{"product_id":"stbart0200","title":"STBART0200 Schneider","description":"\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of product\u003c\/td\u003e\n\u003ctd\u003eModicon STB distributed I\/O solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eStandard analog input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input type\u003c\/td\u003e\n\u003ctd\u003eVoltage +\/- 80 mV\u003cbr\u003eTemperature probe -100...+260 Â°C Cu 10 2, 3 or 4 wires IEC\u003cbr\u003eTemperature probe -100...+450 Â°C Pt 100 2, 3 or 4 wires US\/JIS\u003cbr\u003eTemperature probe -100...+450 Â°C Pt 1000 2, 3 or 4 wires US\/JIS\u003cbr\u003eTemperature probe -200...+850 Â°C Pt 100 2, 3 or 4 wires IEC\u003cbr\u003eTemperature probe -200...+850 Â°C Pt 1000 2, 3 or 4 wires IEC\u003cbr\u003eTemperature probe -60...+180 Â°C Ni 100 2, 3 or 4 wires IEC\u003cbr\u003eTemperature probe -60...+180 Â°C Ni 1000 2, 3 or 4 wires IEC\u003cbr\u003eThermocouple +130...+1820 Â°C thermocouple B\u003cbr\u003eThermocouple -200...+760 Â°C thermocouple J\u003cbr\u003eThermocouple -270...+1000 Â°C thermocouple E\u003cbr\u003eThermocouple -270...+1370 Â°C thermocouple K\u003cbr\u003eThermocouple -270...+400 Â°C thermocouple T\u003cbr\u003eThermocouple -50...+1665 Â°C thermocouple R\u003cbr\u003eThermocouple -50...+1665 Â°C thermocouple S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input number\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input resolution\u003c\/td\u003e\n\u003ctd\u003e15 bits + sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of filter\u003c\/td\u003e\n\u003ctd\u003eSingle low pass input filter 25 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute maximum input\u003c\/td\u003e\n\u003ctd\u003e+\/- 7.5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold swapping\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot swapping fallback\u003c\/td\u003e\n\u003ctd\u003eYes for standard NIMs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFallback status\u003c\/td\u003e\n\u003ctd\u003eState 0 basic NIMs\u003cbr\u003eUser configurable standard NIMs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData format\u003c\/td\u003e\n\u003ctd\u003eEN 61131-2\u003cbr\u003eIEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e10000000 Ohm +\/- 80 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum supply current for sensors\u003c\/td\u003e\n\u003ctd\u003e100 mA per input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute accuracy error\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1 % of full scale 25 Â°C internal\u003cbr\u003e+\/- 0.15 % of full scale 25 Â°C external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation between channels and logic bus\u003c\/td\u003e\n\u003ctd\u003e1500 V for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing requirement\u003c\/td\u003e\n\u003ctd\u003e1 word for cold-junction compensation\u003cbr\u003e2 input words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct compatibility\u003c\/td\u003e\n\u003ctd\u003ePower distribution module STBPDT3100\/3105\u003cbr\u003eMounting base STBXBA1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] rated supply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003ePower distribution module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e30 mA at 5 V DC for logic bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mV voltage\u003cbr\u003e0.1 Â°C or 0.1 Â°F temperature probe\u003cbr\u003e0.1 Â°C or 0.1 Â°F thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion time\u003c\/td\u003e\n\u003ctd\u003e150 ms voltage 60 Hz\u003cbr\u003e170 ms voltage 50 Hz\u003cbr\u003e180 ms temperature probe 60 Hz 2 or 4 wires\u003cbr\u003e200 ms temperature probe 50 Hz 2 or 4 wires\u003cbr\u003e210 ms thermocouple with internal cold-junction compensation 60 Hz\u003cbr\u003e230 ms thermocouple with internal cold-junction compensation 50 Hz\u003cbr\u003e300 ms temperature probe 60 Hz 3 wires\u003cbr\u003e340 ms temperature probe 50 Hz 3 wires\u003cbr\u003e360 ms thermocouple with external cold-junction compensation 60 Hz\u003cbr\u003e400 ms thermocouple with external cold-junction compensation 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum wiring resistance\u003c\/td\u003e\n\u003ctd\u003e20 Ohm Cu 10 IEC\/US\/JIS 2 or 3 wires\u003cbr\u003e20 Ohm Ni 100 IEC\/US\/JIS 2 or 3 wires\u003cbr\u003e20 Ohm Pt 100 IEC\/US\/JIS 2 or 3 wires\u003cbr\u003e200 Ohm Ni 1000 IEC\/US\/JIS 2 or 3 wires\u003cbr\u003e200 Ohm Pt 1000 IEC\/US\/JIS 2 or 3 wires\u003cbr\u003e50 Ohm Cu 10 IEC\/US\/JIS 4 wires\u003cbr\u003e50 Ohm Ni 100 IEC\/US\/JIS 4 wires\u003cbr\u003e50 Ohm Pt 100 IEC\/US\/JIS 4 wires\u003cbr\u003e500 Ohm Ni 1000 IEC\/US\/JIS 4 wires\u003cbr\u003e500 Ohm Pt 1000 IEC\/US\/JIS 4 wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 1 Â°C Ni 100 25 Â°C external\u003cbr\u003e+\/- 1 Â°C Ni 100 25 Â°C internal\u003cbr\u003e+\/- 1 Â°C Ni 1000 25 Â°C external\u003cbr\u003e+\/- 1 Â°C Ni 1000 25 Â°C internal\u003cbr\u003e+\/- 1 Â°C Pt 100 25 Â°C internal\u003cbr\u003e+\/- 1 Â°C Pt 1000 25 Â°C internal\u003cbr\u003e+\/- 1.75 Â°C thermocouple B with external cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 1.75 Â°C thermocouple E with external cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 1.75 Â°C thermocouple J with external cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 1.75 Â°C thermocouple K with external cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 1.75 Â°C thermocouple R with external cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 1.75 Â°C thermocouple S with external cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 1.75 Â°C thermocouple T with external cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 2 Â°C Pt 100 25 Â°C external\u003cbr\u003e+\/- 2 Â°C Pt 1000 25 Â°C external\u003cbr\u003e+\/- 2.85 Â°C thermocouple B with external cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 2.85 Â°C thermocouple E with external cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 2.85 Â°C thermocouple J with external cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 2.85 Â°C thermocouple K with external cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 2.85 Â°C thermocouple R with external cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 2.85 Â°C thermocouple S with external cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 2.85 Â°C thermocouple T with external cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 3.6 Â°C thermocouple R with internal cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 4 Â°C Cu 10 25 Â°C external\u003cbr\u003e+\/- 4 Â°C Cu 10 25 Â°C internal\u003cbr\u003e+\/- 4 Â°C thermocouple K with internal cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 4.1 Â°C thermocouple S with internal cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 4.2 Â°C thermocouple R with internal cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 4.4 Â°C thermocouple T with internal cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 4.6 Â°C thermocouple B with internal cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 4.6 Â°C thermocouple E with internal cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 5 Â°C thermocouple S with internal cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 5.1 Â°C thermocouple J with internal cold-junction compensation 25 Â°C\u003cbr\u003e+\/- 5.5 Â°C thermocouple K with internal cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 6.4 Â°C thermocouple T with internal cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 6.8 Â°C thermocouple B with internal cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 6.8 Â°C thermocouple E with internal cold-junction compensation 60 Â°C\u003cbr\u003e+\/- 7 Â°C thermocouple J with internal cold-junction compensation 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LED\u003c\/td\u003e\n\u003ctd\u003e1 LED (green) module status (RDY)\u003cbr\u003e1 LED (red) module error (ERR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e13.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e128.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840807588062,"sku":"STBART0200-Sealed","price":2256.0,"currency_code":"SEK","in_stock":true},{"title":"Never Used Surplus","offer_id":46667380981982,"sku":"STBART0200","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Used","offer_id":46667381014750,"sku":"STBART0200-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_2d552360-b798-419f-a182-d84324876d91.png?v=1753949025","url":"https:\/\/plc-direct.com\/en-se\/products\/stbart0200","provider":"PLC Direct","version":"1.0","type":"link"}