Switch XT2S, Icu (415V) 50kA, 160A Ekip LS / I electronic trip unit, in 63A 3-pole fixed with front terminals.
Switch XT2S, Icu (415V) 50kA, 160A Ekip LS / I electronic trip unit, In 25A 3-pole fixed with front terminals.
Switch XT2S, Icu (415V) 50kA, 160A Ekip LS / I electronic trip unit, In 10A 3-pole fixed with front terminals.
CIRCUIT BREAKER TMAX XT2V 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MA Iu 100 A I3=600...1400 A
CIRCUIT BREAKER TMAX XT2V 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MA Iu 20 A I3=120...280 A
CIRCUIT BREAKER TMAX XT2L 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MA Iu 100 A I3=600...1400 A
CIRCUIT BREAKER TMAX XT2L 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MA Iu 32 A I3=192...448 A
CIRCUIT BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MA Iu 100 A I3=600...1400 A
C.BREAKER TMAX XT2S 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 40 I3=200...400 A
Boxed automatic circuit breaker for XT2S motor protection - Icu breaking capacity (415V) = 50kA - 160A- MA Magnetic only protection release with adjustable threshold 80 Im = 480 ... 1120 3-pole with front terminals.
Boxed automatic circuit breaker for XT2S motor protection - Icu breaking capacity (415V) = 50kA - 160A- MA Magnetic only protection release with adjustable threshold 52 Im = 314 ... 728 3-pole with front terminals.
Boxed automatic circuit breaker for XT2S motor protection - Icu breaking capacity (415V) = 50kA - 160A- MA Magnetic only protection release with adjustable threshold 32 Im = 192 ... 448 3-pole with fixed terminals.
Boxed automatic circuit breaker for XT2S motor protection - Icu breaking capacity (415V) = 50kA - 160A- MF magnetic only protection release with fixed threshold 12.5 Im = 175 3-pole with fixed terminals.
XT2S 160 TMG 32-160 4p F F
CIRCUIT BREAKER TMAX XT2V 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LS/I R 25 A
CIRCUIT BREAKER TMAX XT2V 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LS/I R 10 A
CIRCUIT BREAKER TMAX XT2V 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-M-I R 100 A
CIRCUIT BREAKER TMAX XT2V 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-M-I R 20 A
CIRCUIT BREAKER TMAX XT2V 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LSI R 63 A
CIRCUIT BREAKER TMAX XT2V 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LS/I R 100 A
CIRCUIT BREAKER TMAX XT2L 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LSI R 10 A
CIRCUIT BREAKER TMAX XT2L 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LS/I R 160 A FULLY RATED NEUTRAL
CIRCUIT BREAKER TMAX XT2L 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LS/I R 63 A
CIRCUIT BREAKER TMAX XT2L 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LSI R 100 A