{"product_id":"lv431515","title":"LV431515 Schneider Electric","description":"\u003cp\u003eThis Micrologic 6.2 A (Ammeter) is a 4 poles 4d electronic trip unit used on Compact NSX 250 circuit breakers. This 250A rating electronic trip unit is an excellent choice for all standard and specific applications protection. It embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. It has an additional and adjustable ground fault protection. Micrologic 6.2 A indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. Micrologic 6.2 A is equipped with a display module that gives current measurement and allows fine adjustment settings. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eComPact NSX100...250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit name\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 6.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit technology\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Compatibility\u003c\/td\u003e\n\u003ctd\u003eComPact NSX250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of poles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtected poles description\u003c\/td\u003e\n\u003ctd\u003e3t + OSN\u003cbr\u003e3t + N\/2\u003cbr\u003e4t\u003cbr\u003e3t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral position\u003c\/td\u003e\n\u003ctd\u003eLeft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd\u003eL : for overload protection (long time)\u003cbr\u003eS : for short time short-circuit protection\u003cbr\u003eI : for instantaneous short-circuit protection\u003cbr\u003eG : for ground fault protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit rated current\u003c\/td\u003e\n\u003ctd\u003e250 A 104 Â°F (40 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-time pick-up adjustment type Ir (thermal protection)\u003c\/td\u003e\n\u003ctd\u003eAdjustable 9 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ir] long-time protection pick-up adjustment range\u003c\/td\u003e\n\u003ctd\u003e100...250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-time protection delay adjustment type tr\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[tr] long-time protection delay adjustment range\u003c\/td\u003e\n\u003ctd\u003e15â¦400 s 1.5 x Ir\u003cbr\u003e0.35â¦11 s 7.2 x Ir\u003cbr\u003e0.5â¦16 s 6 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal memory\u003c\/td\u003e\n\u003ctd\u003e20 minutes before and after tripping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-time protection pick-up adjustment type Isd\u003c\/td\u003e\n\u003ctd\u003eAdjustable 9 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Isd] Short-time protection pick-up adjustment range\u003c\/td\u003e\n\u003ctd\u003e1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-time protection delay adjustment type tsd\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[tsd] Short-time protection delay adjustment range\u003c\/td\u003e\n\u003ctd\u003e0â¦0.4 s IÂ²t=off\u003cbr\u003e0.1â¦0.4 s IÂ²t=on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstantaneous protection pick-up adjustment type Ii\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ii] instantaneous protection pick-up adjustment range\u003c\/td\u003e\n\u003ctd\u003e1.5...12 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround-fault protection pick-up adjustment type Ig\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ig] ground-fault protection pick-up adjustment range\u003c\/td\u003e\n\u003ctd\u003e0.4...1 x In In = 40 A\u003cbr\u003e0.2...1 x In In \u0026gt; 40 A\u003cbr\u003eIg enable on\/off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround-fault protection time delay adjustment type tg\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[tg] ground-fault protection time delay adjustment range\u003c\/td\u003e\n\u003ctd\u003e0â¦0.4 s IÂ²t=off\u003cbr\u003e0.1â¦0.4 s IÂ²t=on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage protection\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral protection settings\u003c\/td\u003e\n\u003ctd\u003e0.5 x Ir 3t + N\/2)\u003cbr\u003e1 x Ir 4t)\u003cbr\u003e1.6 x Ir 3t + OSN)\u003cbr\u003eNo protection 3t)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZone selective interlocking ZSI\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003eFlashing LED (green) for ready to operate\u003cbr\u003eLED 105 % Ir (red) for overload\u003cbr\u003eLED 90 % Ir (orange) for overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Measurement\u003c\/td\u003e\n\u003ctd\u003eAmmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication of data\u003c\/td\u003e\n\u003ctd\u003eMaintenance indicators\u003cbr\u003eMaximeters\/minimeters\u003cbr\u003eInstantaneous and demand values\u003cbr\u003eEnergy metering\u003cbr\u003ePower quality\u003cbr\u003eTime-stamped histories and event tables\u003cbr\u003eDemand current and power\u003cbr\u003eProtection and alarm settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical data recording\u003c\/td\u003e\n\u003ctd\u003eMaintenance indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840689885406,"sku":"LV431515-Sealed","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Never Used Surplus","offer_id":42717812195550,"sku":"LV431515","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Used","offer_id":42717812228318,"sku":"LV431515-Used","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LV431515.jpg?v=1650513674","url":"https:\/\/plc-direct.com\/en-de\/products\/lv431515","provider":"PLC Direct","version":"1.0","type":"link"}