{"product_id":"ladr0","title":"LADR0 Schneider Electric","description":"\u003cp\u003eTeSys Deca time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD. It provides 1NO+1NC contacts rated up to 10A 690V AC, Off-delay setting range 0.3-3s, connection by screw clamp terminals. LADR0 is a Schneider Electric time delay auxiliary contact block for TeSys Deca and TeSys F contactor. Clip-on front mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine). Add-on block with 1NO+1NC mechanically linked auxiliary contacts, with time delay operation. Off-delay setting range of 0.1-3s. High electrical durability , several millions of operating cycles in AC-14\/AC-15\/DC-13 according conditions. Mounting by clip-on on front of all TeSys Deca and TeSys F contactors.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003cbr\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eTime delay auxiliary contact block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange compatibility\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca CAD\u003cbr\u003eTeSys Deca LC1D\u003cbr\u003eTeSys F LC1F\u003cbr\u003eTeSys F CR1F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContacts operation\u003c\/td\u003e\n\u003ctd\u003eTime delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer type\u003c\/td\u003e\n\u003ctd\u003eOff delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime delay range\u003c\/td\u003e\n\u003ctd\u003e0.3...3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e6 A at 120 V AC-15\u003cbr\u003e1.04 A at 690 V AC-15\u003cbr\u003e0.55 A at 125 V DC-13\u003cbr\u003e0.1 A at 600 V DC-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e690 V IEC 60947-5-1\u003cbr\u003e600 V UL 60947-5-1\u003cbr\u003e600 V CSA C22.2 No 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e10 A (at 140 Â°F (60 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-5-1\u003cbr\u003eUL 60947-5-1\u003cbr\u003eCSA C22.2 No 60947-5-1\u003cbr\u003eGB\/T 14048.5\u003cbr\u003eEN 50012\u003cbr\u003eIEC 60335-1:Clause 30.2\u003cbr\u003eIEC 60335-2-40:Annex JJ\u003cbr\u003eUL 60335-2-40:Annex JJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eIECEE CB Scheme\u003cbr\u003eUL\u003cbr\u003eCSA\u003cbr\u003eCCC\u003cbr\u003eEAC\u003cbr\u003eUKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e140 A AC conforming to IEC 60947-5-1\u003cbr\u003e250 A DC conforming to IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible short-time rating\u003c\/td\u003e\n\u003ctd\u003e100 A 140 Â°F (60 Â°C) 1 s\u003cbr\u003e120 A 140 Â°F (60 Â°C) 500 ms\u003cbr\u003e140 A 140 Â°F (60 Â°C) 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd\u003eGG fuse 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e5 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-overlap time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms on de-energisation no overlap between NC and NO contact\u003cbr\u003e1.5 ms on energisation no overlap between NC and NO contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003escrew clamp terminals 1 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²)flexible with cable end\u003cbr\u003e screw clamp terminals 1 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²)flexible without cable end\u003cbr\u003e screw clamp terminals 2 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²)flexible with cable end\u003cbr\u003e screw clamp terminals 2 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²)flexible without cable end\u003cbr\u003e screw clamp terminals 1 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²)rigid\u003cbr\u003e screw clamp terminals 2 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²)rigid\u003cbr\u003e screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e15.05 lbf.in (1.7 N.m) flat Ã 6 mm\u003cbr\u003e 15.05 lbf.in (1.7 N.m) Philips No 2\u003cbr\u003e 15.05 lbf.in (1.7 N.m) pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e1.9 in (48 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.7 in (44 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e2.4 in (61 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecolor\u003c\/td\u003e\n\u003ctd\u003eDark grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840586600670,"sku":"LADR0-Sealed","price":923.0,"currency_code":"SEK","in_stock":true},{"title":"Never Used Surplus","offer_id":42651258912990,"sku":"LADR0","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Used","offer_id":42651258945758,"sku":"LADR0-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LADR0.jpg?v=1649211225","url":"https:\/\/plc-direct.com\/en-se\/products\/ladr0","provider":"PLC Direct","version":"1.0","type":"link"}