Static Control
214 products
Showing 193 - 214 of 214 products

Specifications
Model |
SJ-Q252 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
2600 mm 102.36" *5 |
|||
Total length |
2480 mm 97.64" |
|||
No. ofelectrodes |
41 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2660 g 93.89 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-Q228 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
2360 mm 92.91" *5 |
|||
Total length |
2240 mm 88.19" |
|||
No. ofelectrodes |
37 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2440 g 86.13 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-Q204 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
2120 mm 83.46" *5 |
|||
Total length |
2000 mm 78.74" |
|||
No. ofelectrodes |
33 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2230 g 78.71 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-Q180 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
1880 mm 74.02" *5 |
|||
Total length |
1760 mm 69.29" |
|||
No. ofelectrodes |
29 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2010 g 70.95 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-Q156 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
1640 mm 64.57" *5 |
|||
Total length |
1520 mm 59.84" |
|||
No. ofelectrodes |
25 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1800 g 63.54 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-Q132 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
1400 mm 55.12" *5 |
|||
Total length |
1280 mm 50.39" |
|||
No. ofelectrodes |
21 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1580 g 55.77 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-Q108 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
1160 mm 45.67" *5 |
|||
Total length |
1040 mm 40.94" |
|||
No. ofelectrodes |
17 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1340 g 47.30 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-Q084 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
920 mm 36.22" *5 |
|||
Total length |
800 mm 31.50" |
|||
No. ofelectrodes |
13 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1120 g 39.53 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-Q060 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
680 mm 26.77" *5 |
|||
Total length |
560 mm 22.05" |
|||
No. ofelectrodes |
9 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
890 g 31.41 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-Q036 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
440 mm 17.32" *5 |
|||
Total length |
350 mm 13.78" |
|||
No. ofelectrodes |
5 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
690 g 24.35 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll








Specifications
Model |
OP-87056 |
|||
Type |
Sensor head cable |
|||
Applicable product |
IL,IG,GV-T Series head |
|||
Cable end |
M8 straight - e-con |
|||
Length |
2 m 6.56' |
|||
Material |
Cable: Polyvinyl chloride (PVC) |
|||
Note |
The cable is common to the transmitter and receiver sides, and can be used on either of them. |
|||
Weight |
Approx. 80 g |
|||
Scroll


Specifications
Model |
OP-88766 |
|||
Rating |
Input |
100 to 240 VAC (50/60 Hz) |
||
Output |
24 VDC, 2.7 A |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
20 to 80% RH (no condensation) |
|||
Weight |
Approx. 260 g 9.17 oz |
|||
Scroll

Specifications
Model |
SJ-FB01 |
|||
Ion balance measurement |
Measurement range |
±50 V |
||
Measurement accuracy |
±0.5 V *1 |
|||
Minimum display unit |
0.1 V |
|||
Sampling cycle |
0.1 s |
|||
Installation distance |
50 mm 1.97" or more from SJ-F700 |
|||
Temperature measurement |
Measurement range |
0 to +50°C 32 to 122°F |
||
Measurement accuracy |
±2°C ±3.6°F *2 |
|||
Minimum display unit |
0.1°C 32.18°F |
|||
Sampling cycle |
0.5 s |
|||
Humidity measurement |
Measurement range |
10 to 85% RH |
||
Measurement accuracy |
±5% RH *2 |
|||
Minimum display unit |
1% RH |
|||
Sampling cycle |
0.5 s |
|||
Environmental resistance |
Ambient temperature |
0 to +50°C 32 to +122°F |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Material |
Case: PBT |
|||
Weight |
Approx. 30 g 1.05 oz |
|||
*1 At ±15 V or less; ±10% (indicated) for other ranges | ||||
Scroll

Specifications
Model |
SJ-F700 |
|||
Voltage application method |
Variable DC |
|||
Applied voltage |
±8200 V max. |
|||
Ion balance control method |
Multi-I.C.C |
|||
Ion balance |
When using SJ-FB01: ±1 V *1 *2 |
|||
Static elimination time |
Approx. 0.5 s *3 *2 |
|||
Installation distance |
50 mm 1.97" or more |
|||
Maximum air volume |
4.8 m3/min 169.51 ft3/min |
|||
Ozone density |
0.005 ppm or less |
|||
Saved data |
Items |
Date/time, Ion level, Electrostatic charge level, Air flow, Unit status, |
||
Sampling cycle |
0.1 s |
|||
Data history |
Data saved every hour |
|||
Event log |
Saved events: Errors, Warnings, Charge level threshold exceeded, Ion balance threshold |
|||
Other functions |
Auto-clean, Sensor feedback |
|||
Input |
IN1 |
Static elimination stop input |
Bidirectional voltage input |
|
IN2 |
Clean input |
|||
IN3 |
Event trigger input |
|||
Output |
Photo MOS relay output, N.O./N.C. switchable, |
|||
Output |
Number of outputs |
3 (OUT1 to OUT3) |
||
Functions |
Assignable functions: Static elimination status, Ion level alarm, Condition alarm, Fan rotation |
|||
Ethernet |
Standard |
100BASE-TX |
||
Connector |
RJ-45 8-pin connector |
|||
Rating |
Power voltage |
24 VDC ±10% or dedicated AC adapter (OP-88766) |
||
Current consumption |
Normal (including input/output load): 1.6 A or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F (0 to +45°C 32 to +113°F when using OP-88767 or OP-88768) |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Material |
Case: PC / ABS *7, Front ventilation guard: SUS, Rear suction guard: SUS, Louvers: PC / ABS *7, |
|||
Weight |
Approx. 1.2 kg 2.65 lb |
|||
*1 At a distance of 300 mm 11.81" with minimum air flow, straight louvers, and relative humidity of 65% | ||||
Scroll