{"product_id":"lc1k0910g7","title":"LC1K0910G7 Schneider Electric","description":"\u003cp\u003eTeSys K contactors have been designed for perfect integration into control systems. They can be used to create motor starters for any type of application. They can be used to create motor starters for almost any type of application. TeSys K contactors offer quick simple setup, while maintaining a compact size. Contactors have both Horsepower and Kw motor rating for international acceptance. An extennsive line of accessories makes it easy to meet the requirements of most applications. These contactors are UL Listed and CSA certified. Multi standards certified (IEC, UL, CSA, CCC, EAC).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eResistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-3\u003cbr\u003eAC-3e\u003cbr\u003eAC-1\u003cbr\u003eAC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epower pole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit \u0026lt;= 690 V AC \u0026lt;= 400 Hz\u003cbr\u003eSignalling circuit \u0026lt;= 690 V AC \u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e9 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3 for power circuit\u003cbr\u003e9 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3e for power circuit\u003cbr\u003e20 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 690 V AC AC-1 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e120 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e2.2 kW 220...230 V AC 50\/60 Hz AC-3\u003cbr\u003e4 kW 380...415 V AC 50\/60 Hz AC-3\u003cbr\u003e4 kW 440\/690 V AC 50\/60 Hz AC-3\u003cbr\u003e2.2 kW 220...230 V AC 50\/60 Hz AC-3e\u003cbr\u003e4 kW 380...415 V AC 50\/60 Hz AC-3e\u003cbr\u003e4 kW 440\/690 V AC 50\/60 Hz AC-3e\u003cbr\u003e2.2 kW 220...230 V AC 50\/60 Hz AC-4\u003cbr\u003e4 kW 380...415 V AC 50\/60 Hz AC-4\u003cbr\u003e4 kW 440\/690 V AC 50\/60 Hz AC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e20 A (at 140 Â°F (60 Â°C)) for power circuit\u003cbr\u003e10 A (at 122 Â°F (50 Â°C)) for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e110 A AC for power circuit conforming to IEC 60947\u003cbr\u003e110 A AC for signalling circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e110 A at 220...230 V conforming to IEC 60947\u003cbr\u003e110 A at 380...400 V conforming to IEC 60947\u003cbr\u003e110 A at 415 V conforming to IEC 60947\u003cbr\u003e110 A at 440 V conforming to IEC 60947\u003cbr\u003e80 A at 500 V conforming to IEC 60947\u003cbr\u003e70 A at 660...690 V conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e90 A 122 Â°F (50 Â°C) - 1 s for power circuit\u003cbr\u003e85 A 122 Â°F (50 Â°C) - 5 s for power circuit\u003cbr\u003e80 A 122 Â°F (50 Â°C) - 10 s for power circuit\u003cbr\u003e60 A 122 Â°F (50 Â°C) - 30 s for power circuit\u003cbr\u003e45 A 122 Â°F (50 Â°C) - 1 min for power circuit\u003cbr\u003e40 A 122 Â°F (50 Â°C) - 3 min for power circuit\u003cbr\u003e20 A 122 Â°F (50 Â°C) - \u0026gt;= 15 min for power circuit\u003cbr\u003e80 A - 1 s for signalling circuit\u003cbr\u003e90 A - 500 ms for signalling circuit\u003cbr\u003e110 A - 100 ms for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e25 A gG at \u0026lt;= 440 V for power circuit\u003cbr\u003e25 A aM for power circuit\u003cbr\u003e10 A gG for signalling circuit conforming to IEC 60947\u003cbr\u003e10 A gG for signalling circuit conforming to VDE 0660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e3 mOhm - Ith 20 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in VA\u003c\/td\u003e\n\u003ctd\u003e30 VA (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e4.5 VA (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e1.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003eOperational: 0.8...1.15 Uc (at \u0026lt;122 Â°F (50 Â°C))\u003cbr\u003eDrop-out: \u0026gt;= 0.20 Uc (at \u0026lt;122 Â°F (50 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003escrew clamp terminals 1 0.002â¦0.006 inÂ² (1.5â¦4 mmÂ²)solid\u003cbr\u003e screw clamp terminals 1 0.001â¦0.006 inÂ² (0.75â¦4 mmÂ²)flexible without cable end\u003cbr\u003e screw clamp terminals 1 0.0005â¦0.004 inÂ² (0.34â¦2.5 mmÂ²)flexible with cable end\u003cbr\u003e screw clamp terminals 2 0.002â¦0.006 inÂ² (1.5â¦4 mmÂ²)solid\u003cbr\u003e screw clamp terminals 2 0.001â¦0.006 inÂ² (0.75â¦4 mmÂ²)flexible without cable end\u003cbr\u003e screw clamp terminals 2 0.0005â¦0.002 inÂ² (0.34â¦1.5 mmÂ²)flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003eInstantaneous 1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignalling circuit frequency\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e10...20 ms coil de-energisation and NO opening\u003cbr\u003e10...20 ms coil energisation and NO closing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon overlap distance\u003c\/td\u003e\n\u003ctd\u003e0.02 in (0.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e10 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e1.3 Mcycles 9 A AC-3 \u0026lt;= 440 V\u003cbr\u003e1.3 Mcycles 9 A AC-3e \u0026lt;= 440 V\u003cbr\u003e0.16 Mcycles 20 A AC-1 \u0026lt;= 690 V\u003cbr\u003e0.02 Mcycles 54 A AC-4 \u0026lt;= 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical robustness\u003c\/td\u003e\n\u003ctd\u003eShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27\u003cbr\u003eShocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27\u003cbr\u003eShocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27\u003cbr\u003eShocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27\u003cbr\u003eShocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27\u003cbr\u003eShocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27\u003cbr\u003eVibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6\u003cbr\u003eVibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e2.3 in (58 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.8 in (45 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e2.2 in (57 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840633589982,"sku":"LC1K0910G7-Sealed","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Never Used Surplus","offer_id":42680825938142,"sku":"LC1K0910G7","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Used","offer_id":42680825970910,"sku":"LC1K0910G7-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LC1K0910G7.jpg?v=1649787556","url":"https:\/\/plc-direct.com\/en-se\/products\/lc1k0910g7","provider":"PLC Direct","version":"1.0","type":"link"}