{"product_id":"lc1k09016bls207","title":"LC1K09016BLS207 Schneider Electric","description":"\u003cp\u003eTeSys K contactor, 3P(3NO) for category AC-3 motor control applications up to 9A @440V. It is fully compliant with railway standards. It procures high reliability and durability with 30 Mcycles mechanical durability and 1.3 Mcycles electrical durability. It provides IP20 protection confirming to VDE 0106. It can cover up to 50Â°C operation temperature under 2000m altitude without derating . Designed for demanding applications with maximum operating rates up to 3600 cycles\/hr. The dimension is 58mm x 45mm x 57mm (H x W x D), mounting on rail or plate. Multi international standards certified, Green Premium product (RoHS\/REACh).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice application\u003c\/td\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eResistive load\u003cbr\u003eMotor control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-3\u003cbr\u003eAC-3e\u003cbr\u003eAC-1\u003cbr\u003eAC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epower pole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit: \u0026lt;= 690 V AC \u0026lt;= 400 Hz\u003cbr\u003eSignalling circuit: \u0026lt;= 690 V AC \u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e9 A (at \u0026lt;60 Â°C) at \u0026lt;= 440 V AC AC-3 for power circuit\u003cbr\u003e9 A (at \u0026lt;60 Â°C) at \u0026lt;= 440 V AC AC-3e for power circuit\u003cbr\u003e20 A (at \u0026lt;60 Â°C) at \u0026lt;= 690 V AC AC-1 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eDC low consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e2.2 kW at 220...230 V AC 50\/60 Hz AC-3\u003cbr\u003e4 kW at 380...415 V AC 50\/60 Hz AC-3\u003cbr\u003e4 kW at 440\/690 V AC 50\/60 Hz AC-3\u003cbr\u003e2.2 kW at 220...230 V AC 50\/60 Hz AC-3e\u003cbr\u003e4 kW at 380...415 V AC 50\/60 Hz AC-3e\u003cbr\u003e4 kW at 440\/690 V AC 50\/60 Hz AC-3e\u003cbr\u003e2.2 kW at 220...230 V AC 50\/60 Hz AC-4\u003cbr\u003e4 kW at 380...415 V AC 50\/60 Hz AC-4\u003cbr\u003e4 kW at 440\/690 V AC 50\/60 Hz AC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e20 A (at 60 Â°C) for power circuit\u003cbr\u003e10 A (at 50 Â°C) for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e110 A AC for power circuit conforming to IEC 60947\u003cbr\u003e110 A AC for signalling circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e110 A at 220...230 V conforming to IEC 60947\u003cbr\u003e110 A at 380...400 V conforming to IEC 60947\u003cbr\u003e110 A at 415 V conforming to IEC 60947\u003cbr\u003e110 A at 440 V conforming to IEC 60947\u003cbr\u003e80 A at 500 V conforming to IEC 60947\u003cbr\u003e70 A at 660...690 V conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e90 A 50 Â°C - 1 s for power circuit\u003cbr\u003e85 A 50 Â°C - 5 s for power circuit\u003cbr\u003e80 A 50 Â°C - 10 s for power circuit\u003cbr\u003e60 A 50 Â°C - 30 s for power circuit\u003cbr\u003e45 A 50 Â°C - 1 min for power circuit\u003cbr\u003e40 A 50 Â°C - 3 min for power circuit\u003cbr\u003e20 A 50 Â°C - \u0026gt;= 15 min for power circuit\u003cbr\u003e80 A - 1 s for signalling circuit\u003cbr\u003e90 A - 500 ms for signalling circuit\u003cbr\u003e110 A - 100 ms for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e25 A gG at \u0026lt;= 440 V for power circuit\u003cbr\u003e10 A gG for signalling circuit conforming to IEC 60947\u003cbr\u003e10 A gG for signalling circuit conforming to VDE 0660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e3 mOhm - Ith 20 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit: 690 V conforming to IEC 60947-4-1\u003cbr\u003eSignalling circuit: 690 V conforming to IEC 60947-4-1\u003cbr\u003eSignalling circuit: 690 V conforming to IEC 60947-5-1\u003cbr\u003ePower circuit: 750 V conforming to VDE 0110 group C\u003cbr\u003ePower circuit: 690 V conforming to BS 5424\u003cbr\u003ePower circuit: 690 V conforming to NF C 20-040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esafety cover\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in W\u003c\/td\u003e\n\u003ctd\u003e1.8 W (at 20 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in W\u003c\/td\u003e\n\u003ctd\u003e1.8 W at 20 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e1.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003eOperational: 0.7...1.3 Uc (at \u0026lt;50 Â°C)\u003cbr\u003eDrop-out: \u0026gt;= 0.10 Uc (at \u0026lt;50 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003ePower circuit: lugs-ring terminals (external diameter: 7 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eWith integral suppression device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003etype instantaneous 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignalling circuit frequency\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003eRail\u003cbr\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003ePower circuit: 0.8â¦1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm flat Ã 6 mm\u003cbr\u003ePower circuit: 0.8â¦1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm Philips No 2\u003cbr\u003ePower circuit: 0.8â¦1.3 N.m - on lugs-ring terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e10...20 ms coil de-energisation and NO opening\u003cbr\u003e30...40 ms coil energisation and NO closing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load conforming to EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load conforming to EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon overlap distance\u003c\/td\u003e\n\u003ctd\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e30 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e0.18 Mcycles 20 A AC-1 at Ue \u0026lt;= 440 V\u003cbr\u003e1.3 Mcycles 9 A AC-3 at Ue \u0026lt;= 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical robustness\u003c\/td\u003e\n\u003ctd\u003eShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27\u003cbr\u003eShocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27\u003cbr\u003eShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27\u003cbr\u003eShocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27\u003cbr\u003eShocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27\u003cbr\u003eShocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27\u003cbr\u003eVibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6\u003cbr\u003eVibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct weight\u003c\/td\u003e\n\u003ctd\u003e0.235 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840632639710,"sku":"LC1K09016BLS207-Sealed","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Never Used Surplus","offer_id":42680823283934,"sku":"LC1K09016BLS207","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Used","offer_id":42680823316702,"sku":"LC1K09016BLS207-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LC1K09016BLS207.jpg?v=1649787499","url":"https:\/\/plc-direct.com\/en-se\/products\/lc1k09016bls207","provider":"PLC Direct","version":"1.0","type":"link"}