{"product_id":"lc1k1610m7","title":"LC1K1610M7 Schneider Electric","description":"\u003cp\u003eTeSys K contactor, 3 poles (3NO), for motor control applications up to 16A\/690V AC-3 (7.5kW@400V). It provides a 220V 50\/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles\/hour and environments until 50Â°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice application\u003c\/td\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-3\u003cbr\u003eAC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epower pole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit: \u0026lt;= 690 V AC \u0026lt;= 400 Hz\u003cbr\u003eSignalling circuit: \u0026lt;= 690 V AC \u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e16 A (at \u0026lt;60 Â°C) at \u0026lt;= 440 V AC AC-3 for power circuit\u003cbr\u003e16 A (at \u0026lt;60 Â°C) at \u0026lt;= 440 V AC AC-3e for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eAC at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e220...230 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e4 kW at 220...230 V AC 50\/60 Hz AC-3\u003cbr\u003e7.5 kW at 380...415 V AC 50\/60 Hz AC-3\u003cbr\u003e5.5 kW at 440 V AC 50\/60 Hz AC-3\u003cbr\u003e4 kW at 690 V AC 50\/60 Hz AC-3\u003cbr\u003e4 kW at 220...230 V AC 50\/60 Hz AC-3e\u003cbr\u003e7.5 kW at 380...415 V AC 50\/60 Hz AC-3e\u003cbr\u003e5.5 kW at 440 V AC 50\/60 Hz AC-3e\u003cbr\u003e4 kW at 690 V AC 50\/60 Hz AC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e20 A (at 60 Â°C) for power circuit\u003cbr\u003e10 A (at 50 Â°C) for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e160 A AC for power circuit conforming to IEC 60947\u003cbr\u003e110 A AC for signalling circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e110 A at 440 V conforming to IEC 60947\u003cbr\u003e80 A at 500 V conforming to IEC 60947\u003cbr\u003e70 A at 660...690 V conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e115 A 50 Â°C - 1 s for power circuit\u003cbr\u003e105 A 50 Â°C - 5 s for power circuit\u003cbr\u003e100 A 50 Â°C - 10 s for power circuit\u003cbr\u003e75 A 50 Â°C - 30 s for power circuit\u003cbr\u003e55 A 50 Â°C - 1 min for power circuit\u003cbr\u003e50 A 50 Â°C - 3 min for power circuit\u003cbr\u003e25 A 50 Â°C - \u0026gt;= 15 min for power circuit\u003cbr\u003e80 A - 1 s for signalling circuit\u003cbr\u003e90 A - 500 ms for signalling circuit\u003cbr\u003e110 A - 100 ms for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e25 A gG at \u0026lt;= 440 V for power circuit\u003cbr\u003e25 A aM for power circuit\u003cbr\u003e10 A gG for signalling circuit conforming to IEC 60947\u003cbr\u003e10 A gG for signalling circuit conforming to VDE 0660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e3 mOhm - Ith 20 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit: 600 V conforming to UL 508\u003cbr\u003ePower circuit: 690 V conforming to IEC 60947-4-1\u003cbr\u003eSignalling circuit: 690 V conforming to IEC 60947-4-1\u003cbr\u003eSignalling circuit: 690 V conforming to IEC 60947-5-1\u003cbr\u003eSignalling circuit: 600 V conforming to UL 508\u003cbr\u003ePower circuit: 600 V conforming to CSA C22.2 No 14\u003cbr\u003eSignalling circuit: 600 V conforming to CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in VA\u003c\/td\u003e\n\u003ctd\u003e30 VA (at 20 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e4.5 VA (at 20 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e1.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003eOperational: 0.8...1.15 Uc (at \u0026lt;50 Â°C)\u003cbr\u003eDrop-out: \u0026gt;= 0.20 Uc (at \u0026lt;50 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals 1 cable(s) 1.5â¦4 mmÂ²solid\u003cbr\u003eScrew clamp terminals 1 cable(s) 0.75â¦4 mmÂ²flexible without cable end\u003cbr\u003eScrew clamp terminals 1 cable(s) 0.34â¦2.5 mmÂ²flexible with cable end\u003cbr\u003eScrew clamp terminals 2 cable(s) 1.5â¦4 mmÂ²solid\u003cbr\u003eScrew clamp terminals 2 cable(s) 0.75â¦4 mmÂ²flexible without cable end\u003cbr\u003eScrew clamp terminals 2 cable(s) 0.34â¦1.5 mmÂ²flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003etype instantaneous 1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignalling circuit frequency\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003ePlate\u003cbr\u003eRail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e0.8â¦1.3 N.m - on screw clamp terminals Philips No 2\u003cbr\u003e0.8â¦1.3 N.m - on screw clamp terminals flat Ã 6 mm\u003cbr\u003e0.8â¦1.3 N.m - on screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e10...20 ms coil de-energisation and NO opening\u003cbr\u003e10...20 ms coil energisation and NO closing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load conforming to EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load conforming to EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon overlap distance\u003c\/td\u003e\n\u003ctd\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e10 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e1.3 Mcycles 16 A AC-3 at Ue \u0026lt;= 440 V\u003cbr\u003e1.3 Mcycles 16 A AC-3e at Ue \u0026lt;= 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical robustness\u003c\/td\u003e\n\u003ctd\u003eShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27\u003cbr\u003eShocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27\u003cbr\u003eShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27\u003cbr\u003eShocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27\u003cbr\u003eShocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27\u003cbr\u003eShocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27\u003cbr\u003eVibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6\u003cbr\u003eVibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct weight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840635326686,"sku":"LC1K1610M7-Sealed","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Never Used Surplus","offer_id":42680831246558,"sku":"LC1K1610M7","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Used","offer_id":42680831279326,"sku":"LC1K1610M7-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LC1K1610M7.jpg?v=1649787666","url":"https:\/\/plc-direct.com\/en-se\/products\/lc1k1610m7","provider":"PLC Direct","version":"1.0","type":"link"}