Static Control
214 products
Showing 121 - 144 of 214 products

Specifications
Model |
SJ-H156C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
1560 mm 61.42" *4 |
|||
No. ofelectrodes |
24 |
|||
Static elimination bar length |
1520 mm 59.84" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
1550 g 54.67 oz |
||
*1 Value measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-H156A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
1560 mm 61.42" *3 |
|||
No. ofelectrodes |
24 |
|||
Static elimination bar length |
1520 mm 59.84" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1550 g 54.67 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H156 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
1560 mm 61.42" *3 |
|||
No. ofelectrodes |
36 |
|||
Static elimination bar length |
1520 mm 59.84" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1600 g 56.44 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H132C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
1320 mm 51.97" *4 |
|||
No. ofelectrodes |
20 |
|||
Static elimination bar length |
1280 mm 50.39" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
1400 g 49.38 oz |
||
*1 Value measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-H132A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
1320 mm 51.97" *3 |
|||
No. ofelectrodes |
20 |
|||
Static elimination bar length |
1280 mm 50.39" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1400 g 49.38 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H132 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
1320 mm 51.97" *3 |
|||
No. ofelectrodes |
30 |
|||
Static elimination bar length |
1280 mm 50.39" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1450 g 51.15 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H108C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
1080 mm 42.52" *4 |
|||
No. ofelectrodes |
16 |
|||
Static elimination bar length |
1040 mm 40.94" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
1200 g 42.33 oz |
||
*1 Value measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-H108A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
1080 mm 42.52" *3 |
|||
No. ofelectrodes |
16 |
|||
Static elimination bar length |
1040 mm 40.94" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1200 g 42.33 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H108 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
1080 mm 42.52" *3 |
|||
No. ofelectrodes |
24 |
|||
Static elimination bar length |
1040 mm 40.94" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1250 g 44.09 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H084C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
840 mm 33.07" *4 |
|||
No. ofelectrodes |
12 |
|||
Static elimination bar length |
800 mm 31.50" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
980 g 34.57 oz |
||
*1 Value measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-H084A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
840 mm 33.07" *3 |
|||
No. ofelectrodes |
12 |
|||
Static elimination bar length |
800 mm 31.50" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
980 g 34.57 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H084 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
840 mm 33.07" *3 |
|||
No. ofelectrodes |
18 |
|||
Static elimination bar length |
800 mm 31.50" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1000 g 35.27 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H060C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
600 mm 23.62" *4 |
|||
No. ofelectrodes |
8 |
|||
Static elimination bar length |
560 mm 22.05" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
780 g 27.51 oz |
||
*1 Value measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-H060A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
600 mm 23.62" *3 |
|||
No. ofelectrodes |
8 |
|||
Static elimination bar length |
560 mm 22.05" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
780 g 27.51 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H060 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
600 mm 23.62" *3 |
|||
No. ofelectrodes |
12 |
|||
Static elimination bar length |
560 mm 22.05" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
800 g 28.22 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H036C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
360 mm 14.17" *4 |
|||
No. ofelectrodes |
4 |
|||
Static elimination bar length |
340 mm 13.39" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Controller |
150 g 5.29 oz |
||
Static elimination bar |
500 g 17.64 oz |
|||
*1 Value measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-H036A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
360 mm 14.17" *3 |
|||
No. ofelectrodes |
4 |
|||
Static elimination bar length |
340 mm 13.39" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Controller |
150 g 5.29 oz |
||
Static elimination bar |
500 g 17.64 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H036 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
360 mm 14.17" *3 |
|||
No. ofelectrodes |
6 |
|||
Static elimination bar length |
340 mm 13.39" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Controller |
150 g 5.29 oz |
||
Static elimination bar |
510 g 17.99 oz |
|||
*1 Measured under the following conditions. | ||||
Scroll



Specifications
Model |
OP-87526 |
|||
Applicable product |
SJ-E Series |
|||
Note |
This is used when there is a desire to carefully clean a single electrode probe. |
|||
Scroll

Specifications
Model |
OP-87424 |
|||
Applicable product |
SJ-E Series |
|||
Note |
This is used when there is a desire to clean multiple electrode probes at one time. |
|||
Scroll