{"product_id":"bmx-p34-2010","title":"BMX-P34-2010 Schneider","description":"\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eModicon M340 automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eProcessor module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcept\u003c\/td\u003e\n\u003ctd\u003eModbus\u003cbr\u003eCANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of racks\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slots\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O processor capacity\u003c\/td\u003e\n\u003ctd\u003e1024 I\/O multi-rack configuration\u003cbr\u003e704 I\/O single-rack configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue I\/O processor capacity\u003c\/td\u003e\n\u003ctd\u003e256 I\/O multi-rack configuration\u003cbr\u003e66 I\/O single-rack configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of application specific channel\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eDiagnostic counters Modbus\u003cbr\u003eEvent counters Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl channels\u003c\/td\u003e\n\u003ctd\u003eProgrammable loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotion control\u003c\/td\u003e\n\u003ctd\u003eIndependent axis CANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated connection type\u003c\/td\u003e\n\u003ctd\u003eNon isolated serial link RJ45 character mode asynchronous in baseband, RS232C 2 twisted shielded pairs 0.3...19.2 kbit\/s full duplex\u003cbr\u003eNon isolated serial link RJ45 character mode asynchronous in baseband, RS485 1 twisted shielded pair 0.3...19.2 kbit\/s half duplex\u003cbr\u003eNon isolated serial link RJ45, master\/slave Modbus, RTU\/ASCII asynchronous in baseband, RS232C 1 twisted shielded pair 0.3...19.2 kbit\/s half duplex\u003cbr\u003eNon isolated serial link RJ45, master\/slave Modbus, RTU\/ASCII asynchronous in baseband, RS485 1 twisted shielded pair 0.3...19.2 kbit\/s half duplex\u003cbr\u003eUSB port 12 Mbit\/s\u003cbr\u003eCANopen master bus SUB-D 9 2 twisted shielded pairs 20 kbit\/s...1 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication module processor capacity\u003c\/td\u003e\n\u003ctd\u003e2 Ethernet communication module\u003cbr\u003e4 AS-Interface module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eembedded communication service\u003c\/td\u003e\n\u003ctd\u003eNetwork management (NMT) CANopen\u003cbr\u003eProcess Data Object (PDO) CANopen\u003cbr\u003eService Data Object (SDO) CANopen\u003cbr\u003eSpecial functions (SYNC, EMCY, TIME) CANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission rate\u003c\/td\u003e\n\u003ctd\u003e1 Mbit\/s 0.0000000000â¦65.6 ft (0â¦20 m) 0.0000000000â¦2.0 ft (0â¦0.6 m)\u003cbr\u003e125 kbit\/s 0.0000000000â¦1640.4 ft (0â¦500 m) 0.0000000000â¦32.8 ft (0â¦10 m)\u003cbr\u003e20 kbit\/s 0.0000000000â¦8202.10 ft (0â¦2500 m) 0.0000000000â¦984.3 ft (0â¦300 m)\u003cbr\u003e250 kbit\/s 0.0000000000â¦820.2 ft (0â¦250 m) 0.0000000000â¦32.8 ft (0â¦10 m)\u003cbr\u003e50 kbit\/s 0.0000000000â¦3280.8 ft (0â¦1000 m) 0.0000000000â¦393.7 ft (0â¦120 m)\u003cbr\u003e500 kbit\/s 0.0000000000â¦328.08 ft (0â¦100 m) 0.0000000000â¦32.8 ft (0â¦10 m)\u003cbr\u003e800 kbit\/s 0.0000000000â¦131.2 ft (0â¦40 m) 0.0000000000â¦19.7 ft (0â¦6 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus type\u003c\/td\u003e\n\u003ctd\u003eCANopen M20 DS 301 V4.02 devices linked by daisy-chaining or tap junctions CSMA\/CA\u003cbr\u003eCANopen M20 DS 303-2 devices linked by daisy-chaining or tap junctions CSMA\/CA\u003cbr\u003eCANopen M20 DS 405 devices linked by daisy-chaining or tap junctions CSMA\/CA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of server device(s)\u003c\/td\u003e\n\u003ctd\u003e63 CANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of devices per segment\u003c\/td\u003e\n\u003ctd\u003e0â¦32character mode)\u003cbr\u003e0â¦32Modbus)\u003cbr\u003e0â¦16 672.6 ft (205 m) CANopen)\u003cbr\u003e0â¦32 607.0 ft (185 m) CANopen)\u003cbr\u003e0â¦64 524.9 ft (160 m) CANopen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of devices\u003c\/td\u003e\n\u003ctd\u003e2 point-to-point character mode\u003cbr\u003e2 point-to-point Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus length\u003c\/td\u003e\n\u003ctd\u003e0.0000000000â¦32.8 ft (0â¦10 m) serial link non isolated character mode segment\u003cbr\u003e0.0000000000â¦32.8 ft (0â¦10 m) serial link non isolated Modbus segment\u003cbr\u003e0.0000000000â¦3280.8 ft (0â¦1000 m) serial link isolated character mode segment\u003cbr\u003e0.0000000000â¦3280.8 ft (0â¦1000 m) serial link isolated Modbus segment\u003cbr\u003e0.0000000000â¦49.2 ft (0â¦15 m) character mode point-to-point\u003cbr\u003e0.0000000000â¦49.2 ft (0â¦15 m) Modbus point-to-point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum tap links length\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;49.2 ft (15 m) serial link non isolated character mode segment\u003cbr\u003e \u0026lt;49.2 ft (15 m) serial link non isolated Modbus segment\u003cbr\u003e \u0026lt;131.2 ft (40 m) serial link isolated character mode segment\u003cbr\u003e \u0026lt;131.2 ft (40 m) serial link isolated Modbus segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of addresses\u003c\/td\u003e\n\u003ctd\u003e0â¦248 character mode\u003cbr\u003e0â¦248 Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequests\u003c\/td\u003e\n\u003ctd\u003e1 K data bytes per request character mode\u003cbr\u003e252 data bytes per RTU request Modbus\u003cbr\u003e504 data bytes per ASCII request Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl parameter\u003c\/td\u003e\n\u003ctd\u003eOne CRC on each frame (RTU) Modbus\u003cbr\u003eOne LRC on each frame (ASCII) character mode\u003cbr\u003eOne LRC on each frame (ASCII) Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory description\u003c\/td\u003e\n\u003ctd\u003eSupplied memory card (BMXRMS008MP) backup of programs, constants, symbols and data\u003cbr\u003eInternal RAM 4096 kB\u003cbr\u003eInternal RAM 256 kB data\u003cbr\u003eInternal RAM 3584 kB program constants and symbols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum size of object areas\u003c\/td\u003e\n\u003ctd\u003e256 kB unlocated internal data\u003cbr\u003e32634 %Mi located internal bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault size of object areas\u003c\/td\u003e\n\u003ctd\u003e1024 %MWi internal words located internal data\u003cbr\u003e256 %KWi constant words located internal data\u003cbr\u003e512 %Mi located internal bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication structure\u003c\/td\u003e\n\u003ctd\u003e1 cyclic\/periodic master task\u003cbr\u003eNo auxiliary task\u003cbr\u003e64 event tasks\u003cbr\u003e1 periodic fast task\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution time per instruction\u003c\/td\u003e\n\u003ctd\u003e0.12 Âµs Boolean\u003cbr\u003e0.17 Âµs double-length words\u003cbr\u003e0.25 Âµs single-length words\u003cbr\u003e1.16 Âµs floating points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of instructions per ms\u003c\/td\u003e\n\u003ctd\u003e6.4 Kinst\/ms 65 % Boolean + 35 % fixed arithmetic\u003cbr\u003e8.1 Kinst\/ms 100 % Boolean\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem overhead\u003c\/td\u003e\n\u003ctd\u003e0.13 ms fast task\u003cbr\u003e0.7 ms master task\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e90 mA 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003eInternal power supply via rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LED\u003c\/td\u003e\n\u003ctd\u003e1 LED (Green) integrated machine\/installation bus operational (CAN RUN)\u003cbr\u003e1 LED (Green) processor running (RUN)\u003cbr\u003e1 LED (Red) I\/O module fault (I\/O)\u003cbr\u003e1 LED (Red) integrated machine\/installation bus fault (CAN ERR)\u003cbr\u003e1 LED (Red) memory card fault (CARD ERR)\u003cbr\u003e1 LED (Red) processor or system fault (ERR)\u003cbr\u003e1 LED (Yellow) activity on Modbus (SER COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.46 lb(US) (0.21 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840422826206,"sku":"BMX-P34-2010-Sealed","price":13883.0,"currency_code":"SEK","in_stock":true},{"title":"Never Used Surplus","offer_id":35629908459674,"sku":"BMX-P34-2010","price":0.0,"currency_code":"SEK","in_stock":false},{"title":"Used","offer_id":42379277336798,"sku":"BMX-P34-2010-Used","price":3837.0,"currency_code":"SEK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/BMXP342010_c235c6f6-b4c4-4e4c-a6d1-2f9714da580e.jpg?v=1640714675","url":"https:\/\/plc-direct.com\/en-se\/products\/bmx-p34-2010","provider":"PLC Direct","version":"1.0","type":"link"}