{"product_id":"lc1skgc310e7","title":"LC1SKGC310E7 Schneider Electric","description":"\u003cp\u003eTeSys SKGC mini-contactor, 3 poles (3NO), for non-inductive load applications up to 20A\/690V AC-1, and for 3-phase motor control applications up to 9A\/690V AC-3 (4kW@400V). It provides a 48V 50\/60Hz AC control circuit, 1NO auxiliary contact, a transparent protective cover to prevent front face access, connection by screw terminals. For operating rates until 1200 cycles\/hour and ambient temperature -20\/+50Â°C, it procures high reliability and durability. For use in modular panels, compact (45mm width), clipping on 35mm DIN rail or fixing by 2 screws. Location available to insert a suppressor module LA4SK (to be ordered separately). Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS\/REACh).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003eTeSys SK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eMini contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1SKGC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eResistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-3\u003cbr\u003eAC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epower pole contact composition\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e20 A (at \u0026lt;122 Â°F (50 Â°C)) AC AC-1\u003cbr\u003e9 A at \u0026lt;= 400 V AC AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit 690 V AC 50\/60 Hz\u003cbr\u003eSignalling circuit 690 V AC \u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e48 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e4 kW at 380...415 V AC 50\/60 Hz\u003cbr\u003e4 kW at 660...690 V AC 50\/60 Hz\u003cbr\u003e1.1 kW at 220...230 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e20 A (at 131 Â°F (55 Â°C)) for power circuit\u003cbr\u003e10 A (at 131 Â°F (55 Â°C)) for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e85 A AC conforming to NF C 63-110\u003cbr\u003e85 A AC conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e68 A at \u0026lt;= 400 V conforming to NF C 63-110\u003cbr\u003e68 A at \u0026lt;= 400 V conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e60 A 131 Â°F (55 Â°C) for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e20 A gI at \u0026lt;= 440 V for power circuit\u003cbr\u003e10 A gI for signalling circuit conforming to IEC 60947\u003cbr\u003e10 A gI for signalling circuit conforming to VDE 0660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e4 mOhm - Ith 20 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit 690 V BS 5424\u003cbr\u003ePower circuit 690 V IEC 60947\u003cbr\u003ePower circuit 690 V UL 508\u003cbr\u003ePower circuit 690 V VDE 0110 group C\u003cbr\u003ePower circuit 690 V CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eRail\u003cbr\u003ePanel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-4-1\u003cbr\u003eUL 60947-4-1\u003cbr\u003eCSA C22.2 No 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCB Scheme\u003cbr\u003eCE\u003cbr\u003eUKCA\u003cbr\u003eEAC\u003cbr\u003ecULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003econnector 1 0.002â¦0.009 inÂ² (1.5â¦6 mmÂ²)solid\u003cbr\u003e connector 2 0.002â¦0.006 inÂ² (1.5â¦4 mmÂ²)solid\u003cbr\u003e connector 1 0.0008â¦0.009 inÂ² (0.5â¦6 mmÂ²)flexible without cable end\u003cbr\u003e connector 2 0.0005â¦0.004 inÂ² (0.35â¦2.5 mmÂ²)flexible without cable end\u003cbr\u003e connector 1 0.0005â¦0.009 inÂ² (0.35â¦6 mmÂ²)flexible with cable end\u003cbr\u003e connector 2 0.0005â¦0.002 inÂ² (0.35â¦1.5 mmÂ²)flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003ePower circuit 7.08 lbf.in (0.8 N.m) connector pozidriv No 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e6...8 ms coil de-energisation and NO opening\u003cbr\u003e7...14 ms coil energisation and NO closing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e10 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e1200 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003eOperational: 0.85...1.1 Uc at 50\/60 Hz (at \u0026lt;131 Â°F (55 Â°C))\u003cbr\u003eDrop-out: 0.2...0.75 Uc at 50\/60 Hz (at \u0026lt;131 Â°F (55 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in VA\u003c\/td\u003e\n\u003ctd\u003e23 VA 50\/60 Hz (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e4.9 VA 50\/60 Hz (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e1.5 W 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignalling circuit frequency\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840636244190,"sku":"LC1SKGC310E7-Sealed","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Never Used Surplus","offer_id":42680833867998,"sku":"LC1SKGC310E7","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Used","offer_id":42680833900766,"sku":"LC1SKGC310E7-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LC1SKGC310E7.jpg?v=1649787704","url":"https:\/\/plc-direct.com\/en-se\/products\/lc1skgc310e7","provider":"PLC Direct","version":"1.0","type":"link"}