{"product_id":"lc1d096fls207","title":"LC1D096FLS207 Schneider Electric","description":"\u003cp\u003eTeSys D contactor, 3 poles (3NO), for motor control in railway applications up to 9A\/690V AC-3\/3e (4kW@400V). It provides a 110V DC low consumption coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts, connection by ring-lugs screw terminals. It procures high reliability and durability with 3600 cycles\/hour operating rates under 60Â°C environment temperature. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, CCC, EAC) and compliant with the railway European standard EN 45545 R22HL3, Sustainability compliant. Multi standards certified (IEC, CCC, EAC) and compliant with the railway European standard EN 45545 R22HL3.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003cbr\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of product\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eResistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-1\u003cbr\u003eAC-3\u003cbr\u003eAC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit: \u0026lt;= 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e9 A (at \u0026lt;60 Â°C) at \u0026lt;= 440 V AC AC-3 for power circuit\u003cbr\u003e25 A (at \u0026lt;60 Â°C) at \u0026lt;= 440 V AC AC-1 for power circuit\u003cbr\u003e9 A (at \u0026lt;60 Â°C) at \u0026lt;= 440 V AC AC-3e for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e2.2 kW at 220\/230 V AC 50 Hz (AC-3)\u003cbr\u003e4 kW at 380\/400 V AC 50 Hz (AC-3)\u003cbr\u003e4 kW at 415 V AC 50 Hz (AC-3)\u003cbr\u003e4 kW at 440 V AC 50 Hz (AC-3)\u003cbr\u003e5.5 kW at 500 V AC 50 Hz (AC-3)\u003cbr\u003e5.5 kW at 660\/690 V AC 50 Hz (AC-3)\u003cbr\u003e2.2 kW at 220\/230 V AC 50 Hz (AC-3e)\u003cbr\u003e4 kW at 380\/400 V AC 50 Hz (AC-3e)\u003cbr\u003e4 kW at 415 V AC 50 Hz (AC-3e)\u003cbr\u003e4 kW at 440 V AC 50 Hz (AC-3e)\u003cbr\u003e5.5 kW at 500 V AC 50 Hz (AC-3e)\u003cbr\u003e5.5 kW at 660\/690 V AC 50 Hz (AC-3e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective cover\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003etype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1\u003cbr\u003e type mirror contact 1 NC conforming to IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit: 690 V conforming to IEC 60947-4-1\u003cbr\u003eSignalling circuit: 690 V conforming to IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e10 A (at 60 Â°C) for signalling circuit\u003cbr\u003e25 A (at 60 Â°C) for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V for power circuit conforming to IEC 60947\u003cbr\u003e140 A AC for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e250 A DC for signalling circuit conforming to IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e10 A gG for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e25 A gG at \u0026lt;= 690 V coordination type 1 for power circuit\u003cbr\u003e20 A gG at \u0026lt;= 690 V coordination type 2 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime constant\u003c\/td\u003e\n\u003ctd\u003e37 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eDC low consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eWith integral suppression device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e0.1...0.25 Uc (-40â¦70 Â°C):drop-out DC\u003cbr\u003e0.7...1.25 Uc (-40â¦70 Â°C):operational DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e2.5 mOhm - Ith 25 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e1.56 W AC-1\u003cbr\u003e0.2 W AC-3\u003cbr\u003e0.2 W AC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-overlap time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms on de-energisation between NC and NO contact\u003cbr\u003e1.5 ms on energisation between NC and NO contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e77 Â±15 % ms closing\u003cbr\u003e25 Â±20 % ms opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in W\u003c\/td\u003e\n\u003ctd\u003e4 W (at 20 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in W\u003c\/td\u003e\n\u003ctd\u003e4 W at 20 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit: lugs-ring terminals - external diameter: 8 mm\u003cbr\u003ePower circuit: lugs-ring terminals - external diameter: 9.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ã 6 mm M3.5\u003cbr\u003eControl circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5\u003cbr\u003ePower circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5\u003cbr\u003ePower circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ã 6 mm M3.5\u003cbr\u003eControl circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5\u003cbr\u003ePower circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003eRail\u003cbr\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e0.6 Mcycles 25 A AC-1 at Ue \u0026lt;= 440 V\u003cbr\u003e2 Mcycles 9 A AC-3 at Ue \u0026lt;= 440 V\u003cbr\u003e2 Mcycles 9 A AC-3e at Ue \u0026lt;= 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e30 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load conforming to EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load conforming to EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e0...3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-4-1\u003cbr\u003eEN\/IEC 60947-5-1\u003cbr\u003eEN 45545: R22 HL3\u003cbr\u003eEN 45545: R26 HL3\u003cbr\u003eDIN 5510-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct certifications\u003c\/td\u003e\n\u003ctd\u003eIEC\u003cbr\u003eCCC\u003cbr\u003eEAC\u003cbr\u003eUA\u003cbr\u003eTR\u003cbr\u003eUKCA\u003cbr\u003eCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840588992734,"sku":"LC1D096FLS207-Sealed","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Never Used Surplus","offer_id":42651267236062,"sku":"LC1D096FLS207","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Used","offer_id":42651267268830,"sku":"LC1D096FLS207-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LC1D096FLS207.jpg?v=1649211292","url":"https:\/\/plc-direct.com\/en-se\/products\/lc1d096fls207","provider":"PLC Direct","version":"1.0","type":"link"}