{"product_id":"lc1g185ehen","title":"LC1G185EHEN Schneider","description":"\u003cp\u003eTeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 185A 110kW@440V. It provides a 48-130V AC\/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60Â°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables\/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25Â°C to 60Â°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 108mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified (CE,CB,CCC,cULus,EAC,KC,RCM,Marine). Unique QR code provides quick access to complete product data.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003ePower switching\u003cbr\u003eMotor control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-1\u003cbr\u003eAC-3\u003cbr\u003eAC-3e\u003cbr\u003eAC-4\u003cbr\u003eAC-5a\u003cbr\u003eAC-5b\u003cbr\u003eAC-6a\u003cbr\u003eAC-6b\u003cbr\u003eAC-8b\u003cbr\u003eAC-8a\u003cbr\u003eDC-1\u003cbr\u003eDC-3\u003cbr\u003eDC-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e305 A (at \u0026lt;104 Â°F (40 Â°C)) at \u0026lt;= 1000 V AC-1\u003cbr\u003e185 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e48...130 V AC 50\/60 Hz\u003cbr\u003e48...130 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003eOperational: 0.8 Uc Min...1.1 Uc Max (at \u0026lt;140 Â°F (60 Â°C))\u003cbr\u003eDrop-out: 0.1 Uc Max...0.45 Uc Min (at \u0026lt;140 Â°F (60 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e305 A (at 104 Â°F (40 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e1610 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e1.5 kA - 10 s\u003cbr\u003e0.92 kA - 30 s\u003cbr\u003e0.74 kA - 1 min\u003cbr\u003e0.5 kA - 3 min\u003cbr\u003e0.4 kA - 10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e200 A aM at \u0026lt;= 440 V for motor\u003cbr\u003e160 A aM at \u0026lt;= 690 V for motor\u003cbr\u003e315 A gG at \u0026lt;= 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e0.00017 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e20 W AC-1 - Ith 305 A\u003cbr\u003e6 W AC-3 - Ith 185 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e55 kW at 230 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e90 kW at 400 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e90 kW at 415 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e110 kW at 440 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e110 kW at 500 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e110 kW at 690 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e75 kW at 1000 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e55 kW at 230 V AC 50\/60 Hz (AC-3)\u003cbr\u003e90 kW at 400 V AC 50\/60 Hz (AC-3)\u003cbr\u003e90 kW at 415 V AC 50\/60 Hz (AC-3)\u003cbr\u003e110 kW at 440 V AC 50\/60 Hz (AC-3)\u003cbr\u003e110 kW at 500 V AC 50\/60 Hz (AC-3)\u003cbr\u003e110 kW at 690 V AC 50\/60 Hz (AC-3)\u003cbr\u003e75 kW at 1000 V AC 50\/60 Hz (AC-3)\u003cbr\u003e55 kW at 230 V AC 50\/60 Hz (AC-4)\u003cbr\u003e90 kW at 400 V AC 50\/60 Hz (AC-4)\u003cbr\u003e90 kW at 415 V AC 50\/60 Hz (AC-4)\u003cbr\u003e100 kW at 440 V AC 50\/60 Hz (AC-4)\u003cbr\u003e110 kW at 500 V AC 50\/60 Hz (AC-4)\u003cbr\u003e110 kW at 690 V AC 50\/60 Hz (AC-4)\u003cbr\u003e75 kW at 1000 V AC 50\/60 Hz (AC-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Horse Power Rating\u003c\/td\u003e\n\u003ctd\u003e50 hp at 200\/208 V 60 Hz\u003cbr\u003e60 hp at 230\/240 V 60 Hz\u003cbr\u003e125 hp at 460\/480 V 60 Hz\u003cbr\u003e150 hp at 575\/600 V 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e2310 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 400000 cycles contactor with nominal load EN\/ISO 13849-1\u003cbr\u003eB10d = 3000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e8 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einrush power in VA (50\/60 Hz, AC)\u003c\/td\u003e\n\u003ctd\u003e640 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einrush power in W (DC)\u003c\/td\u003e\n\u003ctd\u003e445 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehold-in power consumption in VA (50\/60 Hz, AC)\u003c\/td\u003e\n\u003ctd\u003e18.7 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehold-in power consumption in W (DC)\u003c\/td\u003e\n\u003ctd\u003e7.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e40...70 ms closing\u003cbr\u003e15...50 ms opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e600 cyc\/h AC-3\u003cbr\u003e600 cyc\/h AC-3e\u003cbr\u003e300 cyc\/h AC-1\u003cbr\u003e150 cyc\/h AC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bar 2 - busbar cross section: 25 x 6 mm\u003cbr\u003ePower circuit: lugs-ring terminals 1 0.3 inÂ² (185 mmÂ²)\u003cbr\u003ePower circuit: bolted connection\u003cbr\u003eControl circuit: push-in 1 0.0003â¦0.004 inÂ² (0.2â¦2.5 mmÂ²) - cable stiffness: solid stranded without cable end\u003cbr\u003eControl circuit: push-in 1 0.0004â¦0.004 inÂ² (0.25â¦2.5 mmÂ²) - cable stiffness: flexible with cable end\u003cbr\u003eControl circuit: push-in 2 0.0008â¦0.002 inÂ² (0.5â¦1.0 mmÂ²) with cable end\u003cbr\u003eControl circuit: push-in 0.001â¦0.004 inÂ² (0.75â¦2.5 mmÂ²) - cable stiffness: solid stranded without cable end\u003cbr\u003eControl circuit: push-in 0.001â¦0.004 inÂ² (0.75â¦2.5 mmÂ²) - cable stiffness: flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection pitch\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-4-1\u003cbr\u003eEN\/IEC 60947-5-1\u003cbr\u003eUL 60947-4-1\u003cbr\u003eCSA C22.2 No 60947-4-1\u003cbr\u003eJIS C8201-4-1\u003cbr\u003eJIS C8201-5-1\u003cbr\u003eIEC 60335-1:Clause 30.2\u003cbr\u003eIEC 60335-2-40:Annex JJ\u003cbr\u003eUL 60335-1\u003cbr\u003eUL 60335-2-40:Annex JJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCB Scheme\u003cbr\u003eCCC\u003cbr\u003ecULus\u003cbr\u003eEAC\u003cbr\u003eCE\u003cbr\u003eUKCA\u003cbr\u003eEU-RO-MR by DNV-GL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e159.3 lbf.in (18 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e7.6 in (193 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e4.3 in (108 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e7.6 in (193 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e7.7 lb(US) (3.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840630149342,"sku":"LC1G185EHEN-Sealed","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Never Used Surplus","offer_id":46487518576862,"sku":"LC1G185EHEN","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Used","offer_id":46487518642398,"sku":"LC1G185EHEN-Used","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_2a235e06-daf6-4da7-a53f-c6b39dda1d02.png?v=1753948943","url":"https:\/\/plc-direct.com\/en-de\/products\/lc1g185ehen","provider":"PLC Direct","version":"1.0","type":"link"}