{"product_id":"lc1d95d7","title":"LC1D95D7 Schneider Electric","description":"\u003cp\u003e\"TeSys Deca contactor, 3P(3NO) for category AC-3\/AC-3e applications up to 95A @440V.\" It provides with 42V 50\/60 Hz coil, with 1NO+1NC auxiliary contacts, power and control connections by screw clamp terminals. It procures with 4 Mcycles mechanical durability and 1.2 Mcycles electrical durability. It provides IP20 protection on front face conforming to IEC 60529. It can cover -40Â°C to 60Â°C operation temperature and without derating under 3000m altitude. Designed for demanding applications with maximum operating rates up to 3600 cycles per hour under maximum 60Â°C. The dimension is 127mm x 85mm x 130mm (H x W x D), mounting on rail or plate. Multi standards certified(CCC,BV,RINA,DNV-GL,LROS,CB,EAC,CSA).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of product\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eResistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-3\u003cbr\u003eAC-3e\u003cbr\u003eAC-4\u003cbr\u003eAC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit: \u0026lt;= 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e95 A (at \u0026lt;60 Â°C) at \u0026lt;= 440 V AC-3 for power circuit\u003cbr\u003e125 A (at \u0026lt;60 Â°C) at \u0026lt;= 690 V AC-1 for power circuit\u003cbr\u003e95 A (at \u0026lt;60 Â°C) at \u0026lt;= 440 V AC-3e for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e42 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e25 kW at 220...230 V AC 50 Hz (AC-3)\u003cbr\u003e45 kW at 380...400 V AC 50 Hz (AC-3)\u003cbr\u003e45 kW at 415...440 V AC 50 Hz (AC-3)\u003cbr\u003e55 kW at 500 V AC 50 Hz (AC-3)\u003cbr\u003e45 kW at 660...690 V AC 50 Hz (AC-3)\u003cbr\u003e15 kW at 400 V AC 50 Hz (AC-4)\u003cbr\u003e25 kW at 220...230 V AC 50 Hz (AC-3e)\u003cbr\u003e45 kW at 380...400 V AC 50 Hz (AC-3e)\u003cbr\u003e45 kW at 415...440 V AC 50 Hz (AC-3e)\u003cbr\u003e55 kW at 500 V AC 50 Hz (AC-3e)\u003cbr\u003e45 kW at 660...690 V AC 50 Hz (AC-3e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power hp\u003c\/td\u003e\n\u003ctd\u003e7.5 hp at 120 V AC 60 Hz for 1 phase motors\u003cbr\u003e15 hp at 230\/240 V AC 60 Hz for 1 phase motors\u003cbr\u003e30 hp at 200\/208 V AC 60 Hz for 3 phases motors\u003cbr\u003e30 hp at 230\/240 V AC 60 Hz for 3 phases motors\u003cbr\u003e60 hp at 460\/480 V AC 60 Hz for 3 phases motors\u003cbr\u003e60 hp at 575\/600 V AC 60 Hz for 3 phases motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective cover\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e10 A (at 60 Â°C) for signalling circuit\u003cbr\u003e125 A (at 60 Â°C) for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e1100 A at 440 V AC for power circuit conforming to IEC 60947\u003cbr\u003e140 A AC for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e250 A DC for signalling circuit conforming to IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e1100 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e1100 A 40 Â°C - 1 s for power circuit\u003cbr\u003e800 A 40 Â°C - 10 s for power circuit\u003cbr\u003e400 A 40 Â°C - 1 min for power circuit\u003cbr\u003e135 A 40 Â°C - 10 min for power circuit\u003cbr\u003e140 A - 100 ms for signalling circuit\u003cbr\u003e120 A - 500 ms for signalling circuit\u003cbr\u003e100 A - 1 s for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e10 A gG for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e200 A gG at \u0026lt;= 690 V coordination type 1 for power circuit\u003cbr\u003e160 A gG at \u0026lt;= 690 V coordination type 2 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e0.8 mOhm - Ith 125 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e12.5 W AC-1\u003cbr\u003e7.2 W AC-3\u003cbr\u003e7.2 W AC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit: 1000 V conforming to IEC 60947-4-1\u003cbr\u003ePower circuit: 600 V CSA certified\u003cbr\u003ePower circuit: 600 V UL certified\u003cbr\u003eSignalling circuit: 690 V conforming to IEC 60947-1\u003cbr\u003eSignalling circuit: 600 V CSA certified\u003cbr\u003eSignalling circuit: 600 V UL certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epollution degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1.3 Mcycles contactor with nominal load conforming to EN\/ISO 13849-1\u003cbr\u003eB10d = 20 Mcycles contactor with mechanical load conforming to EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e4 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e1.2 Mcycles 95 A AC-3\u003cbr\u003e1.3 Mcycles 125 A AC-1\u003cbr\u003e1.2 Mcycles 95 A AC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eAC at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eWithout built-in suppressor module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e0.8...1.1 Uc (-40â¦55 Â°C):operational AC 50 Hz\u003cbr\u003e0.85...1.1 Uc (-40â¦55 Â°C):operational AC 60 Hz\u003cbr\u003e0.3...0.6 Uc (-40â¦70 Â°C):drop-out AC 50\/60 Hz\u003cbr\u003e1...1.1 Uc (55â¦70 Â°C):operational AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in VA\u003c\/td\u003e\n\u003ctd\u003e245 VA 60 Hz cos phi 0.75 (at 20 Â°C)\u003cbr\u003e245 VA 50 Hz cos phi 0.75 (at 20 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e26 VA 60 Hz cos phi 0.3 (at 20 Â°C)\u003cbr\u003e26 VA 50 Hz cos phi 0.3 (at 20 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e6â¦10 W at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e20...35 ms closing\u003cbr\u003e6...20 ms opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h at 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit: screw clamp terminals 2 1â¦2.5 mmÂ² - cable stiffness: flexible with cable end\u003cbr\u003eControl circuit: screw clamp terminals 1 1â¦2.5 mmÂ² - cable stiffness: flexible with cable end\u003cbr\u003eControl circuit: screw clamp terminals 1 1â¦4 mmÂ² - cable stiffness: flexible without cable end\u003cbr\u003eControl circuit: screw clamp terminals 2 1â¦4 mmÂ² - cable stiffness: flexible without cable end\u003cbr\u003eControl circuit: screw clamp terminals 1 1â¦4 mmÂ² - cable stiffness: solid without cable end\u003cbr\u003eControl circuit: screw clamp terminals 2 1â¦4 mmÂ² - cable stiffness: solid without cable end\u003cbr\u003ePower circuit: connector 1 4â¦50 mmÂ² - cable stiffness: flexible without cable end\u003cbr\u003ePower circuit: connector 2 4â¦25 mmÂ² - cable stiffness: flexible without cable end\u003cbr\u003ePower circuit: connector 1 4â¦50 mmÂ² - cable stiffness: flexible with cable end\u003cbr\u003ePower circuit: connector 2 4â¦16 mmÂ² - cable stiffness: flexible with cable end\u003cbr\u003ePower circuit: connector 1 4â¦50 mmÂ² - cable stiffness: solid without cable end\u003cbr\u003ePower circuit: connector 2 4â¦25 mmÂ² - cable stiffness: solid without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ã 6 mm\u003cbr\u003eControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2\u003cbr\u003ePower circuit: 12 N.m - on connector - with screwdriver flat Ã 6 to Ã 8 mm\u003cbr\u003ePower circuit: 12 N.m - on connector hexagonal screw head 4 mm\u003cbr\u003eControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003etype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1\u003cbr\u003e type mirror contact 1 NC conforming to IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignalling circuit frequency\u003c\/td\u003e\n\u003ctd\u003e25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-overlap time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms on de-energisation between NC and NO contact\u003cbr\u003e1.5 ms on energisation between NC and NO contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003ePlate\u003cbr\u003eRail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840616190174,"sku":"LC1D95D7-Sealed","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Never Used Surplus","offer_id":42659392389342,"sku":"LC1D95D7","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Used","offer_id":42659392422110,"sku":"LC1D95D7-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LC1D95D7.jpg?v=1649346704","url":"https:\/\/plc-direct.com\/en-se\/products\/lc1d95d7","provider":"PLC Direct","version":"1.0","type":"link"}