{"product_id":"tm221ce40t","title":"TM221CE40T Schneider Electric","description":"\u003cp\u003eThis TM221 controller is part of the Modicon M221 Logic controller range. It has 40 logic I\/O and it is supplied with 24V DC. It is supplied with removable screw terminal blocks for connecting the I\/O, a removable screw terminal block for connecting the power supply, a button cell backup battery BR2032 and a cable for connecting the analog inputs. M221 logic controllers have three types of integrated communication port, Ethernet, RS 232\/RS 485 serial link and USB mini-B programming port. It enables the control of simple machines. The capacity of M221 logic controllers can be enhanced with the Modicon TM3 expansion module offer.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] rated supply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input number\u003c\/td\u003e\n\u003ctd\u003e24, discrete input 4 fast input IEC 61131-2 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input number\u003c\/td\u003e\n\u003ctd\u003e2 0...10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output type\u003c\/td\u003e\n\u003ctd\u003eTransistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output number\u003c\/td\u003e\n\u003ctd\u003e16 transistor 2 fast output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output current\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O number\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of I\/O expansion module\u003c\/td\u003e\n\u003ctd\u003e7 (local I\/O-Architecture)\u003cbr\u003e14 (remote I\/O-Architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage limits\u003c\/td\u003e\n\u003ctd\u003e20.4â¦28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush current\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption in W\u003c\/td\u003e\n\u003ctd\u003e17 W 24 V with max number of I\/O expansion module)\u003cbr\u003e4.9 W 24 V without I\/O expansion module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply output current\u003c\/td\u003e\n\u003ctd\u003e0.52 A 5 V expansion bus\u003cbr\u003e0.3 A 24 V expansion bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input logic\u003c\/td\u003e\n\u003ctd\u003eSink or source (positive\/negative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input voltage type\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input resolution\u003c\/td\u003e\n\u003ctd\u003e10 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLSB value\u003c\/td\u003e\n\u003ctd\u003e10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion time\u003c\/td\u003e\n\u003ctd\u003e1 ms per channel + 1 controller cycle time analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted overload on inputs\u003c\/td\u003e\n\u003ctd\u003e+\/- 30 V DC 5 min maximum)analog input\u003cbr\u003e+\/- 13 V DC permanent)analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage state 1 guaranteed\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 15 V input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage state 0 guaranteed\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5 V input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input current\u003c\/td\u003e\n\u003ctd\u003e7 mA discrete input\u003cbr\u003e5 mA fast input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e3.4 kOhm discrete input\u003cbr\u003e100 kOhm analog input\u003cbr\u003e4.9 kOhm fast input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e35 Âµs turn-off, I2...I5 input\u003cbr\u003e5 Âµs turn-on, I0, I1, I6, I7 fast input\u003cbr\u003e35 Âµs turn-on, other terminals input\u003cbr\u003e5 Âµs turn-off, I0, I1, I6, I7 fast input\u003cbr\u003e100 Âµs turn-off, other terminals input\u003cbr\u003e5 Âµs turn-on, turn-off, Q0...Q1 output\u003cbr\u003e50 Âµs turn-on, turn-off, Q2...Q3 output\u003cbr\u003e300 Âµs turn-on, turn-off, other terminals output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable filtering time\u003c\/td\u003e\n\u003ctd\u003e0 ms input\u003cbr\u003e3 ms input\u003cbr\u003e12 ms input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic (source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current per output common\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e100 kHz fast output (PWM\/PLS mode) Q0...Q1\u003cbr\u003e5 kHz output Q2...Q3\u003cbr\u003e0.1 kHz output Q4...Q15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute accuracy error\u003c\/td\u003e\n\u003ctd\u003e+\/- 1 % of full scale analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum leakage current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA transistor output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage drop\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e20000000 cycles transistor output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum tungsten load\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;12 W output and fast output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd\u003eOverload and short-circuit protection 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset time\u003c\/td\u003e\n\u003ctd\u003e1 s automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory capacity\u003c\/td\u003e\n\u003ctd\u003e256 kB user application and data RAM 10000 instructions\u003cbr\u003e256 kB internal variables RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData backed up\u003c\/td\u003e\n\u003ctd\u003e256 kB built-in flash memory backup of application and data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData storage equipment\u003c\/td\u003e\n\u003ctd\u003e2 GB SD card optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eBR2032 or CR2032X lithium non-rechargeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup time\u003c\/td\u003e\n\u003ctd\u003e1 year 77 Â°F (25 Â°C) by interruption of power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution time for 1 KInstruction\u003c\/td\u003e\n\u003ctd\u003e0.3 ms event and periodic task\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution time per instruction\u003c\/td\u003e\n\u003ctd\u003e0.2 Âµs Boolean\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExct time for event task\u003c\/td\u003e\n\u003ctd\u003e60 Âµs response time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum size of object areas\u003c\/td\u003e\n\u003ctd\u003e512 %KW constant words\u003cbr\u003e255 %TM timers\u003cbr\u003e255 %C counters\u003cbr\u003e8000 %MW memory words\u003cbr\u003e512 %M memory bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRealtime clock\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock drift\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 30 s\/month 77 Â°F (25 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulation loop\u003c\/td\u003e\n\u003ctd\u003eAdjustable PID regulator up to 14 simultaneous loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning functions\u003c\/td\u003e\n\u003ctd\u003ePTO 2 pulse\/direction 100 kHz)\u003cbr\u003ePTO 1 CW\/CCW 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Available\u003c\/td\u003e\n\u003ctd\u003ePWM\u003cbr\u003ePLS\u003cbr\u003eFrequency generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounting input number\u003c\/td\u003e\n\u003ctd\u003e4 fast input (HSC mode) 100 kHz 32 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecounter function\u003c\/td\u003e\n\u003ctd\u003eA\/B\u003cbr\u003ePulse\/direction\u003cbr\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated connection type\u003c\/td\u003e\n\u003ctd\u003eUSB port mini B USB 2.0\u003cbr\u003eNon isolated serial link serial 1 RJ45 RS232\/RS485\u003cbr\u003eEthernet RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003eSerial)serial link supply 5 V, \u0026lt;200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission rate\u003c\/td\u003e\n\u003ctd\u003e1.2...115.2 kbit\/s (115.2 kbit\/s by default) 49.2 ft (15 m) RS485\u003cbr\u003e1.2...115.2 kbit\/s (115.2 kbit\/s by default) 9.8 ft (3 m) RS232\u003cbr\u003e480 Mbit\/s USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication port protocol\u003c\/td\u003e\n\u003ctd\u003eUSB port USB - SoMachine-Network\u003cbr\u003eNon isolated serial link Modbus master\/slave - RTU\/ASCII or SoMachine-Network\u003cbr\u003e Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Ethernet\u003c\/td\u003e\n\u003ctd\u003e10BASE-T\/100BASE-TX 1 328.08 ft (100 m) copper cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Service\u003c\/td\u003e\n\u003ctd\u003eModbus TCP slave device\u003cbr\u003eEthernet\/IP adapter\u003cbr\u003eModbus TCP server\u003cbr\u003eModbus TCP client\u003cbr\u003eDHCP client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003e1 LED (green) for PWR\u003cbr\u003e1 LED (green) for RUN\u003cbr\u003e1 LED (red) for module error (ERR)\u003cbr\u003e1 LED (green) for SD card access (SD)\u003cbr\u003e1 LED (red) for BAT\u003cbr\u003e1 LED per channel (green) for I\/O state\u003cbr\u003e1 LED (green) for SL\u003cbr\u003eEthernet network activity (green) for ACT\u003cbr\u003eEthernet network link (yellow) for Link (Link Status)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003eremovable screw terminal block for inputs\u003cbr\u003e removable screw terminal block for outputs\u003cbr\u003e terminal block, 3 for connecting the 24 V DC power supply\u003cbr\u003e connector, 4 for analogue inputs\u003cbr\u003eMini B USB 2.0 connector for a programming terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum cable distance between devices\u003c\/td\u003e\n\u003ctd\u003eShielded cable \u0026lt;32.8 ft (10 m) fast input\u003cbr\u003eUnshielded cable \u0026lt;98.4 ft (30 m) output\u003cbr\u003eUnshielded cable \u0026lt;98.4 ft (30 m) digital input\u003cbr\u003eUnshielded cable \u0026lt;3.3 ft (1 m) analog input\u003cbr\u003eShielded cable \u0026lt;9.8 ft (3 m) fast output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eBetween input and internal logic 500 V AC\u003cbr\u003eBetween fast input and internal logic 500 V AC\u003cbr\u003eNon-insulated between inputs\u003cbr\u003eBetween output and internal logic 500 V AC\u003cbr\u003eNon-insulated between analogue input and internal logic\u003cbr\u003eNon-insulated between analogue inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003eTop hat type TH35-15 rail IEC 60715\u003cbr\u003eTop hat type TH35-7.5 rail IEC 60715\u003cbr\u003e plate or panel with fixing kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e3.5 in (90 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e2.8 in (70 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e6.3 in (160 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e1.005 lb(US) (0.456 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840820039902,"sku":"TM221CE40T-Sealed","price":316.95,"currency_code":"EUR","in_stock":true},{"title":"Never Used Surplus","offer_id":42763138302174,"sku":"TM221CE40T","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Used","offer_id":42763138334942,"sku":"TM221CE40T-Used","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/TM221CE40T.jpg?v=1651530244","url":"https:\/\/plc-direct.com\/en-de\/products\/tm221ce40t","provider":"PLC Direct","version":"1.0","type":"link"}