{"product_id":"ltmr08efm","title":"LTMR08EFM Schneider Electric","description":"\u003cp\u003eTeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. Ethernet\/IP and Modbus\/TCP protocol is used by this controller. Ethernet TCP\/IP communication is used. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 0.4 to 8 amperes. 120 to 240 VAC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003eTeSys T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLTMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eMotor controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003eEquipment monitoring and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd\u003e0.4â¦8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] rated supply voltage\u003c\/td\u003e\n\u003ctd\u003e100...240 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e8...62.8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage limits\u003c\/td\u003e\n\u003ctd\u003e93.5â¦264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus type\u003c\/td\u003e\n\u003ctd\u003eEthernet IEEE 802.3 0...159 10...100 Mbit\/s, RJ45 2 shielded twisted pairs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e690 V EN\/IEC 60947-1\u003cbr\u003e690 V CSA C22.2 No 14\u003cbr\u003e690 V UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e4 kV supply, inputs and outputs EN\/IEC 60947-4-1\u003cbr\u003e6 kV current or voltage measurement circuit EN\/IEC 60947-4-1\u003cbr\u003e0.8 kV communication circuit EN\/IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit withstand\u003c\/td\u003e\n\u003ctd\u003e100 kA conforming to EN\/IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e4 A gG output\u003cbr\u003e0.5 A gG control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eThermal overload protection\u003cbr\u003eOverload\u003cbr\u003eThermal protection\u003cbr\u003eLocked rotor\u003cbr\u003ePhase failure\u003cbr\u003ePhase unbalance\u003cbr\u003eLoad fluctuation\u003cbr\u003eReverse polarity protection\u003cbr\u003eOverload (long time)\u003cbr\u003eEarth-leakage protection\u003cbr\u003ePower factor variation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork and machine diagnosis type\u003c\/td\u003e\n\u003ctd\u003eTrip context information\u003cbr\u003ePhase fault and earth fault trip counters\u003cbr\u003eTrip history information\u003cbr\u003eEvent recording\u003cbr\u003eRemaining operating time before overload tripping\u003cbr\u003eStarting current and time\u003cbr\u003eFault recording\u003cbr\u003eWaiting time after overload tripping\u003cbr\u003eRunning hours counter\/operating time\u003cbr\u003eMotor control command recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic input number\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current\u003c\/td\u003e\n\u003ctd\u003e3.1 mA 100 V\u003cbr\u003e7.5 mA 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent state 0 guaranteed\u003c\/td\u003e\n\u003ctd\u003eLogic input 0...40 V \u0026lt;= 15 mA 25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent state 1 guaranteed\u003c\/td\u003e\n\u003ctd\u003eLogic input 79...264 V \u0026gt;= 2 mA 25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum output switching frequency\u003c\/td\u003e\n\u003ctd\u003e2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad current\u003c\/td\u003e\n\u003ctd\u003e5 A 250 V AC logic output\u003cbr\u003e5 A 30 V DC logic output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible power\u003c\/td\u003e\n\u003ctd\u003e480 VA AC-15), Ie = 2 A, 500000 cycles output)\u003cbr\u003e30 W DC-13), Ie = 1.25 A, 500000 cycles output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e1800 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContacts type and composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC fault signal\u003cbr\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering type\u003c\/td\u003e\n\u003ctd\u003eEarth-fault current\u003cbr\u003eImbalance current\u003cbr\u003eTemperature\u003cbr\u003eAverage current Iavg\u003cbr\u003ePhase current I1, I2, I3 RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003e5...15 % earth fault current internal measurement\u003cbr\u003e1 % voltage 100...830 V)\u003cbr\u003e3 % power factor\u003cbr\u003e5 % earth fault current external measurement\u003cbr\u003e+\/- 30 min\/year internal clock\u003cbr\u003e0,02 Temperature\u003cbr\u003e1 % current\u003cbr\u003e5 % active and reactive power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection pitch\u003c\/td\u003e\n\u003ctd\u003e0.20 in (5.08 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit connector 1 0.0004â¦0.004 inÂ² (0.25â¦2.5 mmÂ²) AWG 24...AWG 14)flexible with cable end\u003cbr\u003eControl circuit connector 1 0.0003â¦0.004 inÂ² (0.2â¦2.5 mmÂ²) AWG 24...AWG 14)flexible without cable end\u003cbr\u003eControl circuit connector 1 0.0004â¦0.004 inÂ² (0.25â¦2.5 mmÂ²) AWG 24...AWG 14)flexible without cable end\u003cbr\u003eControl circuit connector 1 0.0003â¦0.004 inÂ² (0.2â¦2.5 mmÂ²) AWG 24...AWG 14)solid without cable end\u003cbr\u003eControl circuit connector 2 0.0003â¦0.002 inÂ² (0.2â¦1 mmÂ²) AWG 24...AWG 14)flexible with cable end\u003cbr\u003eControl circuit connector 2 0.0003â¦0.002 inÂ² (0.2â¦1.5 mmÂ²) AWG 24...AWG 14)flexible without cable end\u003cbr\u003eControl circuit connector 2 0.0008â¦0.002 inÂ² (0.5â¦1.5 mmÂ²) AWG 24...AWG 14)flexible without cable end\u003cbr\u003eControl circuit connector 2 0.0003â¦0.002 inÂ² (0.2â¦1 mmÂ²) AWG 24...AWG 14)solid without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit: 4.4â¦5.3 lbf.in (0.5â¦0.6 N.m) flat screwdriver 0.1 in (3 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epollution degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd\u003eElectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN\/IEC 61000-4-2\u003cbr\u003eRadiated RF fields, 3, 10 V\/m, conforming to EN\/IEC 61000-4-3\u003cbr\u003eFast transients immunity test (other circuits), level 3, 2 kV, conforming to EN\/IEC 61000-4-4\u003cbr\u003eFast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN\/IEC 61000-4-4\u003cbr\u003eVoltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN\/IEC 61000-4-11\u003cbr\u003eConducted RF disturbances, 10 V, conforming to EN\/IEC 61000-4-6\u003cbr\u003eTemperature sensor: surges (serial mode), 0.5 kV, conforming to EN\/IEC 61000-4-5\u003cbr\u003eTemperature sensor: surges (common mode), 1 kV, conforming to EN\/IEC 61000-4-5\u003cbr\u003eControl circuit: surges (serial mode), 1 kV, conforming to EN\/IEC 61000-4-5\u003cbr\u003eCommunication: surges (common mode), 2 kV, conforming to EN\/IEC 61000-4-5\u003cbr\u003eRelay outputs and supply: surges (serial mode), 2 kV, conforming to EN\/IEC 61000-4-5\u003cbr\u003eRelay outputs and supply: surges (common mode), 4 kV, conforming to EN\/IEC 61000-4-5\u003cbr\u003eControl circuit: surges (common mode), 2 kV, conforming to EN\/IEC 61000-4-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e3.6 in (91 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e2.4 in (61 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e4.8 in (122.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e1.17 lb(US) (0.53 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb services\u003c\/td\u003e\n\u003ctd\u003eWeb server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLTMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840653971678,"sku":"LTMR08EFM-Sealed","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Never Used Surplus","offer_id":42694250823902,"sku":"LTMR08EFM","price":8754.0,"currency_code":"SEK","in_stock":true},{"title":"Used","offer_id":42694250856670,"sku":"LTMR08EFM-Used","price":4612.0,"currency_code":"SEK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LTMR08EFM.jpg?v=1650048112","url":"https:\/\/plc-direct.com\/en-se\/products\/ltmr08efm","provider":"PLC Direct","version":"1.0","type":"link"}