Static Control
214 products
Showing 97 - 120 of 214 products

Specifications
Model |
OP-42218 |
|||
Type |
Replacement filters for the electrode cleaning kit |
|||
Number included |
10 |
|||
Scroll

Specifications
Model |
SJ-C5H |
|||
Type |
10 pin to 10 pin cable |
|||
Applicable product |
SJ-H036* |
|||
Length |
5 m 16.4' |
|||
Scroll

Specifications
Model |
SJ-C2H |
|||
Type |
10 pin to 10 pin cable |
|||
Applicable product |
SJ-H036* |
|||
Length |
2 m 6.6' |
|||
Scroll

Specifications
Model |
SJ-C10H |
|||
Type |
10 pin to 10 pin cable |
|||
Applicable product |
SJ-H036* |
|||
Length |
10 m 32.8' |
|||
Scroll

Specifications
Model |
OP-42212 |
|||
Overview |
Cable for connecting the SJ-H* Series units. Three types (2-, 5-, 10- m cables) are available. This cable connects to the Relay Box as well. (Cable color: Gray) |
|||
Length |
10 m 32.8' |
|||
Scroll

Specifications
Model |
OP-42211 |
|||
Overview |
Cable for connecting the SJ-H* Series units. Three types (2-, 5-, 10- m cables) are available. This cable connects to the Relay Box as well. (Cable color: Gray) |
|||
Length |
5 m 16.4' |
|||
Scroll

Specifications
Model |
OP-42210 |
|||
Overview |
Cable for connecting the SJ-H* Series units. Three types (2-, 5-, 10- m cables) are available. This cable connects to the Relay Box as well. (Cable color: Gray) |
|||
Length |
2 m 6.6' |
|||
Scroll

Specifications
Model |
OP-84293 |
|||
Type |
Tungsten electrode probes |
|||
Applicable product |
Made for SJ-HA |
|||
Number included |
4 |
|||
Material |
Tungsten |
|||
Scroll

Specifications
Model |
OP-84292 |
|||
Type |
Tungsten electrode probes/Tungsten accelerating electrode probes |
|||
Applicable product |
Made for SJ-H |
|||
Number included |
Tungsten electrode probes (four) |
|||
Material |
Tungsten |
|||
Scroll

Specifications
Model |
SJ-H300C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
3000 mm 118.11" *4 |
|||
No. ofelectrodes |
48 |
|||
Static elimination bar length |
2960 mm 116.54" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
3150 g 111.11 oz |
||
*1 Value measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-H300A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
3000 mm 118.11" *3 |
|||
No. ofelectrodes |
48 |
|||
Static elimination bar length |
2960 mm 116.54" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
3150 g 111.11 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H300 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
3000 mm 118.11" *3 |
|||
No. ofelectrodes |
72 |
|||
Static elimination bar length |
2960 mm 116.54" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
3250 g 114.64 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H252C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
2520 mm 99.21" *4 |
|||
No. ofelectrodes |
40 |
|||
Static elimination bar length |
2480 mm 97.64" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
2700 g 95.24 oz |
||
*1 Value measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-H252A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
2520 mm 99.21" *3 |
|||
No. ofelectrodes |
40 |
|||
Static elimination bar length |
2480 mm 97.64" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
2700 g 95.24 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H252 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
2520 mm 99.21" *3 |
|||
No. ofelectrodes |
60 |
|||
Static elimination bar length |
2480 mm 97.64" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
2800 g 98.77 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H228C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
2280 mm 89.76" *4 |
|||
No. ofelectrodes |
36 |
|||
Static elimination bar length |
2240 mm 88.19" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
2350 g 82.89 oz |
||
*1 Value measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-H228A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
2280 mm 89.76" *3 |
|||
No. ofelectrodes |
36 |
|||
Static elimination bar length |
2240 mm 88.19" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
2350 g 82.89 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H228 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
2280 mm 89.76" *3 |
|||
No. ofelectrodes |
54 |
|||
Static elimination bar length |
2240 mm 88.19" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
2400 g 84.66 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H204C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
2040 mm 80.31" *4 |
|||
No. ofelectrodes |
32 |
|||
Static elimination bar length |
2000 mm 78.74" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
2000 g 70.55 oz |
||
*1 Value measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-H204A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
2040 mm 80.31" *3 |
|||
No. ofelectrodes |
32 |
|||
Static elimination bar length |
2000 mm 78.74" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
2000 g 70.55 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H204 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
2040 mm 80.31" *3 |
|||
No. ofelectrodes |
48 |
|||
Static elimination bar length |
2000 mm 78.74" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
2100 g 74.08 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H180C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
1800 mm 70.87" *4 |
|||
No. ofelectrodes |
28 |
|||
Static elimination bar length |
1760 mm 69.29" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
1750 g 61.73 oz |
||
*1 Value measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-H180A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
1800 mm 70.87" *3 |
|||
No. ofelectrodes |
28 |
|||
Static elimination bar length |
1760 mm 69.29" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1750 g 61.73 oz |
||
*1 Measured under the following conditions. | ||||
Scroll

Specifications
Model |
SJ-H180 |
|||
Type |
H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
1800 mm 70.87" *3 |
|||
No. ofelectrodes |
42 |
|||
Static elimination bar length |
1760 mm 69.29" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1850 g 65.26 oz |
||
*1 Measured under the following conditions. | ||||
Scroll