{"product_id":"lc1d25g7","title":"LC1D25G7 Schneider","description":"\u003cp\u003eTeSys Deca contactor, 3 poles (3NO), for motor control applications up to 25A\/690V AC-3\/3e (11kW@400V). They can be used to create motor starters for almost any type of application. It provides a 120V 50\/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles\/hour and environments until 60Â°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 7.5HP at 200-208VAC, 7.5HP at 240VAC, 15HP at 480VAC and 20HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 60A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 120 VAC 50\/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.82 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eResistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-3\u003cbr\u003eAC-4\u003cbr\u003eAC-1\u003cbr\u003eAC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit \u0026lt;= 690 V AC 25...400 Hz\u003cbr\u003ePower circuit \u0026lt;= 300 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e25 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3 for power circuit\u003cbr\u003e40 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-1 for power circuit\u003cbr\u003e25 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3e for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e120 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e5.5 kW at 220...230 V AC 50\/60 Hz (AC-3)\u003cbr\u003e11 kW at 380...400 V AC 50\/60 Hz (AC-3)\u003cbr\u003e11 kW at 415...440 V AC 50\/60 Hz (AC-3)\u003cbr\u003e15 kW at 500 V AC 50\/60 Hz (AC-3)\u003cbr\u003e15 kW at 660...690 V AC 50\/60 Hz (AC-3)\u003cbr\u003e5.5 kW at 400 V AC 50\/60 Hz (AC-4)\u003cbr\u003e5.5 kW at 220...230 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e11 kW at 380...400 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e11 kW at 415...440 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e15 kW at 500 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e15 kW at 660...690 V AC 50\/60 Hz (AC-3e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Horse Power Rating\u003c\/td\u003e\n\u003ctd\u003e3 hp at 230\/240 V AC 50\/60 Hz for 1 phase motors\u003cbr\u003e2 hp at 115 V AC 50\/60 Hz for 1 phase motors\u003cbr\u003e7.5 hp at 230\/240 V AC 50\/60 Hz for 3 phase motors\u003cbr\u003e15 hp at 460\/480 V AC 50\/60 Hz for 3 phase motors\u003cbr\u003e20 hp at 575\/600 V AC 50\/60 Hz for 3 phase motors\u003cbr\u003e7.5 hp at 200\/208 V AC 50\/60 Hz for 3 phase motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective cover\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e10 A (at 140 Â°F (60 Â°C)) for signalling circuit\u003cbr\u003e40 A (at 140 Â°F (60 Â°C)) for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e140 A AC for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e250 A DC for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e450 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e450 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e240 A 104 Â°F (40 Â°C) - 10 s for power circuit\u003cbr\u003e380 A 104 Â°F (40 Â°C) - 1 s for power circuit\u003cbr\u003e50 A 104 Â°F (40 Â°C) - 10 min for power circuit\u003cbr\u003e120 A 104 Â°F (40 Â°C) - 1 min for power circuit\u003cbr\u003e100 A - 1 s for signalling circuit\u003cbr\u003e120 A - 500 ms for signalling circuit\u003cbr\u003e140 A - 100 ms for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e10 A gG for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e63 A gG at \u0026lt;= 690 V coordination type 1 for power circuit\u003cbr\u003e40 A gG at \u0026lt;= 690 V coordination type 2 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e2 mOhm - Ith 40 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e3.2 W AC-1\u003cbr\u003e1.25 W AC-3\u003cbr\u003e1.25 W AC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit 690 V IEC 60947-4-1\u003cbr\u003ePower circuit 600 V CSA\u003cbr\u003ePower circuit 600 V UL\u003cbr\u003eSignalling circuit 690 V IEC 60947-1\u003cbr\u003eSignalling circuit 600 V CSA\u003cbr\u003eSignalling circuit 600 V UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epollution degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e15 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e1.65 Mcycles 25 A AC-3 \u0026lt;= 440 V\u003cbr\u003e1.4 Mcycles 40 A AC-1 \u0026lt;= 440 V\u003cbr\u003e1.65 Mcycles 25 A AC-3e \u0026lt;= 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eWithout built-in suppressor module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e0.3...0.6 Uc (-40â¦158 Â°F (-40â¦70 Â°C)):drop-out AC 50\/60 Hz\u003cbr\u003e0.8...1.1 Uc (-40â¦140 Â°F (-40â¦60 Â°C)):operational AC 50 Hz\u003cbr\u003e0.85...1.1 Uc (-40â¦140 Â°F (-40â¦60 Â°C)):operational AC 60 Hz\u003cbr\u003e1...1.1 Uc (140â¦158 Â°F (60â¦70 Â°C)):operational AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in VA\u003c\/td\u003e\n\u003ctd\u003e70 VA 60 Hz cos phi 0.75 (at 68 Â°F (20 Â°C))\u003cbr\u003e70 VA 50 Hz cos phi 0.75 (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e7.5 VA 60 Hz cos phi 0.3 (at 68 Â°F (20 Â°C))\u003cbr\u003e7 VA 50 Hz cos phi 0.3 (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e2â¦3 W at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e12...22 ms closing\u003cbr\u003e4...19 ms opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h at 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit: screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003eControl circuit: screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003eControl circuit: screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003eControl circuit: screw clamp terminals 2 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003eControl circuit: screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: solid without cable end\u003cbr\u003eControl circuit: screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²) - cable stiffness: solid without cable end\u003cbr\u003ePower circuit: screw clamp terminals 1 0.004â¦0.02 inÂ² (2.5â¦10 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003ePower circuit: screw clamp terminals 2 0.004â¦0.02 inÂ² (2.5â¦10 mmÂ²) - cable stiffness: flexible without cable end\u003cbr\u003ePower circuit: screw clamp terminals 1 0.002â¦0.02 inÂ² (1â¦10 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003ePower circuit: screw clamp terminals 2 0.002â¦0.009 inÂ² (1.5â¦6 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003ePower circuit: screw clamp terminals 1 0.002â¦0.02 inÂ² (1.5â¦10 mmÂ²) - cable stiffness: solid without cable end\u003cbr\u003ePower circuit: screw clamp terminals 2 0.004â¦0.02 inÂ² (2.5â¦10 mmÂ²) - cable stiffness: solid without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ã 6 mm\u003cbr\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2\u003cbr\u003ePower circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals flat Ã 6 mm\u003cbr\u003ePower circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals Philips No 2\u003cbr\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2\u003cbr\u003ePower circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003eMechanically linked 1 NO + 1 NC IEC 60947-5-1\u003cbr\u003eMirror contact 1 NC IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignalling circuit frequency\u003c\/td\u003e\n\u003ctd\u003e25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-overlap time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms on de-energisation between NC and NO contact\u003cbr\u003e1.5 ms on energisation between NC and NO contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eRail\u003cbr\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840600101086,"sku":"LC1D25G7-Sealed","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Never Used Surplus","offer_id":46487507370206,"sku":"LC1D25G7","price":3846.0,"currency_code":"SEK","in_stock":true},{"title":"Used","offer_id":46487507402974,"sku":"LC1D25G7-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_b4dd93c9-9003-452a-af98-3297f800bd21.png?v=1753948913","url":"https:\/\/plc-direct.com\/en-se\/products\/lc1d25g7","provider":"PLC Direct","version":"1.0","type":"link"}