Static Control
214 products
Showing 169 - 192 of 214 products

Specifications
Model |
SJ-E108A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1140 mm 44.88"*3 |
|||
Total length |
1040 mm 40.94" |
|||
No. ofelectrodes |
17 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1270 g 44.80oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-E084L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
920 mm 36.22"*3 |
|||
Total length |
800 mm 31.50" |
|||
No. ofelectrodes |
13 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1070 g 37.74oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-E084H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
900 mm 35.43"*3 |
|||
Total length |
800 mm 31.50" |
|||
No. ofelectrodes |
25 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1100 g 38.80oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-E084A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
900 mm 35.43"*3 |
|||
Total length |
800 mm 31.50" |
|||
No. ofelectrodes |
13 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1070 g 37.74oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-E060L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
680 mm 26.77"*3 |
|||
Total length |
560 mm 22.05" |
|||
No. ofelectrodes |
9 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
850 g 29.98oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-E060H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
660 mm 25.98"*3 |
|||
Total length |
560 mm 22.05" |
|||
No. ofelectrodes |
17 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
870 g 30.69oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-E060A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
660 mm 25.98"*3 |
|||
Total length |
560 mm 22.05" |
|||
No. ofelectrodes |
9 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
850 g 29.98oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-E036L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
440 mm 17.32"*3 |
|||
Total length |
350 mm 13.78" |
|||
No. ofelectrodes |
5 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
670 g 23.63oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-E036H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
420 mm 16.54"*3 |
|||
Total length |
350 mm 13.78" |
|||
No. ofelectrodes |
9 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
680 g 23.99oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-E036A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
420 mm 16.54"*3 |
|||
Total length |
350 mm 13.78" |
|||
No. ofelectrodes |
5 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
670 g 23.63oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-Q01 |
|||
Power source |
4 AA size batteries |
|||
Operating temperature range |
0 to +40°C |
|||
Operating humidity range |
30-85% RH (no condensation) |
|||
Operating time |
12 hours (continuous operation)/1 year (in standby mode) |
|||
Operation range |
Within 4m in front |
|||
Remote controller response time |
During setting/batch acquisition: 1s or less |
|||
Scroll

Specifications
Model |
OP-89229 |
|||
Overview |
It converts NPN type I/O of the SJ-E/H/Q Series to PNP type. It cannot be used in conjunction with OP-87422. |
|||
Note |
PNP Conversion Box |
|||
Scroll

Specifications
Model |
OP-89052 |
|||
Overview |
Use when cleaning an electrode probe. |
|||
Note |
Electrode cleaning kit for SJ-Q Series |
|||
Scroll

Specifications
Model |
OP-89051 |
|||
Overview |
Tungsten electrode probe. |
|||
Note |
Tungsten electrode probe for SJ-Q (5 supplied) |
|||
Scroll

Specifications
Model |
OP-87525 |
|||
Applicable product |
SJ-E036 |
|||
Note |
This product is used to mount both sides of the SJ-E036 Series. The mounting dimensions are the same as those for the SJ-H/GL/G/V/R Series. Also, use this product when you want to perform angle adjustments (±90°). |
|||
Scroll

Specifications
Model |
OP-87422 |
|||
Power supply |
Power voltage |
24 to 36 V DC ± 10% |
||
Power consumption |
40 mA (at 24 V)/50 mA (at 36 V) |
|||
Environmental resistance |
Ambient temperature |
0 to 50°C |
||
Relative humidity |
30 to 80% RH (No condensation) |
|||
Weight |
60 g |
|||
Scroll


Specifications
Model |
OP-87416 |
|||
Applicable product |
SJ-E |
|||
Note |
This product is used to mount both sides of the SJ-E Series. The mounting dimensions are the same as those for the SJ-H/GL/G/V/R Series. Also, use this product when you want to perform angle adjustments (±90°). |
|||
Scroll

Specifications
Model |
OP-87415 |
|||
Applicable product |
SJ-E Series |
|||
Note |
Attaching this product to the SJ-E Series prevents bending. Attach this product at equal intervals. |
|||
Scroll

Specifications
Model |
OP-87414 |
|||
Applicable product |
SJ-E Series |
|||
Note |
This is used when mounting on both sides of the SJ-Ex Series. |
|||
Scroll

Specifications
Model |
SJ-Q300 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
3080 mm 121.26" *5 |
|||
Total length |
2960 mm 116.54" |
|||
No. ofelectrodes |
49 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
3090 g 109.07 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll