{"product_id":"lv481002","title":"LV481002 Schneider Electric","description":"\u003cp\u003eVigiPacT RHU is a front panel mounting communicating residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. It can activate an alarm and a pre-alarm. The operational supply voltage is 110\/130VAC 50\/60Hz. It is a type A earth-leakage protection class. The current sensitivity is from 30mA to 30A. The time delay is adjustable from 0 to 4.5s. It is installed on a front panel switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor. It complies with IEC 60755, IEC 60947-2 annex M and IEC 60947-5-1 standards. RUH is integrated in the Smart Panel architecture with the Modbus communication.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eVigiPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eRHU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eResidual current protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay application\u003c\/td\u003e\n\u003ctd\u003eMonitoring relay\u003cbr\u003eProtection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003eFront panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage protection class\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of setting\u003c\/td\u003e\n\u003ctd\u003eKeypad\u003cbr\u003eModbus address\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual earth-leakage sensitity adjustment type\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage sensitivity\u003c\/td\u003e\n\u003ctd\u003e0.03â¦1 A, adjustable in step of 0.001 A\u003cbr\u003e1â¦30 A, adjustable in step of 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage time delay\u003c\/td\u003e\n\u003ctd\u003eInstantaneous for 0.03 A\u003cbr\u003eAdjustable 0â¦4.5 s for 0.03â¦30 A adjustable in step of 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThreshold setting\u003c\/td\u003e\n\u003ctd\u003e0.015...1 A adjustable in step of 0.001 A pre-alarm\u003cbr\u003e1...30 A adjustable in step of 0.1 A pre-alarm\u003cbr\u003e0.03...1 A adjustable in step of 0.001 A alarm\u003cbr\u003e1...30 A adjustable in step of 0.1 A alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent sensors compatibility\u003c\/td\u003e\n\u003ctd\u003eVigiPacT TOA earth leakage current sensor\u003cbr\u003eVigiPacT A earth leakage current sensor\u003cbr\u003eVigiPacT L earth leakage current sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ithe] conventional enclosed thermal current\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum load\u003c\/td\u003e\n\u003ctd\u003e10 mA at 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] rated supply voltage\u003c\/td\u003e\n\u003ctd\u003e110...130 V AC 50\/60 Hz 70...110 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption in VA\u003c\/td\u003e\n\u003ctd\u003e8 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitored distribution system\u003c\/td\u003e\n\u003ctd\u003e1000 V - AC at 50\/60 Hz (maximum) \u003cbr\u003e1000 V - AC at 400 Hz (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarthing system\u003c\/td\u003e\n\u003ctd\u003eTT\u003cbr\u003eIT\u003cbr\u003eTN-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset\u003c\/td\u003e\n\u003ctd\u003eRemote reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest function\u003c\/td\u003e\n\u003ctd\u003eRemote test\u003cbr\u003eRemote test (via communication)\u003cbr\u003eLocal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal contacts composition\u003c\/td\u003e\n\u003ctd\u003e1 C\/O alarm fail-safe\u003cbr\u003e1 NO pre-alarm fail-safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of measurement\u003c\/td\u003e\n\u003ctd\u003eEarth fault current internal measurement, range: 20...200 %, accuracy: +\/- 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefresh time\u003c\/td\u003e\n\u003ctd\u003e0.5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication service\u003c\/td\u003e\n\u003ctd\u003eModbus slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTamperproof of settings\u003c\/td\u003e\n\u003ctd\u003eProtected by access code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eAlarm circuit: terminal block cable(s) 0.2â¦2.5 mmÂ² flexible AWG 22...AWG 12\u003cbr\u003eAlarm circuit: terminal block cable(s) 0.2â¦2.5 mmÂ² rigid AWG 22...AWG 12\u003cbr\u003eRelay test and fault reset: terminal block cable(s) 0.2â¦2.5 mmÂ² flexible AWG 22...AWG 12\u003cbr\u003eRelay test and fault reset: terminal block cable(s) 0.2â¦2.5 mmÂ² rigid AWG 22...AWG 12\u003cbr\u003eSensor: terminal block cable(s) 0.2â¦2.5 mmÂ² flexible AWG 22...AWG 12\u003cbr\u003eSensor: terminal block cable(s) 0.2â¦2.5 mmÂ² rigid AWG 22...AWG 12\u003cbr\u003eVoltage presence: terminal block cable(s) 0.2â¦2.5 mmÂ² flexible AWG 22...AWG 12\u003cbr\u003eVoltage presence: terminal block cable(s) 0.2â¦2.5 mmÂ² rigid AWG 22...AWG 12\u003cbr\u003ePower supply: terminal block cable(s) 0.2â¦2.5 mmÂ² flexible AWG 22...AWG 12\u003cbr\u003ePower supply: terminal block cable(s) 0.2â¦2.5 mmÂ² rigid AWG 22...AWG 12\u003cbr\u003ePre alarm: terminal block cable(s) 0.2â¦2.5 mmÂ² flexible AWG 22...AWG 12\u003cbr\u003ePre alarm: terminal block cable(s) 0.2â¦2.5 mmÂ² rigid AWG 22...AWG 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire stripping length\u003c\/td\u003e\n\u003ctd\u003eAlarm circuit: 6 mm\u003cbr\u003eRelay test and fault reset: 6 mm\u003cbr\u003eSensor: 6 mm\u003cbr\u003eVoltage presence: 6 mm\u003cbr\u003ePower supply: 6 mm\u003cbr\u003ePre alarm: 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eAlarm circuit: 0.5 N.m\u003cbr\u003eRelay test and fault reset: 0.5 N.m\u003cbr\u003eSensor: 0.5 N.m\u003cbr\u003eVoltage presence: 0.5 N.m\u003cbr\u003ePower supply: 0.5 N.m\u003cbr\u003ePre alarm: 0.5 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-2 Annex M\u003cbr\u003eEN\/IEC 60755\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e72 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e72 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e117 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCut-out dimensions\u003c\/td\u003e\n\u003ctd\u003e68 x 68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 front face: conforming to IEC 60529\u003cbr\u003eIP30 other parts: conforming to IEC 60529\u003cbr\u003eIP20 connection: conforming to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIK07 conforming to EN 50102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical robustness\u003c\/td\u003e\n\u003ctd\u003eVibrations 13.2...100 Hz: 0.7 g\u003cbr\u003eVibrations 2...13.2 Hz: +\/- 1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840717770974,"sku":"LV481002-Sealed","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Never Used Surplus","offer_id":42733277774046,"sku":"LV481002","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Used","offer_id":42733277806814,"sku":"LV481002-Used","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LV481002.jpg?v=1650833682","url":"https:\/\/plc-direct.com\/en-de\/products\/lv481002","provider":"PLC Direct","version":"1.0","type":"link"}