{"product_id":"nr-pm01","title":"NR-PM01 Keyence","description":"\u003ch2 class=\"prd-utility-heading-3 prd-utility-marginBottom-7\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"prd-specsTable prd-utility-focusRing\" tabindex=\"0\" data-controller=\"horizontal-scroll-state scroll-to-coord\" data-action=\"resize@window-\u0026gt;horizontal-scroll-state#setOverflowing scroll-\u0026gt;horizontal-scroll-state#setScrolled\" data-horizontal-scroll-state-target=\"container\" data-horizontal-scroll-state-overflowing-class=\"is-overflowing\" data-horizontal-scroll-state-has-scrolled-class=\"is-hasScrolled\" data-scroll-to-coord-target=\"container\"\u003e\n\u003cdiv class=\"prd-utility-body-small\"\u003e\n\u003cdiv class=\"specTable-block\"\u003e\u003ctable class=\"specTable-stibo-3282397\"\u003e\u003ctbody\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"key_att_1001\" colspan=\"4\"\u003e\u003cp\u003eModel\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"key_att_1001\"\u003e\u003cp\u003eNR-PM01\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_24011\" rowspan=\"25\"\u003e\u003cp\u003ePerformance Specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24011\" rowspan=\"2\"\u003e\u003cp\u003eMeasurement specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24011\" colspan=\"2\"\u003e\u003cp\u003ePhase wire system\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24011\"\u003e\u003cp\u003e1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire (switchable)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24012\" colspan=\"2\"\u003e\u003cp\u003eNo. of measurement circuits\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24012\"\u003e\u003cp\u003e1\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24013\" colspan=\"3\"\u003e\u003cp\u003ePrimary side rated current (In)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24013\"\u003e\u003cp\u003eWith dedicated NR-CT250 CT: 250 A\u003cbr\u003eWith dedicated NR-CT600 CT: 600 A\u003cbr\u003eWith dedicated NR-CT050 CT: 50 A\u003cbr\u003eWith dedicated NR-CT100 CT: 100 A\u003cbr\u003eor general-purpose CT (secondary side rated input current 1 A)\u003csup\u003e*1\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24014\" colspan=\"3\"\u003e\u003cp\u003eOvercurrent withstand capability\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24014\"\u003e\u003cp\u003e1.2 times the primary side rated current (can be continuous), 10 times the primary side rated current (1 sec or less)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24015\" rowspan=\"4\"\u003e\u003cp\u003eRated input voltage (direct input)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24015\" colspan=\"2\"\u003e\u003cp\u003e1-phase 2-wire \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24015\"\u003e\u003cp\u003eWith dedicated NR-CT250\/CT600 CT: 100–277 V AC (L-N)\u003cbr\u003eWith dedicated NR-CT050\/CT100 CT: 100–240 V AC (L-N)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24016\" colspan=\"2\"\u003e\u003cp\u003e1-phase 3-wire\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24016\"\u003e\u003cp\u003e100–240 V AC (L-N), 200–480 V AC (L-L)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24017\" colspan=\"2\"\u003e\u003cp\u003e3-phase 3-wire\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24017\"\u003e\u003cp\u003eWith dedicated NR-CT250\/CT600 CT: 173–480 V AC (L-L)\u003cbr\u003eWith dedicated NR-CT050\/CT100 CT: 173–240 V AC (L-L)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24018\" colspan=\"2\"\u003e\u003cp\u003e3-phase 4-wire\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24018\"\u003e\u003cp\u003eWith dedicated NR-CT250\/CT600 CT: 100–277 V AC (L-N), 173–480 V AC (L-L)\u003cbr\u003eWith dedicated NR-CT050\/CT100 CT: 100–240 V AC (L-N), 173–415 V AC (L-L)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24019\" colspan=\"3\"\u003e\u003cp\u003eMaximum allowable earth voltage\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24019\"\u003e\u003cp\u003eWith dedicated NR-CT250\/CT600 CT: 480 V AC\u003cbr\u003eWith dedicated NR-CT050\/CT100 CT: 240 V AC\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24020\" colspan=\"3\"\u003e\u003cp\u003eInput voltage fluctuation range \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24020\"\u003e\u003cp\u003e−15% to +15% of rated input voltage\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24021\" colspan=\"3\"\u003e\u003cp\u003eRated input frequency\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24021\"\u003e\u003cp\u003e50\/60 Hz\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24022\" rowspan=\"6\"\u003e\u003cp\u003eMeasurement range\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24022\" colspan=\"2\"\u003e\u003cp\u003eVoltage\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24022\"\u003e\u003cp\u003eMeasurable range: Within rated input voltage\u003cbr\u003eDisplay resolution: 0.1 V\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24023\" colspan=\"2\"\u003e\u003cp\u003eCurrent\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24023\"\u003e\u003cp\u003eMeasurable range: Within primary side rated current\u003cbr\u003eDisplay resolution: 0.001 A\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24024\" colspan=\"2\"\u003e\u003cp\u003eActive energy\/Reactive energy\/Apparent energy (Instantaneous)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24024\"\u003e\u003cp\u003eMeasurable range: -8942.400 to +8942.400 [kW\/kvar\/kVA]\u003cbr\u003eDisplay resolution: 0.001 [kW\/kvar\/kVA]\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24025\" colspan=\"2\"\u003e\u003cp\u003eActive energy\/Reactive energy\/Apparent energy (Integrated)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24025\"\u003e\u003cp\u003eMeasurable range: 0.000 to 999999.999 [kWh\/kvarh\/kVah]\u003cbr\u003eDisplay resolution: 0.001 [kWh\/kvarh\/kVAh]\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24026\" colspan=\"2\"\u003e\u003cp\u003ePower factor (PF)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24026\"\u003e\u003cp\u003eMeasurable range: -1.00–1.00\u003cbr\u003eDisplay resolution: 0.01\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24027\" colspan=\"2\"\u003e\u003cp\u003eFrequency\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24027\"\u003e\u003cp\u003eMeasurable range: 0.0 to 90.0 Hz\u003cbr\u003eDisplay resolution: 0.1 Hz\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24028\" rowspan=\"8\"\u003e\u003cp\u003eMeasurement accuracy\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24028\" colspan=\"2\"\u003e\u003cp\u003eVoltage \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24028\"\u003e\u003cp\u003e±0.5% of rdg (within rated input voltage)\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24029\" colspan=\"2\"\u003e\u003cp\u003eCurrent\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24029\"\u003e\u003cp\u003eWith dedicated NR-CT250\/CT600 CT: ± 0.5% of rdg (5% ≤ In ≤ 120%) and ± 1.0% of rdg (1% ≤ In ≤ 5%)\u003cbr\u003eWith dedicated NR-CT050\/CT100 CT: ±0.5% of F.S.\u003cbr\u003e\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24030\" colspan=\"2\"\u003e\u003cp\u003eActive energy (power factor of 1)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24030\"\u003e\u003cp\u003e±1.0% of rdg (1% ≤ In ≤ 120%)\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24031\" colspan=\"2\"\u003e\u003cp\u003eReactive energy (reactive power factor of 1)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24031\"\u003e\u003cp\u003e±2.0% of rdg (5% ≤ In ≤ 120%)\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24032\" colspan=\"2\"\u003e\u003cp\u003eApparent energy\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24032\"\u003e\u003cp\u003eWith dedicated NR-CT250\/CT600 CT: ±1.0% of rdg (1% ≤ In ≤ 120%)\u003csup\u003e*3\u003c\/sup\u003e\u003cbr\u003eWith dedicated NR-CT050\/CT100 CT: ±1.0% of rdg (5% ≤ In ≤ 120%)\u003csup\u003e*3\u003c\/sup\u003e\u003cbr\u003e\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24033\" colspan=\"2\"\u003e\u003cp\u003eEffects of ambient temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24033\"\u003e\u003cp\u003e±0.03% of rdg\/°C\u003csup\u003e*4\u003c\/sup\u003e\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24034\" colspan=\"2\"\u003e\u003cp\u003ePower factor (PF) \u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24034\"\u003e\u003cp\u003e±0.01\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_24035\" colspan=\"2\"\u003e\u003cp\u003eFrequency\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24035\"\u003e\u003cp\u003e±0.1 [Hz]\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_24037\" rowspan=\"9\"\u003e\u003cp\u003eGeneral specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24037\" colspan=\"3\"\u003e\u003cp\u003ePower voltage\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24037\"\u003e\u003cp\u003e—(Powered by NR-PMC10)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24038\" colspan=\"3\"\u003e\u003cp\u003eOperating ambient temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24038\"\u003e\u003cp\u003e0 to 55°C \u003cspan class=\"prd-utility-color-inch\"\u003e32°F to 131°F\u003c\/span\u003e (no freezing)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24039\" colspan=\"3\"\u003e\u003cp\u003eOperating ambient humidity\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24039\"\u003e\u003cp\u003eMax. 85% RH (no condensation)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24040\" colspan=\"3\"\u003e\u003cp\u003eWithstand voltage\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24040\"\u003e\u003cp\u003e2500 V AC\/minute\u003cbr\u003e• Between all terminals and case\u003cbr\u003e• Between voltage measurement terminal and expansion port\u003cbr\u003e• Between CT input terminal and expansion port\u003cbr\u003e* With dedicated CT\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24041\" colspan=\"3\"\u003e\u003cp\u003eInsulation resistance\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24041\"\u003e\u003cp\u003e20 MΩ or more at 500 V DC\u003cbr\u003e• Between all terminals and case\u003cbr\u003e• Between voltage measurement terminal, all CT input terminals and expansion port\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24042\" colspan=\"3\"\u003e\u003cp\u003eVibration\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24042\"\u003e\u003cp\u003eFrequency: 10 to 500 Hz; Power spectral density: 0.033 G\u003csup\u003e2\u003c\/sup\u003e\/Hz for X, Y and Z directions\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24043\" colspan=\"3\"\u003e\u003cp\u003eMaterial\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24043\"\u003e\u003cp\u003ePolycarbonate\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24044\" colspan=\"3\"\u003e\u003cp\u003eCurrent consumption\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24044\"\u003e\u003cp\u003e36 mA or less\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_24045\" colspan=\"3\"\u003e\u003cp\u003eWeight\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_24045\"\u003e\u003cp\u003eApprox. 110 g \u003cspan class=\"prd-utility-color-inch\"\u003e3.88 oz\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-foot\"\u003e\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_24013; SPEC_SP_24028; SPEC_SP_24029; SPEC_SP_24030; SPEC_SP_24031; SPEC_SP_24032; SPEC_SP_24033; SPEC_SP_24034; SPEC_SP_24035\" colspan=\"5\" verticalalignment=\"0\"\u003e\u003cp\u003e\u003csup\u003e*1\u003c\/sup\u003e Primary side rated current: 1 to 2000 A, Secondary side rated input current: 1 A, Nominal cross-sectional area: 0.2 mm\u003csup\u003e2\u003c\/sup\u003e to 1.5 mm\u003csup\u003e2\u003c\/sup\u003e \u003cspan class=\"prd-utility-color-inch\"\u003e0.0003 in\u003csup\u003e2\u003c\/sup\u003e to 0.0023 in\u003csup\u003e2\u003c\/sup\u003e\u003c\/span\u003e. However, if a general-purpose CT is used, it does not meet the requirements of EU Directives or CSA certification.\u003cbr\u003e\u003csup\u003e*2\u003c\/sup\u003e Values when at room temperature and rated frequency. Does not include CT precision. Only the measurement resolution may be shifted at times.\u003cbr\u003e\u003csup\u003e*3\u003c\/sup\u003e This value to be used as a guideline when multiple Power Monitors are used to measure the total apparent energy.\u003cbr\u003e\u003csup\u003e*4\u003c\/sup\u003e Excluding temperature fluctuations due to measured current fluctuations.\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prd-specsTable-overlay prd-largeScreen-hidden\"\u003e\n\u003cdiv class=\"prd-specsTable-overlayInner\" aria-hidden=\"true\" data-action=\"click-\u0026gt;scroll-to-coord#run\" data-x-coord=\"100\"\u003e\n\u003cp class=\"prd-utility-marginBottom-2\"\u003e\n\u003csvg class=\"prd-specsTable-overlayIcon\" viewbox=\"0 0 30 30\" data-action=\"click-\u0026gt;series-header#doScroll\"\u003e\n\u003cuse xlink:href=\"#icon-horizontal-scrollable\"\u003e\u003c\/use\u003e\n\u003c\/svg\u003e\n\u003c\/p\u003e\n\u003cp class=\"prd-specsTable-overlayLabel prd-utility-body-extraSmall prd-utility-marginBottom-0\"\u003eScroll\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Keyence","offers":[{"title":"Sealed Surplus","offer_id":47827916488926,"sku":"NR-PM01-Sealed","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Never Used Surplus","offer_id":47827916521694,"sku":"NR-PM01","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Used","offer_id":47827916554462,"sku":"NR-PM01-Used","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_keyence_stock_fc275dbd-8c6d-4835-bab9-46a6e5d656a7.png?v=1768393415","url":"https:\/\/plc-direct.com\/en-de\/products\/nr-pm01","provider":"PLC Direct","version":"1.0","type":"link"}