{"product_id":"lc2d65ab7","title":"LC2D65AB7 Schneider Electric","description":"\u003cp\u003eTeSys Deca reversing contactor, 3 poles (3NO), for motor control applications up to 65A\/590V AC-3 (30kW@400V). Rated 65A AC-3 30kW@400V, it includes a 24V 50\/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. It provides 24V 50\/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), power connection by EverLink BTR screw connectors, control by screw clamp terminals. For operating rates until 3600 cycles\/hour and environments until 60Â°C, it procures high reliability and durability. Compact (119mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 24V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 65A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003cbr\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003eTeSys D\u003cbr\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eReversing contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eResistive load\u003cbr\u003eMotor control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-3\u003cbr\u003eAC-1\u003cbr\u003eAC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice presentation\u003c\/td\u003e\n\u003ctd\u003ePreassembled with reversing power busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epower pole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit \u0026lt;= 690 V AC 25...400 Hz\u003cbr\u003ePower circuit \u0026lt;= 300 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e80 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-1 for power circuit\u003cbr\u003e65 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3 for power circuit\u003cbr\u003e65 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3e for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e18.5 kW at 220...230 V AC 50 Hz\u003cbr\u003e30 kW at 380...400 V AC 50 Hz\u003cbr\u003e37 kW at 415...440 V AC 50 Hz\u003cbr\u003e37 kW at 500 V AC 50 Hz\u003cbr\u003e37 kW at 660...690 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emotor power HP (UL \/ CSA)\u003c\/td\u003e\n\u003ctd\u003e40 hp at 460\/480 V AC 60 Hz for 3 phase motors\u003cbr\u003e5 hp at 115 V AC 60 Hz for 1 phase motors\u003cbr\u003e10 hp at 230\/240 V AC 60 Hz for 1 phase motors\u003cbr\u003e20 hp at 200\/208 V AC 60 Hz for 3 phase motors\u003cbr\u003e20 hp at 230\/240 V AC 60 Hz for 3 phase motors\u003cbr\u003e50 hp at 575\/600 V AC 60 Hz for 3 phase motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e10 A (at 140 Â°F (60 Â°C)) for signalling circuit\u003cbr\u003e80 A (at 140 Â°F (60 Â°C)) for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e140 A AC for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e250 A DC for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e1000 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e1000 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e520 A 104 Â°F (40 Â°C) - 10 s for power circuit\u003cbr\u003e900 A 104 Â°F (40 Â°C) - 1 s for power circuit\u003cbr\u003e110 A 104 Â°F (40 Â°C) - 10 min for power circuit\u003cbr\u003e260 A 104 Â°F (40 Â°C) - 1 min for power circuit\u003cbr\u003e100 A - 1 s for signalling circuit\u003cbr\u003e120 A - 500 ms for signalling circuit\u003cbr\u003e140 A - 100 ms for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e10 A gG for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e125 A gG at \u0026lt;= 690 V coordination type 1 for power circuit\u003cbr\u003e125 A gG at \u0026lt;= 690 V coordination type 2 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e1.5 mOhm - Ith 80 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit 690 V IEC 60947-4-1\u003cbr\u003ePower circuit 600 V CSA\u003cbr\u003ePower circuit 600 V UL\u003cbr\u003eSignalling circuit 690 V IEC 60947-1\u003cbr\u003eSignalling circuit 600 V CSA\u003cbr\u003eSignalling circuit 600 V UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e1.45 Mcycles 65 A AC-3 \u0026lt;= 440 V\u003cbr\u003e1.4 Mcycles 80 A AC-1 \u0026lt;= 440 V\u003cbr\u003e1.45 Mcycles 65 A AC-3e \u0026lt;= 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e9.6 W AC-1\u003cbr\u003e6.3 W AC-3\u003cbr\u003e6.3 W AC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront cover\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterlocking type\u003c\/td\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eRail\u003cbr\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No 14\u003cbr\u003eEN 60947-4-1\u003cbr\u003eEN 60947-5-1\u003cbr\u003eIEC 60947-4-1\u003cbr\u003eIEC 60947-5-1\u003cbr\u003eUL 508\u003cbr\u003eIEC 60335-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eUL\u003cbr\u003eCSA\u003cbr\u003eRINA\u003cbr\u003eGOST\u003cbr\u003eCCC\u003cbr\u003eDNV\u003cbr\u003eLROS (Lloyds register of shipping)\u003cbr\u003eGL\u003cbr\u003eBV\u003cbr\u003eUKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)flexible without cable end\u003cbr\u003eControl circuit screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)flexible without cable end\u003cbr\u003eControl circuit screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)flexible with cable end\u003cbr\u003eControl circuit screw clamp terminals 2 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²)flexible with cable end\u003cbr\u003eControl circuit screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)solid\u003cbr\u003eControl circuit screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)solid\u003cbr\u003ePower circuit EverLink BTR screw connectors 1 0.002â¦0.05 inÂ² (1â¦35 mmÂ²)flexible without cable end\u003cbr\u003ePower circuit EverLink BTR screw connectors 2 0.002â¦0.04 inÂ² (1â¦25 mmÂ²)flexible without cable end\u003cbr\u003ePower circuit EverLink BTR screw connectors 1 0.002â¦0.05 inÂ² (1â¦35 mmÂ²)flexible with cable end\u003cbr\u003ePower circuit EverLink BTR screw connectors 2 0.002â¦0.04 inÂ² (1â¦25 mmÂ²)flexible with cable end\u003cbr\u003ePower circuit EverLink BTR screw connectors 1 0.002â¦0.05 inÂ² (1â¦35 mmÂ²)solid\u003cbr\u003ePower circuit EverLink BTR screw connectors 2 0.002â¦0.04 inÂ² (1â¦25 mmÂ²)solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ã 6 mm\u003cbr\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2\u003cbr\u003ePower circuit 70.8 lbf.in (8 N.m) EverLink BTR screw connectors 0.04â¦0.05 inÂ² (25â¦35 mmÂ²) hexagonal 0.2 in (4 mm)\u003cbr\u003ePower circuit 44.3 lbf.in (5 N.m) EverLink BTR screw connectors 0.002â¦0.04 inÂ² (1â¦25 mmÂ²) hexagonal 0.2 in (4 mm)\u003cbr\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2\u003cbr\u003ePower circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e4...19 ms opening\u003cbr\u003e12...26 ms closing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e6 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h 140 Â°F (60 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eWithout built-in suppressor module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e0.3...0.6 Uc (-40â¦158 Â°F (-40â¦70 Â°C)):drop-out AC 50\/60 Hz\u003cbr\u003e0.8...1.1 Uc (-40â¦140 Â°F (-40â¦60 Â°C)):operational AC 50 Hz\u003cbr\u003e0.85...1.1 Uc (-40â¦140 Â°F (-40â¦60 Â°C)):operational AC 60 Hz\u003cbr\u003e1...1.1 Uc (140â¦158 Â°F (60â¦70 Â°C)):operational AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in VA\u003c\/td\u003e\n\u003ctd\u003e140 VA 60 Hz cos phi 0.75 (at 68 Â°F (20 Â°C))\u003cbr\u003e160 VA 50 Hz cos phi 0.75 (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e13 VA 60 Hz cos phi 0.3 (at 68 Â°F (20 Â°C))\u003cbr\u003e15 VA 50 Hz cos phi 0.3 (at 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e4â¦5 W 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003eMechanically linked 1 NO + 1 NC IEC 60947-5-1\u003cbr\u003eMirror contact 1 NC IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignalling circuit frequency\u003c\/td\u003e\n\u003ctd\u003e25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-overlap time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms on de-energisation between NC and NO contact\u003cbr\u003e1.5 ms on energisation between NC and NO contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840641880286,"sku":"LC2D65AB7-Sealed","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Never Used Surplus","offer_id":42694207471838,"sku":"LC2D65AB7","price":958.95,"currency_code":"EUR","in_stock":true},{"title":"Used","offer_id":42694207504606,"sku":"LC2D65AB7-Used","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LC2D65AB7.jpg?v=1650047506","url":"https:\/\/plc-direct.com\/en-de\/products\/lc2d65ab7","provider":"PLC Direct","version":"1.0","type":"link"}