{"product_id":"lv430406","title":"LV430406 Schneider Electric","description":"\u003cp\u003eThis is a 3 poles basic frame for Compact NSX160N. Compact NSX is designed to optimize space and breaking capacity for all standard and specific applications. This basic frame comes without trip unit, and is compatible with any type of trip unit which has to be ordered separately The breaking capacity Icu is 50kA at 415VAC 50\/60Hz. The operational voltage is 690VAC 50\/60Hz (limited to 440VAC 50\/60Hz if there is an earth-leakage protection). It can be equipped with a variety of optional functions and accessories. The dimensions are 105mm x 161mm x 86mm. It ensures compliance with international standards (IEC 60947), CCC, EAC and marine specifications. Compact NSX160N is part of Schneider Electric EcoStruxure Power architecture.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eComPact NSX100...250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eNSX160N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eBasic frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit breaker name\u003c\/td\u003e\n\u003ctd\u003eCompact NSX160N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Rated Current\u003c\/td\u003e\n\u003ctd\u003e160 A 104 Â°F (40 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] rated ultimate short-circuit breaking capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA 600 V AC 50\/60 Hz UL 508\u003cbr\u003e85 kA 240 V AC 50\/60 Hz UL 508\u003cbr\u003e10 kA Icu 660\/690 V AC 50\/60 Hz IEC 60947-2\u003cbr\u003e35 kA Icu 525 V AC 50\/60 Hz IEC 60947-2\u003cbr\u003e50 kA 480 V AC 50\/60 Hz UL 508\u003cbr\u003e36 kA Icu 500 V AC 50\/60 Hz IEC 60947-2\u003cbr\u003e50 kA Icu 380\/415 V AC 50\/60 Hz IEC 60947-2\u003cbr\u003e50 kA Icu 440 V AC 50\/60 Hz IEC 60947-2\u003cbr\u003e90 kA Icu 220\/240 V AC 50\/60 Hz IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance level\u003c\/td\u003e\n\u003ctd\u003eN 50 kA 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Mode\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V AC 50\/60 Hz IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kVIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ics] rated service short-circuit breaking capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA 660\/690 V AC 50\/60 Hz IEC 60947-2\u003cbr\u003e35 kA 525 V AC 50\/60 Hz IEC 60947-2\u003cbr\u003e36 kA 500 V AC 50\/60 Hz IEC 60947-2\u003cbr\u003e50 kA 380\/415 V AC 50\/60 Hz IEC 60947-2\u003cbr\u003e50 kA 440 V AC 50\/60 Hz IEC 60947-2\u003cbr\u003e90 kA 220\/240 V AC 50\/60 Hz IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e40000 cycles IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e40000 cycles 440 V AC 50\/60 Hz In\/2 IEC 60947-2\u003cbr\u003e 15000 cycles 690 V AC 50\/60 Hz In\/2 IEC 60947-2\u003cbr\u003e 20000 cycles 440 V AC 50\/60 Hz In IEC 60947-2\u003cbr\u003e 7500 cycles 690 V AC 50\/60 Hz In IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eBackplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpside connection\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDownside connection\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection pitch\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eWithout protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth (W)\u003c\/td\u003e\n\u003ctd\u003e4.1 in (105 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight (H)\u003c\/td\u003e\n\u003ctd\u003e6.3 in (161 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth (D)\u003c\/td\u003e\n\u003ctd\u003e3.4 in (86 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840687001822,"sku":"LV430406-Sealed","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Never Used Surplus","offer_id":42717795582174,"sku":"LV430406","price":5686.0,"currency_code":"SEK","in_stock":true},{"title":"Used","offer_id":42717795614942,"sku":"LV430406-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LV430406.jpg?v=1650513507","url":"https:\/\/plc-direct.com\/en-se\/products\/lv430406","provider":"PLC Direct","version":"1.0","type":"link"}