{"product_id":"lucd18fu","title":"LUCD18FU Schneider Electric","description":"\u003cp\u003eTeSys U control and diagnostic unit to be inserted in advanced power bases LUB320, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 7.5kW@400V. It provides full protection to motors with a rated current Ir 4.5-18A (Ir adjustable), overload tripping class 20, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). For diagnostics, it provides a thermal overload alarm to be managed with an additional function module (to be ordered separately) and a test push button for overload simulation. To be used with a 110-240V AC \/ 110-220V DC voltage for the control of the starter (through the control terminals A1\/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLUCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eAdvanced control unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003eMotor control\u003cbr\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Specific Application\u003c\/td\u003e\n\u003ctd\u003eBasic protection and advanced functions, communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emain function available\u003c\/td\u003e\n\u003ctd\u003eEarth fault protection\u003cbr\u003eProtection against phase failure and phase imbalance\u003cbr\u003eManual reset\u003cbr\u003eProtection against overload and short-circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct compatibility\u003c\/td\u003e\n\u003ctd\u003ePower base LUB32\u003cbr\u003ePower base LUB38\u003cbr\u003ePower base LUB320\u003cbr\u003ePower base LUB380\u003cbr\u003eReversing contactor breaker LU2B32FU\u003cbr\u003eReversing contactor breaker LU2B38FU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork frequency\u003c\/td\u003e\n\u003ctd\u003e40...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad type\u003c\/td\u003e\n\u003ctd\u003e3-phase motor self-cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-41\u003cbr\u003eAC-43\u003cbr\u003eAC-44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e7.5 kW 400...440 V AC 50\/60 Hz\u003cbr\u003e9 kW 500 V AC 50\/60 Hz\u003cbr\u003e15 kW 690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003erated motor current adjustment range\u003c\/td\u003e\n\u003ctd\u003e4.5â¦18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal overload class\u003c\/td\u003e\n\u003ctd\u003eClass 20 40â¦60 Hz -13â¦158 Â°F (-25â¦70 Â°C) IEC 60947-6-2\u003cbr\u003eClass 20 40â¦60 Hz -13â¦158 Â°F (-25â¦70 Â°C) UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping threshold\u003c\/td\u003e\n\u003ctd\u003e14.2 x Ir +\/- 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase failure sensitivity\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e110...240 V AC\u003cbr\u003e110...220 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e88...264 V AC 110...240 V in operation\u003cbr\u003e88...242 V DC 110...220 V in operation\u003cbr\u003e55 V AC 110...240 V drop-out\u003cbr\u003e55 V DC 110...220 V drop-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical current consumption\u003c\/td\u003e\n\u003ctd\u003e280 mA 110...240 V AC I maximum while closing with LUB32\u003cbr\u003e280 mA 110...240 V AC I maximum while closing with LUB38\u003cbr\u003e280 mA 110...220 V DC I maximum while closing with LUB32\u003cbr\u003e280 mA 110...220 V DC I maximum while closing with LUB38\u003cbr\u003e25 mA 110...240 V AC I rms sealed with LUB32\u003cbr\u003e25 mA 110...240 V AC I rms sealed with LUB38\u003cbr\u003e25 mA 110...220 V DC I rms sealed with LUB32\u003cbr\u003e25 mA 110...220 V DC I rms sealed with LUB38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e3 W control circuit with LUB32\u003cbr\u003e3 W control circuit with LUB38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e35 ms opening with LUB32 control circuit\u003cbr\u003e35 ms opening with LUB38 control circuit\u003cbr\u003e50 ms closing with LUB32 control circuit\u003cbr\u003e50 ms closing with LUB38 control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset\u003c\/td\u003e\n\u003ctd\u003eManual reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 60947-6-2\u003cbr\u003eIEC 60947-6-2\u003cbr\u003eUL 60947-4-1, with phase barrier\u003cbr\u003eCSA C22.2 No 60947-4-1, with phase barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003cbr\u003eUL\u003cbr\u003eCSA\u003cbr\u003eCCC\u003cbr\u003eEAC\u003cbr\u003eASEFA\u003cbr\u003eATEX\u003cbr\u003eMarine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e690 V IEC 60947-6-2\u003cbr\u003e600 V UL 60947-4-1\u003cbr\u003e600 V CSA C22.2 No 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV IEC 60947-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe separation of circuit\u003c\/td\u003e\n\u003ctd\u003e400 V SELV between the control and auxiliary circuits IEC 60947-1\u003cbr\u003e400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixing mode\u003c\/td\u003e\n\u003ctd\u003ePlug-in (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.8 in (45 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e2.6 in (66 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e2.4 in (60 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLUCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840659443934,"sku":"LUCD18FU-Sealed","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Never Used Surplus","offer_id":42694272418014,"sku":"LUCD18FU","price":426.95,"currency_code":"EUR","in_stock":true},{"title":"Used","offer_id":42694272450782,"sku":"LUCD18FU-Used","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LUCD18FU.jpg?v=1650048424","url":"https:\/\/plc-direct.com\/en-de\/products\/lucd18fu","provider":"PLC Direct","version":"1.0","type":"link"}