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety module name\u003c\/td\u003e\n\u003ctd\u003eXPSAK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety module application\u003c\/td\u003e\n\u003ctd\u003eFor emergency stop, switch, sensing mat\/edges or safety light curtain monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction of module\u003c\/td\u003e\n\u003ctd\u003eMonitoring of a movable guard associated with 2 switches and automatic start\u003cbr\u003eMonitoring of electro-sensitive protection equipment (ESPE)\u003cbr\u003eSensing mat and edges monitoring\u003cbr\u003eEmergency stop monitoring 1-channel wiring\u003cbr\u003eEmergency stop with 2 NC contacts monitoring 2-channel wiring\u003cbr\u003eMultiple emergency stop monitoring 2-channel wiring\u003cbr\u003eProximity sensor monitoring\u003cbr\u003eMonitoring of a movable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety level\u003c\/td\u003e\n\u003ctd\u003eCan reach PL e\/category 4 ISO 13849-1\u003cbr\u003eCan reach SILCL 3 IEC 62061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability data\u003c\/td\u003e\n\u003ctd\u003eDC \u0026gt; 99 % ISO 13849-1\u003cbr\u003eMTTFd = 154.5 years ISO 13849-1\u003cbr\u003ePFHd = 7.39E-9 1\/h IEC 62061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of start\u003c\/td\u003e\n\u003ctd\u003eConfigurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mmÂ² flexible with cable end, with double bezel\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mmÂ² solid with cable end, with double bezel\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mmÂ² flexible with cable end, with double bezel\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mmÂ² solid with cable end, with double bezel\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mmÂ² flexible with cable end, with double bezel\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mmÂ² flexible with cable end, with double bezel\u003cbr\u003eCaptive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mmÂ² flexible with cable end, with double bezel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput type\u003c\/td\u003e\n\u003ctd\u003eRelay instantaneous opening, 3 NO, volt-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of additional circuits\u003c\/td\u003e\n\u003ctd\u003e1 NC + 4 solid state outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] Rated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V AC - 15...10 %\u003cbr\u003e24 V DC - 15...10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronisation time between inputs\u003c\/td\u003e\n\u003ctd\u003eUnlimited (manual start)\u003cbr\u003e2 or 4 s depending of wiring (automatic start)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e5 VA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput protection type\u003c\/td\u003e\n\u003ctd\u003eInternal, electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum line resistance\u003c\/td\u003e\n\u003ctd\u003e28 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity\u003c\/td\u003e\n\u003ctd\u003e180 VA holding AC-15 C300 relay output\u003cbr\u003e1800 VA inrush AC-15 C300 relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity\u003c\/td\u003e\n\u003ctd\u003e1.5 A 24 V DC-13)50 ms relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput thermal current\u003c\/td\u003e\n\u003ctd\u003e6 A per relay relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e4 A gG or gL relay output EN\/IEC 60947-5-1, DIN VDE 0660 part 200\u003cbr\u003e6 A fast blow relay output EN\/IEC 60947-5-1, DIN VDE 0660 part 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum output current\u003c\/td\u003e\n\u003ctd\u003e10 mA relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum output voltage\u003c\/td\u003e\n\u003ctd\u003e17 V relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum response time on input open\u003c\/td\u003e\n\u003ctd\u003e40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e300 V 2)IEC 60947-5-1\u003cbr\u003e300 V 2)DIN VDE 0110 part 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e4 kV III IEC 60947-5-1\u003cbr\u003e4 kV III DIN VDE 0110 part 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003e4 LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e30 mA 24 V AC on power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003e35 mm symmetrical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.7 lb(US) (0.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840993054942,"sku":"XPSAK311144P-Sealed","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Never Used Surplus","offer_id":35630063157402,"sku":"XPSAK311144P","price":7668.0,"currency_code":"SEK","in_stock":true},{"title":"Used","offer_id":42379814306014,"sku":"XPSAK311144P-Used","price":6149.0,"currency_code":"SEK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/XPSAK311144P_02533b4a-342a-4cb2-9f31-c43625fa8961.jpg?v=1640701100","url":"https:\/\/plc-direct.com\/en-se\/products\/xpsak311144p","provider":"PLC Direct","version":"1.0","type":"link"}