{"product_id":"lc1f4004","title":"LC1F4004 Schneider Electric","description":"\u003cp\u003eTeSys F contactor, 4 poles (4NO), 500A\/1000V AC-1, for non-inductive load applications. Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles\/hour and environments until 55Â°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS\/REACh).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eproduct name\u003c\/td\u003e\n\u003ctd\u003eTeSys F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eResistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epower pole contact composition\u003c\/td\u003e\n\u003ctd\u003e4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1000 V AC 50\/60 Hz\u003cbr\u003e \u0026lt;= 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e500 A 104 Â°F (40 Â°C)) \u0026lt;= 440 V AC AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e48...1000 V AC 40...400 Hz with LX1\/LX9 coil\u003cbr\u003e48...440 V DC with LX4 coil\u003cbr\u003e100...250 V AC 50\/60 Hz with LXE coil\u003cbr\u003e100...380 V DC with LXE coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e500 A (at 104 Â°F (40 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e4000 A AC conforming to IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e3200 A conforming to IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e3600 A 104 Â°F (40 Â°C) - 10 s\u003cbr\u003e2400 A 104 Â°F (40 Â°C) - 30 s\u003cbr\u003e1700 A 104 Â°F (40 Â°C) - 1 min\u003cbr\u003e1200 A 104 Â°F (40 Â°C) - 3 min\u003cbr\u003e1000 A 104 Â°F (40 Â°C) - 10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e400 A aM at \u0026lt;= 440 V\u003cbr\u003e500 A gG at \u0026lt;= 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e0.26 mOhm - Ith 500 A 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V IEC 60947-4-1\u003cbr\u003e 1500 V VDE 0110 group C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e65 W AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003eOperational: 0.85...1.1 Uc AC 40...400 Hz with LX1\/LX9 coil\u003cbr\u003eDrop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1\/LX9 coil\u003cbr\u003eOperational: 0.85...1.1 Uc DC with LX4 coil\u003cbr\u003eDrop-out: 0.2...0.35 Uc DC with LX4 coil\u003cbr\u003eOperational: 85...275 V AC 50\/60 Hz with LXE coil\u003cbr\u003eDrop-out: 0...60 V AC 50\/60 Hz with LXE coil\u003cbr\u003eOperational: 85...418 V DC with LXE coil\u003cbr\u003eDrop-out: 0...45 V DC with LXE coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e14 W\u003cbr\u003e2.2â¦5.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e40...75 ms closing with LX1\/LX9 coil\u003cbr\u003e100...170 ms opening with LX1\/LX9 coil\u003cbr\u003e50...60 ms closing with LX4 coil\u003cbr\u003e45...60 ms opening with LX4 coil\u003cbr\u003e40...80 ms closing with LXE coil\u003cbr\u003e6...54 ms opening with LXE coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eJIS C8201-4-1\u003cbr\u003eIEC 60947-4-1\u003cbr\u003eIEC 60947-1\u003cbr\u003eEN 60947-4-1\u003cbr\u003eEN 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCB\u003cbr\u003eABS\u003cbr\u003eDNV\u003cbr\u003eRMRoS\u003cbr\u003eLROS (Lloyds register of shipping)\u003cbr\u003eBV\u003cbr\u003eRINA\u003cbr\u003eUL\u003cbr\u003eCSA\u003cbr\u003eUKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003ePower circuit bar 2 30 x 5 mm\u003cbr\u003ePower circuit lugs-ring terminals 2 0.2 inÂ² (150 mmÂ²)\u003cbr\u003eControl circuit screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)flexible without cable end\u003cbr\u003eControl circuit screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)flexible with cable end\u003cbr\u003eControl circuit screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)flexible with cable end\u003cbr\u003eControl circuit screw clamp terminals 2 0.002â¦0.004 inÂ² (1â¦2.5 mmÂ²)solid without cable end\u003cbr\u003eControl circuit screw clamp terminals 1 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)\u003cbr\u003eControl circuit screw clamp terminals 2 0.002â¦0.006 inÂ² (1â¦4 mmÂ²)\u003cbr\u003eControl circuit screw clamp terminals 1.0 0.0003â¦0.004 inÂ² (0.2â¦2.5 mmÂ²)flexible without cable end\u003cbr\u003eControl circuit screw clamp terminals 1.0 0.0004â¦0.004 inÂ² (0.25â¦2.5 mmÂ²)flexible with cable end\u003cbr\u003eControl circuit screw clamp terminals 1.0 0.0003â¦0.004 inÂ² (0.2â¦2.5 mmÂ²)solid without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003ePower circuit 309.8 lbf.in (35 N.m)\u003cbr\u003eControl circuit 10.6 lbf.in (1.2 N.m)\u003cbr\u003eControl circuit 5.3 lbf.in (0.6 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e10 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in VA\u003c\/td\u003e\n\u003ctd\u003e1000â¦1150 VA, 40...400 Hz cos phi 0.9 (at 68 Â°F (20 Â°C))with LX1\/LX9 coil\u003cbr\u003e920â¦1140 VA (at 68 Â°F (20 Â°C))with LX4 coil\u003cbr\u003e360â¦470 VA, 50\/60 Hz cos phi 0.5 (at 68 Â°F (20 Â°C))with LXE coil\u003cbr\u003e410â¦450 VA (at 68 Â°F (20 Â°C))with LXE coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in VA\u003c\/td\u003e\n\u003ctd\u003e12â¦18 VA, 40...400 Hz cos phi 0.9 (at 68 Â°F (20 Â°C))with LX1\/LX9 coil\u003cbr\u003e4â¦7.5 VA (at 68 Â°F (20 Â°C))with LX4 coil\u003cbr\u003e4.5â¦7.0 VA, 50\/60 Hz cos phi 0.5 (at 68 Â°F (20 Â°C))with LXE coil\u003cbr\u003e2.5â¦4.0 VA (at 68 Â°F (20 Â°C))with LXE coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e2400 cyc\/h 131 Â°F (55 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLC1F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840628838622,"sku":"LC1F4004-Sealed","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Never Used Surplus","offer_id":42680807456990,"sku":"LC1F4004","price":2434.95,"currency_code":"EUR","in_stock":true},{"title":"Used","offer_id":42680807489758,"sku":"LC1F4004-Used","price":1521.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/products\/LC1F4004.jpg?v=1649787356","url":"https:\/\/plc-direct.com\/en-de\/products\/lc1f4004","provider":"PLC Direct","version":"1.0","type":"link"}