{"product_id":"nr-cf512","title":"NR-CF512 Keyence","description":"\u003ch2 class=\"prd-utility-heading-3 prd-utility-marginBottom-7\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"prd-specsTable prd-utility-focusRing\" tabindex=\"0\" data-controller=\"horizontal-scroll-state scroll-to-coord\" data-action=\"resize@window-\u0026gt;horizontal-scroll-state#setOverflowing scroll-\u0026gt;horizontal-scroll-state#setScrolled\" data-horizontal-scroll-state-target=\"container\" data-horizontal-scroll-state-overflowing-class=\"is-overflowing\" data-horizontal-scroll-state-has-scrolled-class=\"is-hasScrolled\" data-scroll-to-coord-target=\"container\"\u003e\n\u003cdiv class=\"prd-utility-body-small\"\u003e\n\u003cdiv class=\"specTable-block\"\u003e\u003ctable class=\"specTable-stibo-3282397\"\u003e\u003ctbody\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"key_att_1001\" colspan=\"4\"\u003e\u003cp\u003eModel\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"key_att_1001\"\u003e\u003cp\u003eNR-CF512\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_9227\" rowspan=\"3\"\u003e\u003cp\u003eProtocol\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_9227\" colspan=\"3\"\u003e\u003cp\u003eSupported protocol\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9227\"\u003e\u003cp\u003eCAN: ISO 11898\u003cbr\u003eCAN FD: ISO 11898\u003cbr\u003e\u003csup\u003e*1\u003c\/sup\u003e\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_9228\" colspan=\"3\"\u003e\u003cp\u003eSupported physical layers\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9228\"\u003e\u003cp\u003eISO 11898 (High Speed)\u003csup\u003e*3\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_9229\" colspan=\"3\"\u003e\u003cp\u003eCommunication speed\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9229\"\u003e\u003cp\u003eCAN: 50 kbps to 1 Mbps\u003cbr\u003eCAN FD:\u003cbr\u003e(Arbitration) 50 kbps to 1 Mbps,\u003cbr\u003e(Data) 500 kbps to 5 Mbps\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_9230\" rowspan=\"2\"\u003e\u003cp\u003ePort\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_9230\" colspan=\"3\"\u003e\u003cp\u003eNumber of ports\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9230\"\u003e\u003cp\u003e1 port\u003csup\u003e*4\u003c\/sup\u003e, \u003csup\u003e*5\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_9231\" colspan=\"3\"\u003e\u003cp\u003eDesign\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9231\"\u003e\u003cp\u003eD-sub 9-pin male\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_9232\" colspan=\"4\"\u003e\u003cp\u003eMaximum number of messages\/maximum number of signals\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9232\"\u003e\u003cp\u003e128 messages\/port \u003csup\u003e*6\u003c\/sup\u003e\u003cbr\u003e512 signals (ch)\/port\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_9233\" colspan=\"4\"\u003e\u003cp\u003eCollection period\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9233\"\u003e\u003cp\u003eCAN: Max. sampling cycle of 200 µs\u003cbr\u003eCAN FD: Max. sampling cycle of 1 ms\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_9235\" colspan=\"4\"\u003e\u003cp\u003eBuilt-in termination resistor\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9235\"\u003e\u003cp\u003e120 Ω x1 (selectable using software)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_9236\" colspan=\"4\"\u003e\u003cp\u003eManual transmission\/reception\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9236\"\u003e\u003cp\u003eSpecify message ID and data to transmit and receive\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_9253\"\u003e\u003cp\u003eWithstand voltage\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_9253\" colspan=\"3\"\u003e\u003cp\u003eMeasurement input terminal - System bus\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9253\"\u003e\u003cp\u003e500 V AC (50 Hz\/60 Hz) for 1 minute\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_9332\"\u003e\u003cp\u003eRating\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_9332\" colspan=\"3\"\u003e\u003cp\u003ePower consumption\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_9332\"\u003e\u003cp\u003e1.6 W max.\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_43\" rowspan=\"2\"\u003e\u003cp\u003eEnvironmental resistance\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_43\" colspan=\"3\"\u003e\u003cp\u003eAmbient temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_43\"\u003e\u003cp\u003e0°C to +40°C \u003cspan class=\"prd-utility-color-inch\"\u003e32°F to 104°F\u003c\/span\u003e (no freezing)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_44\" colspan=\"3\"\u003e\u003cp\u003eRelative humidity\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_44\"\u003e\u003cp\u003e10% to 85% RH (no condensation)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_113\" colspan=\"4\"\u003e\u003cp\u003eWeight\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_113\"\u003e\u003cp\u003eApprox. 140 g \u003cspan class=\"prd-utility-color-inch\"\u003e4.94 oz\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-foot\"\u003e\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_9227; SPEC_SP_9228; SPEC_SP_9230; SPEC_SP_9232\" colspan=\"5\" verticalalignment=\"0\"\u003e\u003cp\u003e\u003csup\u003e*1\u003c\/sup\u003e Switching between CAN and CAN FD is possible in the settings. Simultaneous use within one port is not possible.\u003cbr\u003e\u003csup\u003e*2\u003c\/sup\u003e Only messages that are not multiplexed to multiple signals are supported.\u003cbr\u003e\u003csup\u003e*3\u003c\/sup\u003e Excludes the Wake-up Pattern function.\u003cbr\u003e\u003csup\u003e*4\u003c\/sup\u003e When using CAN protocol, expansion up to 8 ports (8 connected units) is possible with the NR-X, and up to 4 ports (4 connected units) with the NR-500. Each NR-X100W and NR-XR01 group can be connected to a maximum of 4 units, for a total of 8 units.\u003cbr\u003e\u003csup\u003e*5\u003c\/sup\u003e When using CAN FD protocol, expansion up to 4 ports is possible with the NR-X, and up to 2 ports with the NR-500. Each NR-X100W and NR-XR01 group can be connected to a maximum of 2 units, for a total of 4 units.\u003cbr\u003e\u003csup\u003e*6\u003c\/sup\u003e If format of the message ID is extended, up to 64 messages are supported.\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prd-specsTable-overlay prd-largeScreen-hidden\"\u003e\n\u003cdiv class=\"prd-specsTable-overlayInner\" aria-hidden=\"true\" data-action=\"click-\u0026gt;scroll-to-coord#run\" data-x-coord=\"100\"\u003e\n\u003cp class=\"prd-utility-marginBottom-2\"\u003e\n\u003csvg class=\"prd-specsTable-overlayIcon\" viewbox=\"0 0 30 30\" data-action=\"click-\u0026gt;series-header#doScroll\"\u003e\n\u003cuse xlink:href=\"#icon-horizontal-scrollable\"\u003e\u003c\/use\u003e\n\u003c\/svg\u003e\n\u003c\/p\u003e\n\u003cp class=\"prd-specsTable-overlayLabel prd-utility-body-extraSmall prd-utility-marginBottom-0\"\u003eScroll\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Keyence","offers":[{"title":"Sealed Surplus","offer_id":47827915112670,"sku":"NR-CF512-Sealed","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Never Used Surplus","offer_id":47827915145438,"sku":"NR-CF512","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Used","offer_id":47827915178206,"sku":"NR-CF512-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_keyence_stock_ae4ea866-b411-4e28-a218-fd1a2a456715.png?v=1768393413","url":"https:\/\/plc-direct.com\/en-se\/products\/nr-cf512","provider":"PLC Direct","version":"1.0","type":"link"}