{"product_id":"ltmev40fm","title":"LTMEV40FM Schneider","description":"\u003cp\u003eTeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. TeSys T has a number of components that increase the flexibility of the system. This expansion module adds functionalities to the TeSys T controller. It adds voltage mesurement between phases up to 690 V nominal and 4 additional inputs. Module has 4 discrete logic inputs. 120 to 240 VAC is used to power the module. Module has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003eTeSys T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLTME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eExtension module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Application\u003c\/td\u003e\n\u003ctd\u003eEquipment monitoring and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange compatibility\u003c\/td\u003e\n\u003ctd\u003eTeSys TeSys T LTMR motor controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003eVia the controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e690 V EN\/IEC 60947-1\u003cbr\u003e690 V CSA C22.2 No 14\u003cbr\u003e690 V UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e4 kV supply, inputs and outputs EN\/IEC 60947-4-1\u003cbr\u003e6 kV current or voltage measurement circuit EN\/IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic input number\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current\u003c\/td\u003e\n\u003ctd\u003e3.1 mA 100 V\u003cbr\u003e7.5 mA 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent state 0 guaranteed\u003c\/td\u003e\n\u003ctd\u003eLogic input 0...40 V 2...15 mA 25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent state 1 guaranteed\u003c\/td\u003e\n\u003ctd\u003eLogic input 79...264 V \u0026lt;= 15 mA 25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum output switching frequency\u003c\/td\u003e\n\u003ctd\u003e2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e1800 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContacts type and composition\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering type\u003c\/td\u003e\n\u003ctd\u003eImbalance voltage\u003cbr\u003eActive power P, P1, P2, P3\u003cbr\u003eCalculated active and reactive energy (+\/- W.h, +\/- VAR.h)\u003cbr\u003eVoltage U21, U32, U13, V1, V2, V3\u003cbr\u003eReactive power Q, Q1, Q2, Q3\u003cbr\u003eFrequency\u003cbr\u003ePower factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003e1 % voltage 100...830 V)\u003cbr\u003e3 % power factor\u003cbr\u003e5 % active and reactive power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection pitch\u003c\/td\u003e\n\u003ctd\u003e0.20 in (5.08 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit connector 1 0.0004â¦0.004 inÂ² (0.25â¦2.5 mmÂ²) AWG 24...AWG 14)flexible with cable end\u003cbr\u003eControl circuit connector 1 0.0003â¦0.004 inÂ² (0.2â¦2.5 mmÂ²) AWG 24...AWG 14)flexible without cable end\u003cbr\u003eControl circuit connector 1 0.0004â¦0.004 inÂ² (0.25â¦2.5 mmÂ²) AWG 24...AWG 14)flexible without cable end\u003cbr\u003eControl circuit connector 1 0.0003â¦0.004 inÂ² (0.2â¦2.5 mmÂ²) AWG 24...AWG 14)solid without cable end\u003cbr\u003eControl circuit connector 2 0.0003â¦0.002 inÂ² (0.2â¦1 mmÂ²) AWG 24...AWG 14)flexible with cable end\u003cbr\u003eControl circuit connector 2 0.0003â¦0.002 inÂ² (0.2â¦1.5 mmÂ²) AWG 24...AWG 14)flexible without cable end\u003cbr\u003eControl circuit connector 2 0.0008â¦0.002 inÂ² (0.5â¦1.5 mmÂ²) AWG 24...AWG 14)flexible without cable end\u003cbr\u003eControl circuit connector 2 0.0003â¦0.002 inÂ² (0.2â¦1 mmÂ²) AWG 24...AWG 14)solid without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit: 4.4â¦5.3 lbf.in (0.5â¦0.6 N.m) flat screwdriver 0.1 in (3 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epollution degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd\u003eElectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN\/IEC 61000-4-2\u003cbr\u003eFast transients immunity test (other circuits), level 3, 2 kV, conforming to EN\/IEC 61000-4-4\u003cbr\u003eFast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN\/IEC 61000-4-4\u003cbr\u003eConducted RF disturbances, 10 V, conforming to EN\/IEC 61000-4-6\u003cbr\u003eControl circuit: surges (serial mode), 1 kV, conforming to EN\/IEC 61000-4-5\u003cbr\u003eCommunication: surges (common mode), 2 kV, conforming to EN\/IEC 61000-4-5\u003cbr\u003eVoltage inputs: surges (serial mode), 2 kV, conforming to EN\/IEC 61000-4-5\u003cbr\u003eVoltage inputs: surges (common mode), 4 kV, conforming to EN\/IEC 61000-4-5\u003cbr\u003eControl circuit: surges (common mode), 2 kV, conforming to EN\/IEC 61000-4-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e1.8 in (45 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e2.4 in (61 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e4.8 in (120.7 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.46 lb(US) (0.21 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLTME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840653775070,"sku":"LTMEV40FM-Sealed","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Never Used Surplus","offer_id":32436195033219,"sku":"LTMEV40FM","price":501.95,"currency_code":"EUR","in_stock":true},{"title":"Used","offer_id":42379456610526,"sku":"LTMEV40FM-Used","price":462.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LTMEV40FM.jpg?v=1640701533","url":"https:\/\/plc-direct.com\/en-de\/products\/ltmev40fm","provider":"PLC Direct","version":"1.0","type":"link"}