Static Control
214 products
Showing 25 - 48 of 214 products

Specifications
Model |
OP-31784 |
|||
Overview |
Brackets to secure both sides of the SJ-B. |
|||
Applicable product |
SJ-B |
|||
Scroll

Specifications
Model |
SJ-C3 |
|||
Type |
Controller/high voltage source extension cable |
|||
Applicable product |
SJ-M100/200/300/400 or SJ-F100 |
|||
Length |
3 m 9.84' |
|||
Scroll

Specifications
Model |
OP-75351 |
|||
Overview |
CAB structure tungsten electrode probe. |
|||
Applicable product |
SJ-M020G |
|||
Material |
Tungsten |
|||
Scroll

Specifications
Model |
OP-51644 |
|||
Overview |
CAB structure tungsten electrode probe. |
|||
Applicable product |
SJ-M030G/M070G/SJ-G |
|||
Material |
Tungsten |
|||
Scroll

Specifications
Model |
OP-51607 |
|||
Overview |
Tungsten electrode unit. Cannot be used with the SJ-M020G. |
|||
Applicable product |
SJ-M010/020 |
|||
Material |
Tungsten |
|||
Scroll

Specifications
Model |
OP-42214 |
|||
Type |
Silicon electrode probe |
|||
Applicable product |
SJ-R/SJ-M030C/M070C |
|||
Material |
Silicon |
|||
Scroll


Specifications
Model |
SJ-M300 |
|||
Type |
Controller |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa max. |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
164 mm 6.46" (SJ-M030G,SJ-M030C) |
|||
Total length |
220 mm 8.66" (SJ-M030G,SJ-M030C) |
|||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
35 to 65%RH (no condensation) |
|||
Weight |
Approx. 300 g |
|||
*1 Measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-M201 |
|||
Type |
Controller Unit |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Static elimination time |
0.5 sec max. *1 |
|||
Ion balance |
±15 V or less *2 |
|||
Supply pressure range |
0.001 to 0.5 MPa *3 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open c ollector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH |
|||
Weight |
Approx. 300 g |
|||
*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30°C 68 to 86°F, relative humidity 40 to 60%) | ||||
Scroll

Specifications
Model |
SJ-M200 |
|||
Type |
Controller |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Static elimination time |
0.5 sec. max.*1 |
|||
Ion balance |
±15 V*2 |
|||
Supply pressure range |
0.001 to 0.5 MPa*3 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
35 to 65%RH (no condensation)*3 |
|||
Weight |
Approx. 300 g |
|||
*1 Operating distance: 50 mm 1.97", Air volume: 60 NL/min, | ||||
Scroll

Specifications
Model |
SJ-M071G |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2 MPa or less |
|||
Effective length |
324 mm 12.756"*2 |
|||
Total length |
380 mm 14.961"*3 |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge (3 NL/min) /1electrode | ||||
Scroll

Specifications
Model |
SJ-M071C |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2 MPa or less |
|||
Effective length |
324 mm 12.756"*2 |
|||
Total length |
380 mm 14.961"*3 |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge: None | ||||
Scroll

Specifications
Model |
SJ-M070G |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa max. |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
324 mm 12.76"*2 |
|||
Total length |
380 mm 14.96"*3 |
|||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
35 to 65%RH (no condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-M070C |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa max. |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
324 mm 12.76"*2 |
|||
Total length |
380 mm 14.96"*3 |
|||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
35 to 65%RH (no condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Measured under the following conditions: | ||||
Scroll

Specifications
Model |
SJ-M070 |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa or less |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
324 mm12.756" |
|||
Total length |
380 mm14.961" |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Please make an inquiry as to the measurement condition. | ||||
Scroll

Specifications
Model |
SJ-M031G |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2 MPa or less |
|||
Effective length |
164 mm 6.457"*2 |
|||
Total length |
220 mm 8.66"*3 |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 600 g |
|||
*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge (3 NL/min) /1electrode | ||||
Scroll

Specifications
Model |
SJ-M031C |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2 MPa or less |
|||
Effective length |
164 mm 6.457"*2 |
|||
Total length |
220 mm 8.66"*3 |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 600 g |
|||
*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge: None | ||||
Scroll