{"product_id":"metseion93040","title":"METSEION93040 Schneider","description":"\u003cp\u003eThe PowerLogic ION9000 is your 24\/7 power quality expert, providing information, not just data. A comprehensive, industry-leading Power Quality Instrument (PQI-A) certified to IEC 62586-1\/-2 ensures reliable, precision performance that is perfect for both supply and demand side applications. Third-party lab verified accuracy to Class 0.1S (ANSI C12.20, IEC 62053-22). Highly customizable and modular, ION technology programmability and field installable option modules can satisfy any solution, protecting your investment now and into the future. Providing power quality analysis according to both EN 50160 and IEEE 519, and patented Disturbance Direction Detection, you become a PQ expert and will be able to respond rapidly to system events. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol, ability to enable\/disable communication ports, and 50 user configurable accounts. With 2 GB of memory to support 50 data logs, 50+ user-definable alarms, disturbance and transient waveforms. 1\/2 cycle RMS logging, custom web pages, min\/max logs, energy trends, and Time of Use. The ability to timestamp events to +\/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 8 digital inputs, 4 digital outputs and 2 relay outputs, plus the ability to add up to 4 option modules. Option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Ability to capture power quality events as short as 20 Âµs and record both waveforms and 1\/2-cycle RMS concurrently on any event. Voltage inputs of 100 to 690 V between phases; Current inputs with low voltage transducer; Frequency of 20-450 Hz. Wide control power range of 90 to 480 VAC or 110 to 480 VDC. DIN rail mounting with remote display and panel mounting (with back to back adapter), plus 2 display options, further enhance the flexibility and adaptability of the ION9000.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eEnergy and power quality meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eION93040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003ePowerLogic ION9000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003ePower monitoring\u003cbr\u003eWAGES metering\u003cbr\u003eNet metering\u003cbr\u003eMedium voltage\u003cbr\u003eHigh voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering type\u003c\/td\u003e\n\u003ctd\u003eDemand current I1, I2, I3, I4, I5\u003cbr\u003ePeak demand currents\u003cbr\u003eDemand power P, Q, S\u003cbr\u003ePeak demand power PM, QM, SM\u003cbr\u003eCalculated active and reactive energy (+\/- W.h, +\/- VAR.h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProvided Equipment\u003c\/td\u003e\n\u003ctd\u003eRemote display\u003cbr\u003eRemote display adapter\u003cbr\u003eMounting instructions\u003cbr\u003eMounting Hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower quality analysis\u003c\/td\u003e\n\u003ctd\u003eEN 50160 compliance checking\u003cbr\u003eIEEE 519 harmonic limit\u003cbr\u003eIEC 61000-4-30 class A compliance reporting\u003cbr\u003eIEEE 519 compliance reporting\u003cbr\u003e waveform capture\u003cbr\u003e total demand distortion\u003cbr\u003e total harmonic distortion\u003cbr\u003e up to the 63rd harmonic\u003cbr\u003e up to the 127th harmonic with software\u003cbr\u003e disturbance direction detection\u003cbr\u003e dip, swell and transient\u003cbr\u003e half cycle data acquisition\u003cbr\u003e transient detection (20 Âµs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of measurement\u003c\/td\u003e\n\u003ctd\u003eVoltage sags and swells\u003cbr\u003eCurrent sags and swells\u003cbr\u003eVoltage\u003cbr\u003eCurrent\u003cbr\u003eFrequency\u003cbr\u003eActive and reactive power total\u003cbr\u003eApparent power total\u003cbr\u003eActive and reactive power per phase\u003cbr\u003eApparent power per phase\u003cbr\u003ePower factor total\u003cbr\u003ePower factor per phase\u003cbr\u003eActive and reactive energy\u003cbr\u003eApparent energy\u003cbr\u003eHarmonic distorsion (I THD \u0026amp; U THD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] rated supply voltage\u003c\/td\u003e\n\u003ctd\u003e90...480 V AC 45...66 Hz +\/- 10 %\u003cbr\u003e90...120 V AC 400 Hz +\/- 10 %\u003cbr\u003e110...480 V DC +\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003cbr\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRide-through time\u003c\/td\u003e\n\u003ctd\u003e100 ms 6 cycles at 60 Hz 120 V AC typical\u003cbr\u003e400 ms 24 cycles at 60 Hz 240 V AC typical\u003cbr\u003e1200 ms 72 cycles at 60 Hz 480 V AC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003etype of network\u003c\/td\u003e\n\u003ctd\u003e3P + N + E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption in VA\u003c\/td\u003e\n\u003ctd\u003e38 VA 480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e80 VA 480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e800 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eRemote LCD display\u003cbr\u003eColour touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling rate\u003c\/td\u003e\n\u003ctd\u003e1024 samples\/cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einput type\u003c\/td\u003e\n\u003ctd\u003eVoltage (impedance 5 MOhm)\u003cbr\u003eSplit core current transducer (impedance 200 kOhm)5 x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement voltage\u003c\/td\u003e\n\u003ctd\u003e57â¦400 V AC 42...69 Hz between phase and neutral\u003cbr\u003e100â¦690 V AC 42...69 Hz between phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement range\u003c\/td\u003e\n\u003ctd\u003e20â¦450 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd\u003e8 digital 30 V AC\/60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003eVoltage +\/- 0.1 %\u003cbr\u003eCurrent +\/- 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy class\u003c\/td\u003e\n\u003ctd\u003eClass 0.1S active energy IEC 62053-22\u003cbr\u003eClass 0.1 active energy IEC 61557-12\u003cbr\u003eClass 0.1 active energy ANSI C12.20\u003cbr\u003eClass 0.5S reactive energy IEC 62053-24\u003cbr\u003eClass 0.1 current IEC 61557-12\u003cbr\u003eClass 0.1 voltage IEC 61557-12\u003cbr\u003eClass 0.1 active power IEC 61557-12\u003cbr\u003eClass 0.5 power factor IEC 61557-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e4 digital\u003cbr\u003e2 form C relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication port protocol\u003c\/td\u003e\n\u003ctd\u003eModbus RTU 2400...115200 bps - 2-wire\u003cbr\u003eION 2400...115200 bps - 2-wire\u003cbr\u003eDNP3 2400...115200 bps - 2-wire\u003cbr\u003eModbus TCP 10\/100 Mbit\/s\u003cbr\u003eION TCP 10\/100 Mbit\/s\u003cbr\u003eDNP3 TCP 10\/100 Mbit\/s\u003cbr\u003eIEC 61850\u003cbr\u003eEthernet Modbus TCP\/IP daisy chain 10\/100 Mbit\/s\u003cbr\u003eDHCP\u003cbr\u003eDNS\u003cbr\u003eDLMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication port support\u003c\/td\u003e\n\u003ctd\u003e2 RS485 removable screw terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Ethernet\u003c\/td\u003e\n\u003ctd\u003e10\/100BASE-TX 2 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication gateway\u003c\/td\u003e\n\u003ctd\u003eEthernet\/serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime synchronisation protocol\u003c\/td\u003e\n\u003ctd\u003eGPS\u003cbr\u003eIRIG-B\u003cbr\u003eNTP\u003cbr\u003eSNTP\u003cbr\u003ePTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData recording\u003c\/td\u003e\n\u003ctd\u003eTime stamping\u003cbr\u003eMin\/max of instantaneous values\u003cbr\u003eUser-definable data logs\u003cbr\u003eContinuous logging or snapshot\u003cbr\u003eTrending\/forecasting\u003cbr\u003eEvent logs\u003cbr\u003eAlarm logs\u003cbr\u003eConfiguration change\u003cbr\u003ePower outage\u003cbr\u003eUser login\/logout\u003cbr\u003eData logs\u003cbr\u003eGPS synchronisation\u003cbr\u003eSequence of event recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory capacity\u003c\/td\u003e\n\u003ctd\u003e2 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCybersecurity\u003c\/td\u003e\n\u003ctd\u003eSyslog protocol support\u003cbr\u003eRobust security logs\u003cbr\u003ePort hardening\u003cbr\u003eEnable\/disable communication ports\u003cbr\u003eHardware metrology lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb services\u003c\/td\u003e\n\u003ctd\u003eViewing of captured waveform\u003cbr\u003eWeb page\u003cbr\u003ePass\/fail report for IEEE 519\u003cbr\u003ePass\/fail report for EN 50160\u003cbr\u003eITIC (CBEMA) curve\u003cbr\u003eSEMI curve\u003cbr\u003eNEMA motor derating curve\u003cbr\u003eAlarm notification by e-mail\u003cbr\u003eTLS 1.2\u003cbr\u003ePush historical data via mail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet service\u003c\/td\u003e\n\u003ctd\u003eDHCP client\u003cbr\u003eDevice Profile Web Services (DPWS)\u003cbr\u003eRapid Scanning Tree Protocol (RSTP)\u003cbr\u003eFTP\/HTTP\/HTTPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Service\u003c\/td\u003e\n\u003ctd\u003eCompliant reports\u003cbr\u003ePower quality summary\u003cbr\u003eEnergy report\u003cbr\u003eEcoStruxure Power Events Analysis\u003cbr\u003eSMTP e-mail notification\u003cbr\u003eSNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTamperproof of settings\u003c\/td\u003e\n\u003ctd\u003eProtected by sealable cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003eDIN rail meter device\u003cbr\u003eDoor cut-out remote display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical insulation class\u003c\/td\u003e\n\u003ctd\u003eClass III EN\/IEC 62052-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation voltage\u003c\/td\u003e\n\u003ctd\u003eIII400â¦690 V conforming to EN 61010-1:ed. 3\u003cbr\u003eIII347â¦600 V conforming to UL 61010-1:ed. 3\u003cbr\u003eIII347â¦600 V conforming to CSA C22.2 No 61010-1:ed. 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e6.3 in (160 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e5.3 in (135.3 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e6.3 in (160 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e3.3 lb(US) (1.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarket Segment\u003c\/td\u003e\n\u003ctd\u003eData center\u003cbr\u003eHealthcare\u003cbr\u003eSemiconductor\u003cbr\u003ePharmaceutical\u003cbr\u003eChemical\u003cbr\u003eEnergy\u003cbr\u003eMining\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840765087966,"sku":"METSEION93040-Sealed","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Never Used Surplus","offer_id":46487530569950,"sku":"METSEION93040","price":17826.95,"currency_code":"EUR","in_stock":true},{"title":"Used","offer_id":46487530602718,"sku":"METSEION93040-Used","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_b4378da9-e807-4862-a9ff-4f071fec9e25.png?v=1753948996","url":"https:\/\/plc-direct.com\/en-de\/products\/metseion93040","provider":"PLC Direct","version":"1.0","type":"link"}