{"product_id":"c10f4","title":"C10F4 Schneider","description":"\u003cp\u003eThis is a 4 poles basic frame for ComPacT NSX100F. ComPacT NSX is designed to optimize space and breaking capacity for all standard and specific applications. This basic frame comes without trip unit, and is compatible with any type of trip unit which ordered separately. The breaking capacity Icu is 36kA at 415VAC 50\/60Hz. The operational voltage is 690VAC 50\/60Hz (limited to 440VAC 50\/60Hz if there is an earth-leakage protection). It can be equipped with a variety of optional functions and accessories. The dimensions are 140mm x 161mm x 86mm. It ensures compliance with international standards (IEC 60947), CCC, EAC and marine specifications. ComPacT NSX100F is part of Schneider Electric EcoStruxure Power architecture.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eBasic frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice application\u003c\/td\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral position\u003c\/td\u003e\n\u003ctd\u003eLeft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] rated current\u003c\/td\u003e\n\u003ctd\u003e100 A at 40 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] rated ultimate short-circuit breaking capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA at 600 V AC 50\/60 Hz conforming to UL 508\u003cbr\u003e25 kA at 480 V AC 50\/60 Hz conforming to UL 508\u003cbr\u003e85 kA at 240 V AC 50\/60 Hz conforming to UL 508\u003cbr\u003e22 kA Icu at 525 V AC 50\/60 Hz conforming to IEC 60947-2\u003cbr\u003e25 kA Icu at 500 V AC 50\/60 Hz conforming to IEC 60947-2\u003cbr\u003e35 kA Icu at 440 V AC 50\/60 Hz conforming to IEC 60947-2\u003cbr\u003e36 kA Icu at 380\/415 V AC 50\/60 Hz conforming to IEC 60947-2\u003cbr\u003e8 kA Icu at 660\/690 V AC 50\/60 Hz conforming to IEC 60947-2\u003cbr\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance level\u003c\/td\u003e\n\u003ctd\u003eF 36 kA 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econtrol type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ics] rated service short-circuit breaking capacity\u003c\/td\u003e\n\u003ctd\u003e11 kA at 525 V AC 50\/60 Hz conforming to IEC 60947-2\u003cbr\u003e35 kA at 440 V AC 50\/60 Hz conforming to IEC 60947-2\u003cbr\u003e36 kA at 380\/415 V AC 50\/60 Hz conforming to IEC 60947-2\u003cbr\u003e4 kA at 660\/690 V AC 50\/60 Hz conforming to IEC 60947-2\u003cbr\u003e85 kA at 220\/240 V AC 50\/60 Hz conforming to IEC 60947-2\u003cbr\u003e12.5 kA at 500 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e50000 cycles conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e10000 cycles 690 V AC 50\/60 Hz In conforming to IEC 60947-2\u003cbr\u003e20000 cycles 690 V AC 50\/60 Hz In\/2 conforming to IEC 60947-2\u003cbr\u003e30000 cycles 440 V AC 50\/60 Hz In conforming to IEC 60947-2\u003cbr\u003e50000 cycles 440 V AC 50\/60 Hz In\/2 conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003eBackplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpside connection\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDownside connection\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection pitch\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd\u003eWithout protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth (W)\u003c\/td\u003e\n\u003ctd\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight (H)\u003c\/td\u003e\n\u003ctd\u003e161 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth (D)\u003c\/td\u003e\n\u003ctd\u003e86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840459886814,"sku":"C10F4-Sealed","price":1752.0,"currency_code":"SEK","in_stock":true},{"title":"Never Used Surplus","offer_id":46487489872094,"sku":"C10F4","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Used","offer_id":46487489904862,"sku":"C10F4-Used","price":0.0,"currency_code":"SEK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_fe8bf4ad-a134-4204-bbb4-051eddad3cbc.png?v=1753948781","url":"https:\/\/plc-direct.com\/en-se\/products\/c10f4","provider":"PLC Direct","version":"1.0","type":"link"}